Ecler DP400 Скачать руководство пользователя страница 20

 

20

CONFIG MENU – PRESET

 

 

 

This option allows you to choose the operating mode (preset) for the 

DP400. See section 6.1 for further information about the available operating 
modes. 
 

 

The stereo operating modes (numbers 1 and 2) include the possibility of 

working in stereo link. With a stereo link, all of the parameters modified in one 
channel (input or output) are automatically copied and updated in another 
associated channel. 
 

 

The following parameters are not copied, even if the stereo link operating 

mode is active: 
 



Output selected to go with a particular input 



MUTE status of an input or output 



Phase invert status of an output 

 

 

E.g.: When the 2x3 WAY CROSSOVER is activated with the stereo link option, the inputs and 

output channels will automatically be grouped as follows: 
 
Inputs: IN CH1&IN CH2 
 
Outputs (channels): 
 



Low: Out1&Out4 



Mid: Out2&Out5 



High: Out3&Out6 

 

CONFIG MENU – COPY DATA 
 

 

With the copy data option, you can copy all the parameters from one 

input to another or from one output or channel to another. 
 

 

This option is especially useful in mono operating modes where each of 

the outputs should have the same parameters as all the others. 
 

CONFIG MENU – LOCK/UNLOCK

 

 

 

Selecting this option calls up a window that allows you to select the lock type 

and the associated password. See section 6.3 for more information about the various 
safety lock types offered by the DP400. 
 

 

After you have chosen the desired safety lock type and entered a password, the 

values that cannot be edited or seen will be shown in yellow in 

DP:lab2

 
WARNING: it is very important to keep your password in a safe location. It cannot be 
recovered if forgotten or lost. 

Содержание DP400

Страница 1: ...USER MANUAL ...

Страница 2: ...2 ...

Страница 3: ...EL 07 5 REAR PANEL 09 6 THE MAIN MENU 10 7 INPUTS 12 8 OUTPUTS 13 9 SOFTWARE 15 10 TECHNICAL CHARACTERISTICS 24 All numbers subject to variation due to production tolerances ECLER S A reserves the right to make changes or improvements in manufacturing or design which may affect specifications ...

Страница 4: ... are no user serviceable parts inside the unit Ground Loops Care should be taken so that the different mechanical and electrical grounds as well as the chassis and ground connections arriving to the device to be independent from each other Ground loops can be easily detected through a low frequency hum noise 50Hz Depending on the level of this noise it can interfere on the music quality Audio conn...

Страница 5: ...l cover of the device should never be removed under any circumstance for that same reason The DP400 operates with alternate current AC between 90 and 264V at 47 to 63Hz This device features an oversized power supply which adapts itself to any mains voltage around the world without the need of manual adjustment Even though the noise produced by powering up is minimum it is always advisable to follo...

Страница 6: ...way o All inputs and outputs muted Selectable Crossover slopes of 6 12 18 24 or 48dB per octave and filter types Butterworth Linkwitz Riley or Bessel Parametric or shelving equalizer for a smooth system frequency response Input and channel gain adjustment range from 40 dB to 12 dB Limiter and compressor Limiter compressor output attack and release times with adjustable threshold Phase invert optio...

Страница 7: ...n output with a trigger threshold of 0dB the 6dB led will light up MUTE Buttons By pressing these buttons one for each output channel the selected channel is muted If the output is muted the associated led next to the button is lit Rotary encoder wheel By turning the encoder wheel clockwise or counter clockwise parameters and values shown on the display can be incremented or decremented The encode...

Страница 8: ... also used to confirm certain actions RECALL Key Press this button whenever you wish to recall a previously saved program from the internal memory of the DP400 To recall a program stored in memory first press RECALL and then select the desired program using the ENCODER Once selected press ENTER LCD Display The blue backlit LCD features two rows of 20 characters The upper left part shows the input ...

Страница 9: ...he unit please ensure that the DP400 is connected to earth and that the electrical installation fulfils the local safety regulations Input Connectors CH1 CH2 and Output Connectors Output 1 6 The DP400 has two inputs CH1 and CH2 on three pin female XLR sockets The pin layout is following Pin 1 is Ground Pin 2 is signal hot and Pin 3 is signal cold The six outputs of the DP400 OUTPUT 1 6 are on thre...

Страница 10: ...00 allows the following operating modes 1 x over 2x2 way 1 extra output 2 2x3 way stereo 3 x over 4 way 2 extra outputs 4 x over 5 way 1 extra output 5 x over 6 way 6 All inputs and outputs muted Once installed and switched on the unit should be configured in order to choose the operating mode preset For this you must Press the ENCODER several times until MAIN MENU PROGRAM appears on the screen Pr...

Страница 11: ... described below Modify the data may be seen but cannot be modified The input and channel MUTE functions remain active Modify and view the data may be not be seen or modified The recall and storage of programs in memory is blocked The input and channel MUTE functions remain active Modify and MUTE this option is similar to Modify except that the input and output MUTE functions are also blocked The ...

Страница 12: ...ing modifications to each of the inputs Input gain can be adjusted from 40 dB to 12 dB Input delay can be adjusted from 0 ms to 682 52 ms The LCD screen will automatically show the corresponding values in metres m and feet ft Input equalization EQ the processor allows the following types of equalization o Parametric Peq o Lo12 Low 12 dB oct o Lo6 Low 6 dB oct o Hi12 High 12 dB oct o Hi6 High 6 dB ...

Страница 13: ...dB phase in phase or out of phase and which input IN A IN B IN A IN B and OFF corresponds with the current output Channel delay can be adjusted from 0 ms to 21 31 ms The LCD screen will automatically show the corresponding values in metres m and feet ft Channel equalization EQ the processor allows the following types of equalization o Parametric Peq o Lo12 Low 12 dB oct o Lo6 Low 6 dB oct o Hi12 H...

Страница 14: ...ge component that can easily damage the loudspeakers To avoid this the limiter compressor should be adjusted to avoid saturation of the amplifier in order to prevent damage to the loudspeakers On the other hand if the amplifier has a larger power output than the loudspeakers can handle or the system must operate during long periods at full power the limiter compressor must be adjusted such that th...

Страница 15: ...P Professional Windows 2000 or Vista operating system With the use of this software application the operating mode the crossover filters and the input and output equalizations can be configured in the same aspects as would be done from the unit itself The communication between the PC and the DP400 unit is done with a USB cable It is important to keep in mind that when using DP lab2 to manage the D...

Страница 16: ...ks you for the application installation directory Once the path has been selected in case the default path is not used press the Next button so that the next screen appears Here the position of the direct access icon for DP lab2 can be chosen Normally the default position is a good choice Pressing the Next button On this screen you have the option to create direct access links Immediately after th...

Страница 17: ... CD If this method is not compatible with your computer connect the USB cable first and when the system will ask for the driver files tell the complete path of the Drivers on the CD ROM To check the proper installation go to Device Manager The mixer should appear under Prolific USB to Serial Comm Port COM Take note of the automatically assigned COM port number ...

Страница 18: ... icon executes the application so that all parameters can be adjusted Following main screen appears Before pressing CONNECT assign the same COM port number that was assigned to the drivers To change it use the CONFIG RS232 menu ...

Страница 19: ... steps you are ready to modify the input and output parameters and operating modes presets recall and store configurations in the DP400 and PC and apply the desired password protected safety lock all from your computer Disconnecting the DP400 from the computer After you have finished using DP lab2 with the DP400 connected to the computer you must deactivate the virtual CONNECT button on the upper ...

Страница 20: ...tput channels will automatically be grouped as follows Inputs IN CH1 IN CH2 Outputs channels Low Out1 Out4 Mid Out2 Out5 High Out3 Out6 CONFIG MENU COPY DATA With the copy data option you can copy all the parameters from one input to another or from one output or channel to another This option is especially useful in mono operating modes where each of the outputs should have the same parameters as...

Страница 21: ...ory where you would like to store the configuration and enter a name for it When you press OK the configuration currently loaded in DP lab2 will be saved to the selected space in the memory of the DP400 Recall from Device This allows you to load a configuration from the selected DP400 memory block to the computer so you can edit and or store it on the PC with DP lab2 Delete from Device This allows...

Страница 22: ... PARAMETRIC EQ Use the virtual knobs and the type pull down menu to choose the type of equalization to apply to the selected input its frequency gain and the bandwidth BW in the case of parametric equalization DP lab2 allows up to 6 equalization points Peq for each input To modify the parameter values for a particular Peq you must first select it from the list on the screen You can use the mouse t...

Страница 23: ...f frequency Channel equalization PARAMETRIC EQ Use the virtual knobs and the type pull down menu to choose the type of equalization to apply to the selected output its frequency gain and the bandwidth BW in the case of parametric equalization DP lab2 allows up to 4 equalization points Peq for each channel To modify the parameter values for a particular Peq shown in white you must first select it f...

Страница 24: ...orth or Bessel DELAYS Input delay step 682 52ms 21µs Output delay step 21 31ms 21µs EQ Input EQ quantity 6 per channel Output EQ quantity 4 per channel EQ type Parametric L Shelf 6dB L Shelf 12dB HShelf 6dB H Shelf 12dB EQ gain 30dB 15dB step 0 1dB EQ bandwidth 0 016 to 4 octaves EQ frequency 19 7Hz 21 9kHz COMPRESSOR Threshold 20 10 dBV Attack time 0 5 50ms Release time 10 1000ms Ratio 1 1 2 to 1...

Отзывы: