10
Fine-tune elevation angle
. Using the peaking meter, fine-tune the elevation angle. Using a
1/2” wrench, loosen the top elevation nut on the elevation rod to allow the reflector to be moved
up and down in elevation. Move the bottom elevation nut along the elevation rod to adjust
the reflector’s elevation angle and to acieve maximum signal, using the 118.7°W satellite and
transponder 13. After obtaining maximum signal, tighten the top elevation nut on the elevation
rod, then tighten the elevation bolts labeled with a T to the recommended torque value given in
Table 1 on page 9 (see Figure 9).
Figure 9. Fine tuning the elevation angle
Connect cables to LNBF and/or swtich, if a switch is being used
. Remove the
temporary cable used for peaking the reflector.
For switch installation with DISH Pro 500+ LNBF
. Connect a cable from
Port 2D
(119°W) to
Port 1
of the switch. Connect a cable from
Port 1F
(118.7°W) of the DISH Pro 500+ LNBF to
the switch (see Figure 10). If a DP Single or a DP Dual LNBF(s) is being used (DISH Pro 1000+),
connect a cable(s) from the LNBF to the switch (see Figure 5). See Figure 10 for DISH Pro 500+
recommended connection order to a DP34 or DPP33 switch and for DISH 1000+ recommended
connection order to a DPP44 switch. Refer to the switch’s instlalation instructions for additional
details. Leave a service loop around the elevation and skew bracket. Attach the cables to the
bottom of the LNBF support using the included cable clips.
Figure 10. DISH Pro 500+ to DP34 Switch, DISH Pro 500+ to DPP33 Switch, and
DISH Pro 1000+, DISH Pro Plus 500+, and DISH Pro Plus 1000+ to DPP44 Switch
6.
Top
Elevation
Nut
Elevation
Bolt
Bottom
Elevation
Nut
7.
Содержание DISH 500+
Страница 1: ...DISH 500 and DISH 1000 Installation Instructions...
Страница 4: ...2 Quick Installation Instructions Figure 1 DISH 500 and DISH 1000 Antenna System Overview...
Страница 28: ......