background image

 
 

 

PRE

CA
U

TIO

N

PA

CK
A

G

E CO
NT
ENT

D

ES

CRI
PT

IO

 &

 

FEA
TU

R

ES

 

PA

NE
L F

U

NCT

O

N

INS
TA

LL

 &

 CO
NN
ECT

 

STA
R

T-

UP
 &

 O

PE

R

ATI
O

N

 
TEC

H

N

IC

A

D

A

TA

 

W

AR
R

AN
TY

 &

 

EN

V

IRO
NME

NT
 

1.2

 

Key Safety Directions 

1.

 

Read the following directions.

 

2.

 

Keep the following directions. 

3.

 

Heed all warnings. 

4.

 

Follow all directions. 

5.

 

Do not use this device in proximity to 
water. 

6.

 

Clean only with a dry cloth. 

7.

 

Do not block any ventilation 
openings. Install in accordance with 
the manufacturer’s instructions. 

8.

 

Do not install near any heat sources 
such as radiators, heat registers, 
stoves, or other devices (including 
amplifiers) that may release heat. 

9.

 

Do not defeat the safety purpose of 
the polarized or grounding type 
plug. A polarized plug has two 
blades, being one wider than the 
other. A grounding type plug has 
two blades and a third grounding 
prong. The wide blade or the third 
prong are provided for your safety. If 
the provided plug does not fit into 
your outlet, contact a qualified 
electrician for a replacement of the 
obsolete outlet. 

10.

 

Protect the power cord from being 
walked on or pinched, particularly at 
the plugs, convenience receptacles, 
and at the point of exit from the 
device. 

11.

 

Only use attachments/accessories 
specified by the manufacturer. 

12.

 

Unplug the device during lightening 
sorts or when unused for long periods of 
time. 

13.

 

Refer all servicing to qualified personnel. 
Servicing is required when the device 
has been damaged in any way, such as 
power supply cord or plug damage, 
liquid spillage or objects onto the device, 
the device has been exposed to rain or 
humidity, does not operate normally, or 
has been dropped.

 

14.

 

Disconnecting from mains: When 
switching off the POWER switch, all the 
functions and light indicators of the unit 
will be stopped, but fully disconnecting 
the device from mains is done by 
unplugging the power cable from the 
mains input socket, therefore, it should 
always remain easily accessible  

15.

 

Equipment is connected to a socket-
outlet with an earthing connection by 
means of a power cord. 

16.

 

The marking information is located at the 
bottom of the unit. 

17.

 

The device shall not be exposed to 
dripping or splashing liquids, and no 
liquid-filled objects, such as a filled up 
glass, shall be placed on top of the 
device.

1.3

 

Cleaning Directions 

Clean the unit with a soft, dry clean cloth

 or slightly wet with water and neutral liquid 

soap only, then dry it with a clean cloth. Be careful that water never gets into the unit through 
any hole. Never use alcohol, benzine, solvents or abrasive substances to clean this unit. 

NEEC AUDIO BARCELONA, S.L.

 accepts no liability for any damage that may be caused to 

people, animal, or objects due to failure to comply with the warnings above.

 

 

Содержание HADA Series

Страница 1: ...DA SERIES EN HADA Series NETWORKABLE AMPLIFIERS Digital Amplifiers USER MANUAL PRECAUTIONS PACKAGE CONTENTS DESCRIPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRAN...

Страница 2: ...NECT 10 6 1 Location Assembly and Ventilation 10 6 2 Mains Connection 11 6 3 Analogue Input Connections 12 6 4 Amplified Output Connections 13 6 4 1 Out Configurations 13 6 5 Remote Volume 14 6 5 1 Co...

Страница 3: ...GE CONTENTS DESCRIPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 1 HADA 4B150 35 8 2 2 HADA 4B250 36 8 2 3 HADA 4B400 37 8 2 4 HADA 4B500 38 8...

Страница 4: ...intenance servicing for which instructions may be found in the literature accompanying the appliance WARNING If applicable The terminals marked with symbol may be of sufficient magnitude to pose a ris...

Страница 5: ...g lightening sorts or when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing is required when the device has been damaged in any way such as power supply cord or...

Страница 6: ...Services All ECLER products are covered by warranty please refer to www ecler com or the warranty card included with this product for the period of validity and conditions Ecler is truly committed wit...

Страница 7: ...ctionality includes a matrix mixer for selecting which input channels to allocate to the outputs Processing includes 10 band EQ HP and LP filters limiters multi band compressors delay up to 2 sec and...

Страница 8: ...e one taking control of the bridged channel pair and 2 or 4 will be then inactive For further information see HADA DSP Manager chapter The front panel knobs can be disabled by holding down the ON butt...

Страница 9: ...th the ON LED 8 Thermal indicator LED lights up in red colour when temperature limiter is activated 9 Ext Mute LED lights up in white colour when the external mute is active 10 Data indicator LED ligh...

Страница 10: ...previously set the volume gain controls to minimum level Always use shielded cables to make connections between devices In an amplifier avoid placing the speaker output cables close to other signal c...

Страница 11: ...any country in the world On the rear panel there is an on off switch for the unit In the front panel there is the button ON with its LED indicator that illuminates when the unit is in operation To en...

Страница 12: ...inputs The selection of hardware inputs and their routing and mixing towards either amplifier channel is performed from its embedded web application For further information please refer to HADA DSP Ma...

Страница 13: ...hannels Please connect the loudspeakers as reported on the silkscreens when HiZ mode or Bridge mode is required Make sure to match the impedance of the total load connected to the loudspeakers when wo...

Страница 14: ...combination with front potentiometers the potentiometer set at the lower value between the two is the one that defines the maximum output level 6 5 1 Connecting the REMOTE VOL Control Ports The REMOT...

Страница 15: ...stron Extron AMX Vity Medialon etc registered trademarks by their manufacturers using the third party TCP IP control embedded in HADA devices Refer to the Telnet Control chapter for more information 6...

Страница 16: ...te the device is operational To enter in standby mode press and hold the ON button until all LEDs on the front panel blink once The prot LED red will illuminate together with the ON LED white to indic...

Страница 17: ...server as in standard networks the HADA network interface will take a random address in the 169 254 x y class If your PC s network card is also configured in DHCP mode through the automatic discovery...

Страница 18: ...idge Mono mode is set connect the loudspeakers line at 100V or 70V as indicated below The Positive pin of the output in bridge mode is the left one When channel 1 and 2 are set as bridge the input con...

Страница 19: ...ADA DSP Manager and update the firmware again with the correct firmware of each HADA model When the unit is in this special state all the front LEDs of the unit Prot Thermal Ext Mute Data and ON will...

Страница 20: ...PUT POWER all channels driven 1 THD Max output power 8 125W Max output power 4 Max output power 8 bridge mode 125W 250W Max output power 100V 250W Bridge Mode Max output power 70V 250W Bridge Mode SIG...

Страница 21: ...x4 GPIs 0 3 3V 5 pin Euroblock connector rear panel External MUTE Yes dry contact 2 pins Euroblock connector rear panel Euroblock pitch 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amp...

Страница 22: ...DSP Manager Others Preset management 4x4 Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity...

Страница 23: ...Max output power 100V 500W Bridge Mode Max output power 70V 500W Bridge Mode SIGNAL Voltage gain 30 to 37 dBV 32 2 to 39 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nominal...

Страница 24: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Страница 25: ...4 Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 85 RH non condensing Storage temperat...

Страница 26: ...Max output power 100V 800W Bridge mode Max output power 70V 800W Bridge Mode SIGNAL Voltage gain 31 to 38 dBV 33 2 to 40 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nominal...

Страница 27: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Страница 28: ...4 Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 80 RH non condensing Storage temperat...

Страница 29: ...Max output power 100V 1000W Bridge mode Max output power 70V 1000W Bridge mode SIGNAL Voltage gain 31 to 37 dBV 33 2 to 39 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nomina...

Страница 30: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Страница 31: ...Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 80 RH non condensing Storage temperatu...

Страница 32: ...output power 100V 1500W Bridge Mode Max output power 70V 1500W Bridge Mode SIGNAL Voltage gain 31 to 38 dBV 33 2 to 40 2 dBu Input sensitivity 12 to 12 dBV 9 8 to 14 2 dBu 0 25 to 3 98 Vrms Nominal po...

Страница 33: ...h 3 5 mm LOCAL CONTROL Attenuators Front panel knobs Defaults Amplified OUTs attenuators Output mode settings Lo Z Hi Z 70V 100V 4 8 Output mode selection per couple of channels Software RUN SLEEP mod...

Страница 34: ...Matrix Mixer Settings via HADA DSP Manager PHYSICAL Operating temperature Min 0 C 32 F Max 40 C 104 F performance may be reduced above 40 C Operating humidity 5 80 RH non condensing Storage temperatu...

Страница 35: ...ES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 Mechanical Diagrams 8 2 1 HADA 4B150 482 6 286 5 30 4 281 5 88 www ecler com 61 1116 0100 Ecler HADA 4B150...

Страница 36: ...IPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 2 HADA 4B250 88 286 5 4 30 281 5 482 6 www ecler com 61 1117 0100 Ecler HADA 4B250 Mechanical...

Страница 37: ...IPTION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 3 HADA 4B400 88 286 5 4 30 281 5 482 6 www ecler com 61 1118 0100 Ecler HADA 4B400 Mechanical...

Страница 38: ...TION FEATURES PANEL FUNCTONS INSTALL CONNECT START UP OPERATION TECHNICAL DATA WARRANTY ENVIRONMENT 8 2 4 HADA 4B500 ww w ecler com 61 1119 010 0 Ecler HADA 4B500 Mechanical Diagram All the mea surmen...

Страница 39: ...RONMENT 8 2 5 HADA 4B750 ww w ecler com 61 1120 0100 Ecler HADA 4B750 Mechanical Diagram All the measurments are in mm 482 6 286 5 30 4 2 81 5 88 A t t ent i o n F or BR I D G E M ode chang e D SP Set...

Страница 40: ...to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries c...

Отзывы: