34
98
s sleep time 1!
Set switcher sleep time (no signal to standby mode time)
(1: OFF, 2: 15seconds, 3: 1minutes, 4: 5minutes, 5:
15minutes, 6: 60minutes)
99
r osd time!
Get OSD time out
100
s osd time 1!
Set OSD time out
(1: 5seconds, 2: 10seconds, 3: 15seconds,
4: 20seconds, 5: 25seconds, 6: 30seconds)
The same command strings can be sent using a
standard TCP/IP connection to the
port indicated in Network Settings, or using the standard Telnet port 23.
The strings
can be tested using a TCP/IP client terminal like Hercules: just open a connection using
the switcher IP address and the port indicated in Network Settings and send the
command string followed by “Carriage Return” <CR>.
13.
Web GUI Control
Switcher can be controlled with web interface, just type VEO-SWM45’s IP address in
address bar in web browser.
If the IP address is unknown,
there are two methods to
obtain it:
UIn OSD Menu by using the IR remote control.
Using RS-232 command string.
If the IP address is 192.168.1.100 (default) just type:
http://192.168.1.100