background image

7

S

HRED

 'N' V

AC

®

O

PERATOR

'

S

 M

ANUAL

Proper Clothing -

Wear snug fitting, durable protective clothing;

• Pants should have long legs, shirts with long sleeves.
• DO NOT WEAR SHORTS,
• DO NOT WEAR TIES, SCARVES, JEWELRY.

Wear sturdy protective safety shoes or boots with non-skid soles;

• DO NOT WEAR OPEN TOED SHOES,
• DO NOT OPERATE UNIT BAREFOOTED.

Hot Humid Weather -

Heavy protective clothing can increase operator fatigue which may lead
to heat stroke. Schedule heavy work for early morning or late afternoon
hours when temperatures are cooler.

SAFE

 

OPERATION

Determine Operation Area

- Provide all operators of this equipment with the Operator's Manual,

and instructions for safe operation.

- Review area to be cleared. Look for potential hazards such as stones

or metal objects.

- Spectators and fellow workers must be warned, and children and

animals prevented from coming nearer than 15M (50 ft.) while the
blower/Shred 'N' Vac

®

 is in use.

- Do not operate this product indoors or in inadequately ventilated

areas.

- Take wind conditions into account: avoid open doors and windows.
- Start unit on ground with throttle at idle.  Check that vacuum tube or

blower pipe is not blocked by the ground or by any objects.

- Do not point blower or vacuum tube at people or animals.

Use Proper Clothing & Equipment

- Before starting the unit, equip yourself and any other person working

within the 15M (50 ft.) Safety Zone with the required Protective
Equipment and clothing.

Keep A Firm Grip

- Hold handle with fingers together encircling the handle.

Keep A Solid Stance

- Maintain footing and balance at all times.  Do not stand on slippery,

uneven or unstable surfaces.  Do not work in odd positions or on
ladders. Do not overreach.

- Do not perform Maintenance or Assembly procedures with engine

running.

- Material fed into this machine must be shreddable - metal, rocks,

bottles or other non-shreddable material will damage the machine and
can result in serious personal injury.

15 m (50 ft.)

Содержание Shred 'N' Vac ES-2100

Страница 1: ...erandsafeoperation WARNING DANGER SHRED N VAC MODEL Type 1E ES 2100 Serial Number 001001 Up SHRED N VAC PLUS MODEL Type 1E ES 2400 Serial Number 001001 Up X7501135201 89861009662 10 99 WARNING The eng...

Страница 2: ...feOperation 7 ExtendedOperation ExtremeConditions 8 Description 9 EmissionControl 9 Contents 9 ES 2100 2400MajorComponents 10 Specifications 11 Assembly 12 BlowerApplication 12 Vacuum ShreddingApplica...

Страница 3: ...formation necessary for the protection of the unit NOTE This enclosed message provides tips for use care and maintenance of the unit SAFETY GENERAL DESCRIPTION IMPORTANT See Description and Specificat...

Страница 4: ...ADVERTENCIA SPANISH Read and follow all safety precautions in the operator s manual Operators helpers bystanders can be severely injured by blown objects and must wear specified ANSI Z87 1 eye protec...

Страница 5: ...ringor handling or serious personal injury may result Use an approved fuel container DONOTsmokenearfuel DO NOT allow flames or sparks near fuel Fuel tanks cans may be under pressure Always loosen fuel...

Страница 6: ...t be worn when operating a blower Shred N Vac Physical Condition Your judgment and physical dexterity may not be good if you are tired or sick if you are taking medication if you have taken alcohol or...

Страница 7: ...ft while the blower Shred N Vac is in use Do not operate this product indoors or in inadequately ventilated areas Take wind conditions into account avoid open doors and windows Start unit on ground wi...

Страница 8: ...f you experience discomfort redness and swelling of the fingers followed by whitening and loss of feeling consult your physician before further exposing yourself to cold and vibration Repetitive Stres...

Страница 9: ...95 1999 CALIFORNIA EMISSION REGULATIONS FOR ULGE ENGINES REFER TO OWNER S MANUAL FOR MAINTENANCE SPECIFICATIONS AND ADJUSTMENTS Emission Control Label located on the engine EXAMPLEONLY informationonla...

Страница 10: ...r 9 FUELTANKCAP Coversandsealsfueltank 10 PRIMER BULB Pumping primer bulb before starting engine draws fresh fuel from fuel tank priming the carburetor for starting Pump the bulb 10 times until fuel i...

Страница 11: ...oline engine Displacement 21 2 cc 1 29 cu in 23 6 cc 1 44 cu in Bore 32 2 mm 1 268 in 34 0 mm 1 34 in Stroke 26 0 mm 1 024 in Carburetor Zama Diaphragm model C1U w primer bulb Ignition System Flywheel...

Страница 12: ...to straight pipe 4 Turn fan head nozzle clockwise to lock it into place VACUUM SHREDDINGAPPLICATION Install Vacuum Tube and Bag Assembly IMPORTANT Never operate unit without either housing cover or va...

Страница 13: ...acuum elbow 6 Turn vacuum elbow clockwise to lock it into place 7 Place debris bag opening over end of vacuum elbow and secure with velcro strap E 8 Place shoulder harness over right shoulder 9 Firmly...

Страница 14: ...tions on the oil container Handling Fuel WARNING DANGER FuelisVERYflammable Useextremecarewhenmixing storingor handling or serious personal injury may result Use an approved fuel container DONOTsmoken...

Страница 15: ...e each use OPERATION WARNING DANGER Always wear safety glasses hearing protection and a face filter mask or serious personal injury may result Do not point the blower pipe in the direction of people o...

Страница 16: ...pe D until engine starts and runs Allow unit to warm up at idle for several minutes NOTE If engine does not start with choke in Run position after 4 pulls repeat instructions 6 After engine warm up gr...

Страница 17: ...eople or pets Read the safety section carefully IMPORTANT To avoid engine damage due to over revving do not block vacuum pipe 1 Use only during appropriate hours Check your local ordinances 2 Make sur...

Страница 18: ...he blower pipe in the direction of people or pets Never operate unit without housing cover grill secured by thumb nut otherwise bodily harm may result Read the Safety Section carefully IMPORTANT To av...

Страница 19: ...ee service Regular scheduled maintenance will help your blower SHRED N VAC achieve that goal If you are unsure or are not equipped with the necessary tools you may want to take your unit to an ECHO Se...

Страница 20: ...Inspect Clean I I Muffler Spark Arrestor Inspect Clean I VacuumBag Inspect Replace I Recoil Starter Rope Inspect Clean I Fuel Leaks Inspect Replace I I Spark Plug Clean Replace I R IgnitionSystem Cle...

Страница 21: ...reused be certain it still fits the cavity in the air cleaner cover is installed with the original side out NOTE Carburetor adjustment may be needed after air filter cleaning replacement FUEL FILTER...

Страница 22: ...e careful IMPORTANT To maintain proper engine operating temperatures cooling air must pass freely through the cylinder fin area This flow of air carries combustion heat away from the engine Overheatin...

Страница 23: ...EXHAUST SYSTEM Spark Arrestor Screen Level2 Tools required 13 x 19 mm 1 2 x 3 4 in T Wrench Cross Head Screwdriver Softmetalbrush Parts Required ScreenP N14586240630 GasketLidP N14586642031 1 Remove e...

Страница 24: ...led to unit AdjustmentScrews Idle Speed A Control throttle opening at idle Low LO Speed B Controls amount of fuel at low speed and supplementary fuel for smooth progression from idle to high speed Hi...

Страница 25: ...ion or for long periods during adjustment 1 Start engine run at idle for one minute 2 Complete warm up by running at full throttle for 5 minutes operating choke twice to clear air from carburetor cham...

Страница 26: ...65mm 0 026in Clean or replace Clean or replace Replace plug Engine does not crank Vaccum tube switch on Blower housing not depressed Internal engine problem Correctly install vacuum tube Tighten fan...

Страница 27: ...unit 4 Perform all periodic lubrication and services that are required 5 Tighten all screws and nuts 6 Drain the fuel tank completely and pull the recoil starter handle several times to remove fuel fr...

Страница 28: ...s concerning the application operation or maintenance of this product you may call the ECHO ConsumerProductSupportDepartmentat1 800 673 1558from8 00am to 5 00 pm Central Standard Time Monday through F...

Страница 29: ...missions output meets applicable U S EPA emissions regulations provided that approved maintenance procedures are followed as listed in the Maintenance Section of this manual DESCRIPCI N Page 9 CONTROL...

Отзывы: