background image

 

eCA120HZDN: 

The powered 

output (

OUTPUT

) uses 

a Euroblock connector with a common terminal 

(0V),  a  terminal  for  a  70V  line  and  another  terminal  for  a  100V  line.  Always  use  the 

common terminal and, depending on the type of speaker in the system, one of the two 

others, 70 / 100V, to feed the loudspeaker line. 

The connection cable that connects the eCA120HZDN connectors and the speakers 

should be good quality, with a suitable cross section and as short as possible. 

The OUTPUT provides a powered version of the mono-converted input signal.  

Remember that the total power used by the speakers connected to the eCA120HZDN 
output should not exceed the maximum power it can provide. 

In addition, eCA120DN and eCA120HZDN 

feature an aux audio output (

AUX OUTPUT

with Euroblock connector. This stereo audio signal is identical to the powered signal, 

but with LINE level. Perfect to connect an additional audio system like a self-powered 

sub-woofer for bass reinforcement. 

Remote control port 

The RJ

-45 

(

REMOTE

)

 connector allows to connect a WPmVOL-type wall control panel 

(or  another  model  of  the  WPm  series)  to  adjust  the  overall  output  volume.  The 

connection is made with a standard CAT5/CAT6 cable between the WPm wall panel and 

the REMOTE connector of the eCA120DN / eCA120HZDN. 

 
OPERATION

 

AND

 

USAGE

 

Start up 
 

Start up the eCA120DN / eCA120HZDN by connecting the equipment to an external 

power source to which the 

DC  IN 

24V  connector of the amplifier  has already been 

connected. The LED indicator 

ON/STBY

 immediately lights up on the front panel. We 

recommend you turn on all the devices in the following order: sound sources, mixer, 

equalisers, active filters and processors and, finally power amplifiers. Powering off 
should be done by following the exact reverse sequence. Following this order, the 

introduced noise due to turning on or switching off the devices will not affect those 
further on in the chain and will be inaudible. 

Содержание eCA120HZDN

Страница 1: ...eCA120DN eCA120HZDN COMPACT AMPLIFIERS Dante interface amplifier USER MANUAL...

Страница 2: ...note 3 Precautions 3 Introduction 4 Key features 4 Positioning and fitting 5 Connecting 5 Operation and usage 8 Cleaning 10 Front panel 11 Rear panel 11 Technical characteristics 12 Block diagram 12...

Страница 3: ...mend that maintenance be carried out by our authorized Technical Services PRECAUTIONS Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatu...

Страница 4: ...1 x auxiliary audio output Euroblock connector for connecting to a sub woofer unit e g 1 x unbalanced stereo input LINE INPUT with dual RCA connector and 3 in Euroblock connector 2 x Dante audio inpu...

Страница 5: ...es not require forced cooling however it must be prevented from installing the unit in dusty environments with extreme temperature and or humidity conditions The unit must be away from noise and inter...

Страница 6: ...ck connector LINE IN This input is designed to support 6dBV to 0dBV signals given that the rotary volume control of the front panel provides an extra 6dB of gain at its maximum position This audio inp...

Страница 7: ...erfect to connect an additional audio system like a self powered sub woofer for bass reinforcement Remote control port The RJ 45 REMOTE connector allows to connect a WPmVOL type wall control panel or...

Страница 8: ...ignals will have priority over the other that is to say when signal presence is detected in the priority input signal level exceeds the threshold the input signal selected with INPUT SELECT switch wil...

Страница 9: ...2 following assumptions may occur a There is NO audio signal in the inputs Result the amplifier immediately goes into AUTO STANDBY mode b There is an audio signal in the inputs Result the amplifier st...

Страница 10: ...e FAST SLOW recovery AUTO STBY turns ON OFF the AUTO STANDBY function When the function is on the eCA120DN eCA120HZDN will automatically go into STANDBY or low consumption mode in the absence of audio...

Страница 11: ...tch 2 PRIO MODE priority function switch 3 DANTE INPUT Dante audio adjust trimmer 4 LINE INPUT analogue audio adjust trimmer 5 MASTER VOLUME control 6 SP signal presence indicator light 7 CLIP indicat...

Страница 12: ...e switch FAST SLOW 11 AUTO STBY ON OFF switch 12 LINE INPUT RCA connector 13 LINE INPUT Euroblock connector 14 REMOTE VOLUME RJ 45 connector 15 AUX OUTPUT auxiliary LINE output Euroblock connector 16A...

Страница 13: ...onnector 1 x RJ45 Cable length between devices 100m CAT5 or CAT5e CAT6 Priority and input mode Priority function Threshold 30dB Priority release time with Fade in Fast 4seg Slow 18 seg Miscellaneous R...

Страница 14: ...14 BLOCK DIAGRAM eCA120DN...

Страница 15: ...15 eCA120HZDN...

Страница 16: ...e loudspeakers on a desktop Quick start guide Warranty card All product characteristics are subject to variation due to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make change...

Отзывы: