background image

Echoflex Installation Guide

ElahoTouch

Configuration

This document guides you through the installation of the ElahoTouch
controller. For more detailed information about graphic configuration options
available, reference the integrated help system.

Installation

Note:

The installation must follow local codes and standard practices.

Install the Mounting Collar

ElahoTouch installs to a 3-gang deep back box, to a specialized ETC
surface-mount back box, or to an ElahoTouch Rack-mount kit.

Listed 3-gang deep back box (by others) - in accordance with NEC and
local electrical codes.

ElahoTouch surface-mount back box, sold separately (order part
number 8186A1116-4) or the locking cover surface-mount back box,
sold separately (order part number 7186A2219). If using a
surface-mount back box by others, it must be in accordance with NEC
and local electrical codes. Reference the Locking Cover installation
instructions before proceeding with the installation.

ElahoTouch Rack-mount kit available from Echoflex (order part number
8186A1117). Reference the Rack-mount kit installation instructions
before proceeding with the installation.

Flush-mount
3-Gang Deep
Back Box 

Optional Spacer

ElahoTouch

Page 4 of 12

Echoflex Solutions, Inc.

Содержание ElahoTouch

Страница 1: ...s compatible with all RDM enabled devices ElahoTouch features 64 Presets shared across the Elaho control system 80 Channels of patchable control 4 internal Sequences DMX sACN and Art Net only Prepare...

Страница 2: ...ring normal operation with a maximum of 750 mA draw Power over Ethernet PoE requires Category 5 cable or approved equal with an RJ45 Category 5 compliant connector terminated to T568B scheme ElahoTouc...

Страница 3: ...tation Termination Kit 8186A1207 for information to terminate Category 5 wiring DMX out using Belden 9729 or equivalent DMX is installed in a daisy chain topology and includes one pair of wires data a...

Страница 4: ...k box by others in accordance with NEC and local electrical codes ElahoTouch surface mount back box sold separately order part number 8186A1116 4 or the locking cover surface mount back box sold separ...

Страница 5: ...es to the installation location Reference Electrical and Auxiliary Wiring Specification on page 2 and Control Wiring Specification on page 3 for details Note The installation must follow local codes a...

Страница 6: ...trol wiring is installed in grounded metal conduit a short run of wire from the ground screw on the grounded back box can be used 2 Strip 1 4 6 mm of insulation from the end of the incoming wire and i...

Страница 7: ...802 3af connects to the RJ45 receptacle on the rear panel Note NEC Class 2 product are to be wired in accordance with NEC Article 725 and local jurisdiction requirements All power and control wiring...

Страница 8: ...ly a piece of 1 16 1 6 mm clear heat shrink to each shield wire 6 Twist each shield wire back onto its data pair and then apply a 1 5 4 cm piece of 3 16 0 5 cm heat shrink all the way down each 3 wire...

Страница 9: ...sed conductors from the cable flush to the cable jacket 4 Label the cable with the data type and run designation for example D1 for DMX run 1 5 Twist the White Orange and Orange conductors as close to...

Страница 10: ...magnets engage Gently wiggle the unit to ensure a secure fit 5 Apply power to the unit After boot up press the button located at the top left of the display to access the ElahoTouch online help system...

Страница 11: ...rive into the ElahoTouch USB receptacle located on the underside of the rear panel 4 Access the front of the touchscreen and navigate to Setup Files Advanced Update Firmware A confirmation message wil...

Страница 12: ...m the mounting collar to gain access to the rear panel Reference Release ElahoTouch from the Mounting Collar on page 10 for instructions 2 Disconnect all power and data connections from the rear panel...

Отзывы: