14
INSTALL
BLOWER
PIPES
PB-601
1.
Assemble straight pipe with swivel (C) into flexible pipe (B).
2.
Remove clamp screw (D) on handle (E). Spread clamp and install
onto straight pipe with swivel (C).
3.
Assemble flexible pipe (B) to elbow (G) on blower.
4.
Assemble clamps (A) onto both ends of flexible pipe (B) and
tighten.
5.
Install throttle wire ties in second groove (F) at each end of flexible
pipe. Position throttle linkage so cable passes between the elbow
(G) and frame and runs along the top of the flexible pipe.
B
C
D
E
G
A
B
A
G
F