After  five  seconds  of  selecting  a  level  for  this  function,  it  will  be  stored  in  memory.  This  means 
that, in case you turn the splitter off, the Brightness/Gain level set in the equipment when you turn 
it on again will be the last one you selected before turning the splitter off. 

When the splitter is recording the set level in memory, the White Balance LED indicator (central 
position) will blink. 

5.3 WHITE BALANCE FUNCTION 

The  White  Balance  function  allows  the  equipment  to  perform  an  internal  calibration  to 
compensate the differences in color temperatures of different light sources, ensuring reliable color 
reproduction. Since this function adjusts the camera parameters for a particular light source, the 
White  Balance  procedure  must  be  performed  each  time  the  light  source  to  be  used  with  the 
equipment is changed. 

To get the White Balance, focus on a completely white and illuminated image with light intensity 
at maximum power and press the White Balance button for approximately 3 seconds.  

This White  Balance  remains  stored  in  memory  even  when  the  camera  is  turned  off.  During  the 
White Balance setting, the White Balance indicator flashes to indicate that  the White Balance is 
being performed, then when the White Balance button is not pressed the LED indicator remains 
off.  

Only if the White Balance is set correctly, reliable color reproduction is guaranteed. 

Perform a new White Balance if the light source is changed. 

Always perform the White Balance with the light source that will be used to carry out the 
procedure afterwards. 

6.  MAINTENANCE 

6.1 CLEANING 

Before cleaning the 3D HD Splitter, disconnect the power  cable from the electric power 
supply. 

Do not sterilize nor immerse in liquid the device or any of its accessories or parts. 

 

CLEANING OF EXTERNAL SURFACES 

To  clean  the  outer  surfaces  of  the  device  only  use  a  soft  cloth  dampened  in  mild  detergent  or 
soap.  Only  use  adequate  cleaning  products  prepared  for  electrical  equipment  following  the 
product’s instructions. 

We recommend cleaning the external surfaces once every 15 days. 

Never use flammable products, especially alcohol, when the unit is hot. 

While cleaning, be careful not to let water or humidity get into the equipment. 

Do not use any abrasive agent.

 

 

Содержание PROCAM HD 3D

Страница 1: ...thout previous written authorization from ECLERIS Neither can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modif...

Страница 2: ...3 3 COMPONENTS 5 3 3 1 MAIN UNIT FRONT PANEL 6 3 3 2 MAIN UNIT REAR PANEL 6 3 3 3 3D SPLITTER SIDE CONTROLS 6 4 INSTALLATION AND SET UP 7 5 FUNCTIONS 9 5 1 WINDOWS FUNCTION 10 5 2 BRIGHTNESS GAIN FUNC...

Страница 3: ...llowing the instructions or not observing the following criteria Keep the equipment out of children reach Do not install the equipment next to heat sources such as heaters Install the equipment on a f...

Страница 4: ...any of the following Inadequate use of the equipment Failure to use the instruction manual Bad maintenance and care of the equipment Repair or manipulation by unauthorized personnel personal or materi...

Страница 5: ...icroscopes and colposcopes or on a flat surface 3 2 INTENDED USER Any health professional or technician who has basic knowledge on how to operate a stereoscopic microscope People with a large visual i...

Страница 6: ...3 1 MAIN UNIT FRONT PANEL 1 Video Input for 3D Splitter cable 2 ON OFF button 3 3 2 MAIN UNIT REAR PANEL 1 Video Output 3D HD 2 Video Output 2D HD 3 Power Input 4 Equipotential pin 3 3 3 3D SPLITTER...

Страница 7: ...ored to the bottom side of the light source The base of the light source has two holes where the head of the screws of the Ecleris 3D main unit shall be introduced Once the head of the anchor screws a...

Страница 8: ...and the binocular and adjust the fixing screw 7 Turn ON the monitor and select the active 3D function or 2D if you prefer and turn ON the main unit of the splitter 8 Perform a White Balance if it is t...

Страница 9: ...cedure until you can focus correctly on all magnifications 10 Once you have performed the para focalization with the microscope through the eyepieces proceed to check the focusing of the image on the...

Страница 10: ...elected If the image after adjusting the Windows level remains unchanged the lighting levels are optimal and there is no need to adjust the Windows however any change of lighting will be automatically...

Страница 11: ...oximately 3 seconds This White Balance remains stored in memory even when the camera is turned off During the White Balance setting the White Balance indicator flashes to indicate that the White Balan...

Страница 12: ...f plastic where the fuses are placed With the help of a screwdriver and performing light pressure remove the cover to replace the damaged fuse 3 Remove the damaged fuses and replace them immediately u...

Страница 13: ...en content The device is provided with a connectable power cable that assures proper electrical isolation 8 TROUBLESHOOTING The following table indicates the most common problems and their solutions P...

Страница 14: ...age is out of focus on the monitor Camera inside HD Splitter not focused Adjust the individual focus of the HD Splitter as described on INSTALLATION AND SET UP Incorrect colors on monitor White Balanc...

Страница 15: ...be sent for repair The following information should be sent with the product Owner s name Owner s address Person to contact and a telephone number Product serial number Problem description The shipme...

Отзывы: