Echoflex Installation Guide
ElahoTouch
11.
Bend back the unused set of wires and secure them to the cable with a
wire tie.
12.
Secure the terminated wire sets together with a wire tie 2” (5 cm)
from the connector.
DMX Cat5 Cable Preparation and Termination
This instruction assumes use of Cat5 (or equivalent) cable for termination to
the three-position Cat5 insulation displacement connector provided in the
termination kit.
1.
Follow normal Cat5 wire installation procedures to remove 2”
(5 cm) from the end of the cable jacket.
2.
Separate the White/Brown, Orange, and White/Orange conductors
from the cable. These conductors are required for DMX out.
C
O
M
W
/B
R
N
D
a
t
a
-
O
R
G
D
a
t
a
+
(
W
/O
R
G
)
3.
Cut the remaining unused conductors from the cable flush to
the cable jacket.
4.
Label the cable with the data type and run designation (for
example D1 for DMX run 1).
5.
Twist the White/Orange and Orange conductors as close to
the three-position IDC as possible and insert the conductors
through the labeled terminals as follows:
•
Common (White/Brown) to terminal 1
•
Data - (Orange) to terminal 2
•
Data + (White/Orange) to terminal 3
6.
Fully depress each terminal, closing it onto the wire.
7.
Use side-cutters to trim the excess wire from the connector.
Install Touchscreen
1.
Align but do not install the touchscreen to the mounting collar. Ensure
the touchscreen is oriented with the label text and molded rear panel
arrow directed up.
24 VDC
ESD ground
EchoConnect
DMX out
Magnet (x6)
Attachment
Point
Installation
Orientation
Ethernet Port-
PoE, sACN,
Art-Net
USB Port
Reset Button
Status
ElahoTouch
Page 9 of 12