background image

 

 

 

AS9216 

Version 2.1.RX 

 Installation and Maintenance 

Manual 

492006-2306-013-A00 

 

 

Содержание AS9216

Страница 1: ...AS9216 Version 2 1 RX Installation and Maintenance Manual 492006 2306 013 A00 ...

Страница 2: ...tain flaws omissions or typesetting errors No warranty is granted nor liability assumed in relation thereto unless specifically undertaken in ECI Telecom s sales contract or order confirmation Information contained in the documentation and in the disk is periodically updated and changes will be incorporated in subsequent editions If you have encountered an error please notify ECI Telecom All speci...

Страница 3: ... The 9216 ACPS or 9216 DCPS Units 2 3 The 9216 FAN 2 3 The Reset to Defaults Switch RST 2 4 The Device MAC Address 2 4 The Front Panel LEDs 2 5 Platform Installation 3 1 Overview 3 1 Package Content 3 1 Unpacking 3 2 Rack Mounting AS9216 3 2 Grounding AS9216 3 3 Connecting to a Power Source 3 5 Connecting to the Console Port 3 7 AS9216 Configuration 4 1 Initial Configuration 4 1 Backing up the Dev...

Страница 4: ...CPS Module 6 1 Hot Swap 9216 FAN 6 2 Specifications 7 1 Using the Command Line Interface CLI 8 1 Overview 8 1 Accessing the CLI 8 2 The CLI Modes 8 3 Committing Configuration Commands 8 4 Using the CLI 8 6 Setup and Maintenance 9 1 CLI over Secure Shell SSH and Telnet 9 1 Managing the Device via SNMP 9 2 Managing the Device via NETCONF 9 3 Software Download 9 10 ...

Страница 5: ... brackets to AS9216 3 2 Figure 3 2 Mounting AS9216 3 3 Figure 3 3 The AS9216 front grounding posts 3 3 Figure 3 4 Compression grounding lug 3 4 Figure 3 5 The AS9216 9216 DCPS 3 7 Figure 6 1 Hot swapping a 9216 DCPS or 9216 ACPS 6 2 Figure 6 2 Hot swapping a 9216 FAN 6 2 Figure 8 1 CLI Modes Hierarchy 8 4 Figure 9 1 SNMP Management over the Network 9 2 ...

Страница 6: ...List of Figures AS9216 Installation and Maintenance Manual iv ECI Telecom Ltd Proprietary 492006 2306 013 A00 ...

Страница 7: ...e 7 4 Management Features 7 2 Table 8 1 CLI Syntax Conventions in the User Guide 8 7 Table 8 2 Common Regular Expressions 8 9 Table 8 3 CLI Help Options 8 10 Table 8 4 CLI Keyboard Sequences 8 15 Table 8 5 CLI Messages 8 16 Table 8 6 General Operational Mode Commands 8 18 Table 8 7 Show Commands 8 21 Table 8 8 General Configuration Mode Commands 8 25 Table 9 1 NETCONF Standard Capabilities 9 4 ...

Страница 8: ...List of Tables AS9216 Installation and Maintenance Manual vi ECI Telecom Ltd Proprietary 492006 2306 013 A00 ...

Страница 9: ...nd maintenance of the equipment described in this guide may only be done by trained and qualified service personnel Document Organization This manual contains the following information Safety Information AS9216 Panel Components Installing AS9216 AS9216 Configuration Establishing Network Connections Hot Swapping Modules Specifications Using the Command Line Interface CLI Setup and Maintenance About...

Страница 10: ...otes See examples below NOTE Text set off in this manner presents clarifying information specific instructions commentary sidelights or interesting points of information CAUTION Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information WARNING Text set off in this manner indicates that failure to follow directions could resul...

Страница 11: ...his manner includes helpful information and handy hints that can make your task easier IMPORTANT Text set off in this manner presents essential information you must pay attention to Related Documentation AS9216 User Manual Obtaining Technical Documentation To obtain technical documentation related to ECI Telecom products please contact ECI Telecom Ltd Documentation Department 30 Hasivim St Petach ...

Страница 12: ... actual installation process ECI Telecom maintains a staff of design engineers and highly trained field service personnel The services of this group are available to customers at any time If you are interested in obtaining design assistance or a network installation plan from ECI Telecom s Customer Support team contact your ECI Telecom sales representative With any support related issues technical...

Страница 13: ...aintenance of the opened device should be done only while the device is disconnected from its source of power and should only be performed by qualified personnel WARNING WIRING FOR NATIONAL POWER PLUG A mains power cable according to National Electrical Code NEC with molded IEC socket is supplied with each device The specific national mains power plug should be wired as follows Brown lead Live pha...

Страница 14: ...ice unsafe to use Intentional interruption is prohibited This equipment has a connection between the earthed conductor of the DC supply circuit and the grounding conductor WARNING LINE VOLTAGE Before connecting the product to the power line make sure the voltage of the power source matches the requirements of the product as marked on the label located near the power connectors WARNING DC POWER SOU...

Страница 15: ...r emission use only fiber optic transceivers which comply with IEC 60825 1 or IEC 60825 2 and FDA 21 CFR 1040 10 and CFR 1040 1 CAUTION This equipment contains Electrostatic Discharge ESD sensitive components Use ESD protection before servicing or installing components of this system CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for c...

Страница 16: ...y and Electromagnetic Compatibility EMC Safety Requirements UL 60950 CSA 22 2 No 950 EN 60950 IEC 60950 Eye Safety EMC Emissions FCC 47 CFR Part 15 Class A ICES 003 Issue 4 Class A Canada EN 300386 devices in communications center INDOOR use Telcordia GR 1089 issue 4 European CE marking EN 55022 Class A CISPR 22 Class A EN55024 1998 A1 ...

Страница 17: ...s for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with the instruction manual it may cause harmful interference to radio commu...

Страница 18: ...roduct may cause radio interference in which case the user may be required to take adequate measures VCCI Japan Class A This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take cor...

Страница 19: ...the Metro edge and enterprise boundaries AS9216 can function either as the aggregation and or distribution layer in a Metro application or as a core device in medium and small Metro access and enterprise networks High powered networks require a combination of speed and robustness to provide the intensive and fluctuating demands of end users AS9216 can provide the network the ability to enable data...

Страница 20: ... fees NOTE The SFP sockets comply with Multi Source Agreement MSA standard however ECI Telecom guarantees the proper functionality of SFP transceivers that were tested and approved by ECI Telecom only To verify the use of a specific SFP transceiver contact ECI Telecom Technical Support 8 Dual Ports 1 2 1 1 2 8 rate support 10 100 1000Base T or 100Base Fx 1000Base X RJ45 ports SFP Sockets 4 10 GbE ...

Страница 21: ...16 ACPS or 9216 DCPS Units This device has two power supply slots both supporting AC and DC power You can install the device with One power supply either a 9216 DCPS or a 9216 ACPS In this case make sure to cover the unused power supply slot with a blank power supply cover Two power supplies of the same type A combination of 9216 ACPS and 9216 DCPS The 9216 FAN The device s 9216 FAN is hot swappab...

Страница 22: ... Proprietary 492006 2306 013 A00 The Reset to Defaults Switch RST This switch is currently not supported The figure below details AS9216 units and ports Figure 2 1 AS9216 units and ports The Device MAC Address The device s MAC address is on the ID label on the bottom of the chassis ...

Страница 23: ...d a failure during BIST 3 MNG software management activity indicator Off no management activity Blinking Green a current management activity 4 ETH link and activity indicator Off link down Green link up Blinking Green current link activity Power supply 5 PS 9216 ACPS 9216 DCPS status indicator 1 2 Green 9216 DCPS or 9216 ACPS providing power to the main board Red 9216 DCPS or 9216 ACPS is not prov...

Страница 24: ...ber port is administratively disabled 10 RJ45 SFP ports link and activity Off link down Green link up Blinking Green current activity 11 RJ45 SFP ports administrativ e status Off port enabled and link is down Amber port is administratively disabled 12 XFP ports link management and activity Off port enabled and link is down Green link up Blinking Green current activity Amber port is administrativel...

Страница 25: ...is equipment only in a Restricted Access Location per UL 60950 1 clause 1 2 7 3 Package Content The AS9216 package includes the following items AS9216 aggregation device 9216 FAN 1 9216 DCPS or 9216 ACPS 1 power cord Two rack mounting brackets with screws Console cable RJ 45 to RS 232 1 blank power supply box TM PSBLNK Documentation CD 3 Platform Installation ...

Страница 26: ...9216 is an ETSI standard device and you can mount it on a 19 inch equipment rack CAUTION Mounting the device in a 23 inch rack requires special mounting brackets For information about the required operating conditions refer to Table 7 3 Operating Conditions Make sure to have the following equipment not provided Four mounting screws A screwdriver depending on the type of screws used To rack mount t...

Страница 27: ...has grounding posts on both the front and rear panels Figure 3 3 The AS9216 front grounding posts Before powering on the device ground the device using one of the grounding posts to earth as described below CAUTION Do not remove the earth connection unless all power supply connections are disconnected WARNING Before connecting power to the platform make sure that the grounding posts are firmly con...

Страница 28: ...h ground screws on the enclosure For the DC input circuit to the system make sure there is a Listed 30 amp circuit minimum 48Vdc double pole on the input to the terminal block The input wiring for connection to the product should be Listed copper wire 0 AWG marked VW 1 and rated minimum 90 degrees C 2 Remove the bolts and spring washers from the grounding posts either on the front panel or the rea...

Страница 29: ...ut hot swapping the power supply unit refer to Hot Swapping a 9216 DCPS or 9216 ACPS Module Connecting a DC Power Source Before connecting the device to a DC power source make sure that The DC supply source is located within the same premises as the device The DC power source is protected with a circuit breaker with a rating of 5 Amp connected to the non grounding conductor The device is connected...

Страница 30: ...C double pole on the input to the terminal block The input wiring for connection to the product should be Listed copper wire 10 AWG marked VW 1 and rated minimum 90 deg C To connect the device to a DC power source WARNING The 9216 DCPS does not have a Power On Off button and is automatically turned on when the cabling is completed and the power to the feed line is turned on Before wiring the DC pl...

Страница 31: ...eaker 4 Verify that the 9216 DCPS PWR LED and the relevant PS LED are green 5 If you have a redundant 9216 DCPS repeat the steps above to connect it In such scenario both modules PS LEDs are turned on Connecting to the Console Port The AS9216 console port is a EIA232 VT 100 compatible port through which you can define the device s basic operational parameters To connect the device to your PC using...

Страница 32: ...Platform Installation AS9216 Installation and Maintenance Manual 3 8 ECI Telecom Ltd Proprietary 492006 2306 013 A00 ...

Страница 33: ...nterface CLI To define the device s initial parameters follow the below steps 1 Connect the device to a PC using the console port and start a terminal application 2 Connect the device to the power supply 3 The device starts up running startup self tests 4 When the device is ready a screen similar to the following example appears on the console port device name admin connected from 127 0 0 1 using ...

Страница 34: ...ferent subnet e f g h y is the destination network a b c d is the default gateway IP address 10 is the distance static route e f g h y a b c d 10 Step 7 Exit the Static Route mode exit Step 8 Save the current configuration commit NOTE Exiting without committing configuration changes generates the message Uncommitted changes found commit them yes no cancel Type Y to commit save these changes Exampl...

Страница 35: ... SSH Backing up the Device Configuration You can backup the device s configuration details on the device s file system To backup the configuration details Description Command Copy the configuration file file_name is the backup file name file cp running configuration file_name Example device name file cp running configuration filename For further details of Setup and Maintenance refer to Setup and ...

Страница 36: ...AS9216 Configuration AS9216 Installation and Maintenance Manual 4 4 ECI Telecom Ltd Proprietary 492006 2306 013 A00 ...

Страница 37: ... PCs and servers as well as to hubs devices or routers You can also connect it to devices using SFP or XFP transceivers Cabling Guidelines The RJ45 ports on the device support automatic MDI MDI X pinout configuration thus allowing the usage of standard straight through twisted pair cables to connect to any other network device PCs servers switches routers or hubs 5 Establishing Network Connections...

Страница 38: ...other switch or networking device then an LC connector is required Each 1000BASE LX LH and 100BASE LX EX single mode fiber port requires 9 125 micron single mode fiber optic cable Each 1000BASE SX and 100BASE FX multimode fiber optic port requires 50 125 or 62 5 125 micron multimode fiber optic cabling 1000BASE SX LX LH and 100BASE FX LX EX use duplex fiber operating at the same wavelength for bot...

Страница 39: ... a grounded metal surface such as an equipment rack WARNING Use an ESD wrist strap with a series 1 meg ohm resistor 2 Remove the SFP transceiver from its protective package 3 Slide the SFP transceiver into the socket until the transceiver clicks into place Some SFP sockets and SFP transceivers are manufactured without a mechanism that enables a smooth insertion retraction This may prevent you from...

Страница 40: ...e clean Dirty cable plugs on fiber cables impair the quality of the light transmitted through the cable and lead to degraded performance of the port To clean the cable plugs wipe them gently with a clean tissue or cotton ball moistened with ethanol 3 To connect the cable to a subscriber connect one end of the cable to the LC connector on one of the device s SFP transceivers and the other end to th...

Страница 41: ...e fiber port requires 9 125 micron single mode fiber optic cable Each 10GBASE SR multimode fiber optic port requires 50 125 or 62 5 125 micron multimode fiber optic cabling 1000BASE SR LR ER use duplex fiber operating at the same wavelength for both transmit and receive signals SR 850 nm LR 1310 nm ER 1550 nm The 10G fiber optic ports operate at 10 Gbps full duplex NOTE When selecting an XFP fiber...

Страница 42: ...ubber cover 3 Slide the transceiver into the socket until it clicks into place NOTE When the port is not connected to a cable cover the port with the rubber cover to protect its optics 4 Verify that the cable plugs are clean Dirty cable plugs on fiber cables impair the quality of the light transmitted through the cable and lead to degraded performance on the port To clean the cable plugs wipe them...

Страница 43: ...thout interrupting the AS9216 operation To replace a 9216 DCPS or 9216 ACPS WARNING Before removing the 9216 DCPS or 9216 ACPS verify that the power to it is turned off as detailed below 1 Disconnect the power from the 9216 DCPS or 9216 ACPS AC units turn off the unit s power button DC units turn off the power to the feed lines at the supply circuit breaker or disconnect it from the power bus 2 Di...

Страница 44: ... all the way in and fasten the panel screws Figure 6 1 Hot swapping a 9216 DCPS or 9216 ACPS Hot Swap 9216 FAN AS9216 includes one hot swappable 9216 FAN To replace a 9216 FAN 1 Release the 9216 FAN s 2 panel screws 2 Draw the module out of its slot 3 Insert the replacement module in the slot push it carefully all the way in and fasten the panel screws 4 Verify that the 9216 FAN LED is green Figur...

Страница 45: ...440 mm 19 Height 89 mm 2RU Depth 305 mm 12 Weight Chassis without 1 9216 DCPS or 9216 ACPS 7 7 kg 16 97 lbs Single Power Supply 0 6 kg 1 3 lbs Table 7 2 Power Source AC Power Source Voltage 90 132 180 240 Vac 4 2A Frequency 50 60Hz Typical Power consumption 150 W DC Power Source Voltage 36 to 75 VDC 6A Typical Power consumption 130 W 7 Specifications ...

Страница 46: ...ondensing Operating Altitude 6 600 ft 2 012 m Storage Temperature 25º C to 70º C 13º F to 158 F Storage Humidity 95 maximum relative humidity non condensing Storage Altitude 15 000 ft 4 500 m maximum Table 7 4 Management Features Inband Integrated SNMP agent Telnet SSH MIBs Supported MIB II Bridge MIB Private MIB RMON MIB Groups 1 2 3 9 Traps Alarms SNMP traps to NMS Console Port For initial confi...

Страница 47: ... an ASCII terminal Using the CLI commands users can configure the device parameters and maintain them receiving text output on the terminal monitor These system parameters are stored in a non volatile memory and users have to set them up only once The device CLI is password protected 8 Using the Command Line Interface CLI ...

Страница 48: ...twork using Telnet or SSH Once the console port is displayed type your username and password to access the CLI For more information regarding default usernames and passwords refer to the Device Authentication chapter Example login as admin admin 10 3 27 6 s password admin admin connected from 10 3 71 20 using ssh on AS9216 AS9216 The default device name displayed at the prompt is AS9216 Throughout...

Страница 49: ...itial mode that the CLI enters after a successfull login to the CLI device name The Operational mode is primarily used for viewing the system status controlling the CLI environment monitoring and troubleshooting network connectivity initiating the Configuration mode Configuration Mode The Configuration mode is the mode in which users can change the device configuration To enter this mode from Oper...

Страница 50: ...uration mode are not applied to the device s active configuration the running configuration file until after you commit them These commands are applied to a copy of the active configuration called a candidate configuration prior to being committed Use the commit command to save the unapplied configuration changes to the running configuration file The system verifies that no additional changes have...

Страница 51: ...e configuration changes and exit the configuration session type no to exit the configuration session without committing the configuration changes type cancel to remain in the current configuration session without exiting or committing the configuration changes When committing commands the CLI validates the configuration changes and prompts for missing configuration Example device name config route...

Страница 52: ...CLI commands are not case sensitive The general CLI syntax is represented by the following format device name config keyword s argument s keyword s argument s In this format device name config represents the prompt displayed by the device This prompt includes the user defined device name the current CLI mode the command keywords and arguments typed by the user Example In the command below device n...

Страница 53: ...cal argument priority Italic capital letters A string argument NAME bold letters A command keyword copy A B C D An IP address 10 4 0 4 UU SS PP A physical port number in a unit slot port format 1 1 6 HH HH HH HH HH HH A MAC address in a hexadecimal format 00 a0 12 07 0f 78 An optional argument or keyword FILENAME A mandatory argument or keyword enable disable An or between two arguments or keyword...

Страница 54: ...e includes more than one command matching the characters typed the system prompts for further input Example device name co syntax error Possible alternatives starting with co commit Confirm a pending commit complete on space Enable disable completion on space config Manipulate software configuration information Dynamic Completion of Commands In addition to the Minimum Abbreviation functionality th...

Страница 55: ...ular Expressions Key Function Matches any character Matches the beginning of a string Matches the end of a string abc Character class that matches any of the characters abc To specify a character range type a pair of characters separated by a abc Negated character class that matches any character except abc r1 r2 Matches either r1 or r2 r1r2 Matches r1 and then r2 r Matches one or more r r Matches...

Страница 56: ...command s possible completions type the partial command followed immediately by Tab or Space If the partially typed command uniquely identifies a command the full command name is displayed Otherwise the CLI displays a list of possible completions Example device name config mac Possible completions mac Configure MAC access lists mac address table command or abbreviated command Leave no space betwee...

Страница 57: ...ns customer sdp vpls vpws commit Commit current set of changes exit Exit from current mode help Provide help information no Negate a command or set its defaults pwd Display current mode path top Exit to top level and optionally run command Output modifiers command or abbreviated command Leave a space between command and Lists the available keywords or arguments that can follow the specified comman...

Страница 58: ...ents into the CLI Example device name show running config system snmp engine id 80 00 02 e2 03 00 a0 12 64 08 60 no shutdown authentication failure trap view inet 1 3 6 1 included group gr1 noAuthNoPriv read inet write inet notify inet user public gr1 v1 target address ta1 address 192 168 1 100 dst port 162 message model v1 security name public security model noAuthNoPriv timeout 15 retry count 3 ...

Страница 59: ... more enables the output pagination nomore disables the output pagination save saves the command output to a file You are prompted for a file name regular expression see Table 8 2 Example 1 The below example displays only lines that contain 9 device name show port include 9 9 1 1 7 enable down unknown disable disable 0001 11 1 1 9 enable down unknown disable disable 0001 19 1 2 1 enable down unkno...

Страница 60: ...rt 1 1 1 are disabled until the no shutdown command is committed device name config port 1 1 1 device name config port 1 1 1 no shutdown device name config port 1 1 1 commit Using the Command History The CLI maintains a history of commands entered in any CLI mode You can scroll back through the history of commands by pressing the up arrow key You can modify and execute any command displayed in the...

Страница 61: ...trl d Moves one mode back Ctrl k Deletes all characters to the end of the command line Ctrl u or Ctrl x Deletes the command line Ctrl w Esc Backspace or Alt Backspace Deletes the last word Esc d or Alt d Deletes the word after the cursor Ctrl y Inserts the most recently deleted text at the cursor Ctrl p or Up Arrow Moves up to the previous line in the history buffer Ctrl n or Down Arrow Moves down...

Страница 62: ... complete on space Enable disable completion on space config Manipulate software configuration information defaults display Show default values when showing the configuration Syntax error incomplete path Displayed when the user types a valid command but fails to type the command s required arguments device name config port syntax error incomplete path syntax error Possible alternatives starting wi...

Страница 63: ...tory mac address table commit abort confirm persist id complete on space false true config terminal shared exclusive defaults display false true exit help COMMAND no history size id ignore leading space false true logout session session number user USER NAME output file TERMINAL FILE NAME paginate false true quit send USER NAME all MESSAGE show terminal generic xterm vt100 ansi linux who write ter...

Страница 64: ... interface 100 1 1 1 Value for area id IP address 0 0 0 0 Example 2 autowizard false device name autowizard false device name config terminal Entering configuration mode terminal device name config router ospf interface 100 1 1 1 device name config interface 100 1 1 1 clear history Clears all history records commit abort confirm Ends the current configuration abort aborts the commit action confirm...

Страница 65: ...e leading space Ignores any leading white space logout session session number user USER NAME Terminates the specified session session number the session number in the valid range of 1 101 USER NAME the specific user s session output file FILE NAME Writes the CLI output to a terminal or file FILE NAME a string of up to 256 characters paginate false true Defines the CLI output pagination false disab...

Страница 66: ...erminal Displays the running configuration that differs from the factory default values show running config Show Commands root show show routes show bfd session show bist show ethernet show port show snmp show snmp server show snmp system show syslog show active boot parameters show cli show clock show history show interface show mac address table show mpls show oam show qos show router show runni...

Страница 67: ...s chapter show bfd session For details refer to Routing Information and Protocols chapter show bist For details refer to Troubleshooting chapter show ethernet For details refer to Physical Ports and Logical Interfaces chapter show port Displays port configuration show snmp For details refer to SNMP chapter show snmp server For details refer to SNMP chapter Show snmp system For details refer to SNM...

Страница 68: ...ds of the current session show interface Displays IP interface configuration show mac address table For details refer to Administrating the Device chapter show mpls For details refer to MPLS and H VPLS chapter show oam For details refer to OAM chapter show qos For details refer to HQoS chapter show router For details refer to Routing Information and Protocols chapter show running config Displays t...

Страница 69: ... Power Supply Test Power Supply Fans Test Ram Resources Test show system manufacturing details Displays the device Serial number Assembly No Part number Common Language Equipment Identification CLEI HW revision Date Base MAC address show technical support For details see Troubleshooting chapter show version Displays the device software version show vlan For details refer to VLANS chapter show vpls...

Страница 70: ...ION label COMMIT LABEL DESCRIPTION commit check comment COMMIT COMMENT DESCRIPTION label COMMIT LABEL DESCRIPTION label COMMIT LABEL DESCRIPTION comment COMMIT COMMENT DESCRIPTION copy COMMAND do COMMAND end no confirm exit configuration mode level no confirm help COMMAND load merge FILE NAME override FILE NAME pwd resolved revert no confirm rollback configuration number show configuration COMMAND...

Страница 71: ...ment associates a comment with the commit label associates a label with the commit timeout COMMIT COMMENT DESCRIPTION COMMIT LABEL DESCRIPTION commit check comment COMMIT COMMENT DESCRIPTION label COMMIT LABEL DESCRIPTION label COMMIT LABEL DESCRIPTION comment COMMIT COMMENT DESCRIPTION do COMMAND Executes an operational mode command in the Configuration mode end no confirm Exits the Configuration...

Страница 72: ...itted View conflicts with the command show configuration and execute the command resolved when done or exit configuration mode to abort Conflicting configuration items are indicated with a leading Conflicting users admin Use the resolved command to confirm the resolution for the pending changes revert no confirm Copies the running configuration into candidate configuration no confirm exits the Con...

Страница 73: ...ice remotely via SSH or Telnet SSH To access the device via SSH protocol install one of the below supported SSH clients on your PC SSH Communications Security Corp OpenSSH PuTTY terminal program F Secure SSH SecureCRT Other clients that supports SSH version 2 To connect to the device use the device s IP address in the SSH client 9 Setup and Maintenance ...

Страница 74: ... the device using any SNMP based management application Figure 9 1 SNMP Management over the Network To manage the device via SNMP 1 Enable the SNMP protocol on the device refer to the SNMP chapter of this user guide 2 Verify that the Management Information Bases MIBs provided with the release are installed on the management PC 3 Connect your PC to a device port that is assigned to VLAN 1 the defau...

Страница 75: ...set of RPC request operations that trigger the Netconf Agent server in this case AS9216 to respond with a corresponding set of RPC replies NETCONF provides the following features distinction between configuration and state data multiple configuration datastores such as running and startup support for configuration change transactions configuration testing and validation support selective data retr...

Страница 76: ...nges to the running database If the second request does not arrive within a specified time interval the agent automatically reverts the running configuration to the previous version interleave The agent accepts rpc requests besides close session while notification delivery is active The notification capability must also be present if this capability is advertised notification The agent supports th...

Страница 77: ...wever a non standard set option for the edit config operation called test only was defined for this purpose writable running The agent allows the manager to change the running configuration directly Either this capability or the candidate capability is supported by the agent xpath The agent fully supports the XPath 1 0 specification for filtered retrieval of configuration and other database conten...

Страница 78: ...y capability http eci com ns fib 1 0 capability capability http eci com ns glob_defs 1 0 capability capability http eci com ns global_nodes 1 0 capability capability http eci com ns igmpSnoopingV3 1 0 capability capability http eci com ns ldp_node 1 0 capability capability http eci com ns lmm 1 0 capability capability http eci com ns mac_address_table 1 0 capability capability http eci com ns manu...

Страница 79: ... 0 capability capabilities session id 4 session id hello Accessing the Device via NETCONF To access the device via NETCONF 1 Open an SSH2 connection to the NETCONF sub system ssh s p830 admin 10 4 4 69 netconf 2 Type the device password default password is admin admin 10 4 4 69 s password admin 3 The agent and the manager both send a hello message and and a set of capabilities are displayed xml ve...

Страница 80: ...ospf filter get config rpc here it is xml version 1 0 encoding UTF 8 rpc reply xmlns urn ietf params xml ns netconf base 1 0 message id 100 data ospf xmlns http eci com ns ospf 1 0 routerId 1 2 3 66 rou terId areaData areaData ifData ifData virtIfData virtIfData nbrConfigData nbrConfigData areaAggregateDa ta areaAggregateData redistributeData redistributeDat a ospf data rpc reply Change the OSPF r...

Страница 81: ...age id 100 get config source running source filter xmlns http eci com ns ospf 1 0 ospf filter get config rpc here it is xml version 1 0 encoding UTF 8 rpc reply xmlns urn ietf params xml ns netconf base 1 0 message id 100 data ospf xmlns http eci com ns ospf 1 0 routerId 11 22 33 66 routerId areaData areaData ifData ifData virtIfData virtIfData nbrConfigData nbrConfigData areaAggregat eData areaAg...

Страница 82: ...ommand to verify connectivity to the TFTP FTP server 2 If you do not have a router to route traffic between subnets make sure that the device and the TFTP FTP server are in the same subnet 3 The software image file is in the download directory of the TFTP FTP server 4 You have at least Read permissions for the software image file for your username 5 Remove unnecessary inactive images from the AS92...

Страница 83: ...me device name file ls os image 2 Feb 10 29 13 5M 2 1 1 device name pre01 device name tar bz2 3 Feb 13 27 13 5M 2 1 1 device name pre02 device name tar bz2 Number of files 2 27M Flash Size 38 4M Used Space 28 7M Free Space 9 7M device name file rm os image 2 1 1 device name pre01 device name tar bz2 device name file ls os image 1 Jan 00 05 13 5M 2 1 1 device name pre02 device name tar bz2 Number o...

Страница 84: ... via TFTP Server IP address is the TFTP server IP address software image file name is the software image file name file cp os image tftp Server IP address software image file name via FTP user name password is the FTP server username and password Server IP address is the FTP server IP address software image file name is the software image file name file cp os image ftp user name password Server IP...

Страница 85: ...test for validity wait Image pass validation device name file activate os image 2 1 1 device name pre03 device name tar bz2 File 2 1 1 device name pre03 device name tar bz2 is going to be test for validity wait Image pass validation Activating image 2 1 1 device name pre03 device name tar bz2 device name file ls os image 1 Jan 00 05 13 5M 2 1 1 device name pre02 device name tar bz2 1 Jan 00 28 13 ...

Страница 86: ...Setup and Maintenance AS9216 Installation and Maintenance Manual 9 14 ECI Telecom Ltd Proprietary 492006 2306 013 A00 ...