PPT-226LA
OPERATION
X7712090701
25
© 06/21 ECHO Incorporated
2.
Choke
Move choke lever (B) to Cold
Start Position (
).
3.
Purge Bulb
Pump purge bulb (C) until fuel is
visible and flows freely in the
clear fuel tank return line. Pump
bulb an additional 4 or 5 times.
4.
Recoil Starter
Lay the unit on a flat area and
keep movable attachment parts
clear of all obstacles. Firmly
grasp throttle handle and throttle trigger lockout with left hand and fully
depress throttle trigger to wide open position. Rapidly pull recoil starter
handle/rope (D) until engine fires (or maximum five [5] pulls).
5.
Choke
After engine fires (or 5 pulls),
move choke lever back to Run
(
) position. Firmly grasp
throttle handle and throttle
trigger lockout with left hand and
fully depress throttle trigger to
wide open position. Pull recoil
starter handle/rope until engine
starts and runs. Release throttle
trigger, and allow unit to warm up
at idle for several minutes.
Note: If engine does not start
with choke in Run
position after 5 pulls,
repeat instructions 2–5.
6.
Throttle Trigger
After engine warm-up, gradually depress throttle trigger to increase
engine RPM to operating speed.
B
C
D