Echoflex Installation Guide
Vacancy Sensor
6. Attach the sensor to the mounting plate by aligning the tabs on the
sensor with the slots on the mounting plate, and then twist clockwise
until the two are secured in place.
Soft Ceiling Tile Installation
EchoConnect and
Ground wire pigtails
optional
Ceiling tile
adapte
r
Terminate
wires here
Ceiling tile
1. Pull the Belden 8471 (or equivalent) and 2.5 mm
2
(14 AWG) ) ground
wire to the mounting location and strip each wire to the appropriate
length. The strip length is dependent on the wire nut or other
termination connector used (wire nuts are not provided).
2. If you are installing the sensor in series with other sensors or
stations (continuing the data run), use the provided EchoConnect and
ESD ground wire pigtails. Termination connectors are not provided. If
you are not continuing the data run, direct termination to the
sensor controller is recommended, skip this step and proceed to
step 3.
a. Strip each wire to the appropriate length, depending on the wire
nut or other termination used (wire nuts are not provided).
b. Twist the incoming data - EchoConnect wire (typically black) and
the data - wire (black) from the EchoConnect pigtail as well as any
continuing data - EchoConnect wire together and secure with a
wire nut.
c. Repeat the above step for the data + EchoConnect wire (typically
white) and for the ESD ground wire (typically green/yellow), using
a new wire nut for each termination type.
Vacancy Sensor
Page 5 of 12