Component/System

Maintenance

Procedure

Before

Use

Every

Refuel

Daily or

Every 4

Hours

3

Months

or 100
Hours

6 Months

or 300
Hours

Yearly or

600 Hours

Air Filter

Inspect/Replace

I/C

I/C

R*

Fuel Strainer

Inspect/Replace

I

R

Fuel Line

Inspect/Replace

I

I

R*

Carburetor

Inspect/Replace

I/C

R(1)

Choke System

Inspect/Replace

I

Cooling System

Inspect/Clean

I/C

I/C

Muffler Spark Arrestor

Inspect/Clean/Replace

I/C*

R*

Recoil Rope

Inspect/Clean

I

I*

Fuel Leaks

Inspect/Repair

I

I

Spark Plug

Clean/Replace

I/C*

R

Ignition System

Clean/Replace

No Maintenance required for coil and flywheel

Screws/Nuts/Bolts

Inspect/Tighten/Replace

I*

I = INSPECT,  C = CLEAN,   R = REPLACE

M

AINTENANCE

Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help
your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your
unit to an ECHO Service Dealer for maintenance.  To help you decide whether you want to DO-IT-YOURSELF or have the
ECHO Dealer do it, each maintenance task has been graded. If task is not listed, see your ECHO Dealer for repairs.

SKILL

 

LEVEL

Level 1 =

Easy to do. Most required tools come with unit.

Level 2 =

Moderate difficulty. Some specialized tools may be required.

Level 3 =

Experience required. Specialized tools are required. Echo recommends the unit be returned to your Echo
Dealer for servicing.

ECHO offers REPOWER

TM

 Maintenance Kits and Parts to make your maintenance job easier. Just below each task

heading are listed the various part numbers required for that task. See your ECHO dealer for these parts.

MAINTENANCE

 

INTERVALS

IMPORTANT
Time intervals shown are maximum.  Actual use and your experience will determine the frequency of required
maintenance.

*All recommendations to replace are based on finding damaged or wear during inspection.
(1) Replacement will be required for Commercial use after 600 hours. For Consumer use, cleaning every 6 months is required.

Cleaning includes rebuild kits.

Содержание PB-600

Страница 1: ...rulesforsafeoperationandallinstructionscarefully ECHOprovidesthisOperator sManualwhich mustbereadandunderstoodforproperandsafeoperation X750000951 05 00 X7501125401 WARNING The engine exhaust from thi...

Страница 2: ...21 SparkPlug 22 CoolingSystem 22 ExhaustSystem 23 Carburetor Adjustment 23 Troubleshooting 25 Storage 26 ServicingInformation 28 Parts 28 Service 28 ECHO Consumer Product Support 28 Warranty Card 28...

Страница 3: ...WARNING and DANGER calls attention to an act or condition that can lead to serious personal injury to operator and bystanders The circle with the slash symbol means whatever is shown within the circle...

Страница 4: ...AL SYMBOLS Symbol description application Symbol form shape Symbol description application Symbol form shape Hot Surface Carburetor adjustment Idle speed Carburetor adjustment High speed mixture Symbo...

Страница 5: ...it is recommended in this Operator s Manual ATTACHMENTS AND ACCESSORIES FUEL WARNING DANGER FuelisVERYflammable Useextremecarewhenmixing storingor handling or serious personal injury may result Use an...

Страница 6: ...ection that meets ANSI Z87 1 or CE requirements whenever you operate the blower Hand Protection Wear no slip heavy duty work gloves to improve your grip on the blower handle Gloves also reduce the tra...

Страница 7: ...equip yourself and any other person working within the 15M 50 ft Safety Zone with the required Protective Equipment and clothing Keep long hair away from engine and blower intake Retain hair with cap...

Страница 8: ...Injuries It is believed that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in those areas Certain repetitive...

Страница 9: ...TENTS 1 Power Head 1 Blower Pipe Assembly 1 Plastic Bag 1 Operator s Manual 1 Warranty Registration Card 1 ECHO Emissions and Warranty Statement 2 Clampsw screws 1 StickHandleAssembly PB 600Only 1 Bot...

Страница 10: ...10 1 2 3 4 5 6 7 8 13 14 15 16 17 1 2 3 4 7 9 10 11 12 13 14 15 16 17 PB 600 PB 601 12...

Страница 11: ...OPSWITCH PB 600 Combinationstopswitchandvariablespeedthrottle lever When the lever is moved all the way forward the blower is at Wide Open Throttle W O T When the lever is moved rearward to detent the...

Страница 12: ...System Spark Arrestor Muffler Fuel Mixed Gasolineand Two stroke Oil Fuel Oil Ratio 50 1 ECHO High Performance two stroke air cooled engine oil Gasoline 89 Octaneunleaded DO NOT use fuel containingmeth...

Страница 13: ...of flexible pipe B and tighten 4 Loosen wing nut E completely and expand open stick handle clamp F 5 Align notches G in handle clamp with pipe pegs H Stick handle should be angled away from operator 6...

Страница 14: ...to straight pipe with swivel C 3 Assembleflexiblepipe B toelbow G onblower 4 Assemble clamps A onto both ends of flexible pipe B and tighten 5 Install throttle wire ties in second groove F at each end...

Страница 15: ...to 10 Ethyl grain alcohol or 15 MTBE methyl tertiary butyl ether Gasohol containing methyl wood alcohol is NOT approved TwoStrokeOil Atwo strokeengineoilmeeting ISO L EGDStandard ISO CD13738 mustbeus...

Страница 16: ...g Wipe any spilled fuel from the unit Move at least 3M 10 ft from refueling location before starting After use DO NOT store a unit with fuel in its tank Leaks can occur Return unused fuel to an approv...

Страница 17: ...rtable operatingposition PB 600only STARTING COLD ENGINE PB 600 1A Move throttle lever A to START IDLE DETENT position PB 601 1B Move throttle lever A forward to idle position Slide stop switch B forw...

Страница 18: ...le for a few minutes 2 Move throttle lever A to O Stop position PB 601 1 Move throttle lever A forward to idle position and allow engine to idle a few minutes 2 Move stop switch B to Stop position WAR...

Страница 19: ...nningtime 4 Use lower speed to blow dry leaves from a lawn or flower bed 5 Additional speed may be necessary to clean grass and leaves from walks patios and drives 6 Higher speed may be necessary to m...

Страница 20: ...want to take your unit to an ECHO Service Dealer for maintenance To help you decide whether you want to DO IT YOURSELF or have the ECHO Dealer do it each maintenance task has been graded If task is n...

Страница 21: ...y dirty replace 3 If element can be cleaned and reused be certain it still fits the cavity in the air cleaner cover is installed with the original side out FUEL FILTER Level1 Toolsrequired Fuellinehoo...

Страница 22: ...perating temperatures cooling air must pass freely through the cylinder fin area This flow of air carries combustion heat away from the engine Overheating and engine seizure can occur when Air intakes...

Страница 23: ...A gasket B and spark arrestor screen C from muffler Replace screen if plugged with carbon deposits 3 Install spark arrestor screen gaskets and cover 4 Install spark plug and engine cover CARBURETOR A...

Страница 24: ...dE P A emission limits and over rich adjustment but not over lean adjustment which can cause engine failure Do not exceed recommended HI speed engine R P M during operation or for long periods during...

Страница 25: ...ir filte Adjust carburetor See your ECHO deale Spark at end of plug wire No spark at end o plug wire Stop switch off Electrical proble Interlock switc Turn switch on See your ECHO deale See your ECHO...

Страница 26: ...and services that are required 5 Tighten all screws and nuts 6 Drain the fuel tank completely and pull the recoil starter handle several times to remove fuel from the carburetor 7 Remove the spark pl...

Страница 27: ...27 POWER BLOWER OPERATOR S MANUAL NOTES...

Страница 28: ...ConsumerProductSupportDepartmentat1 800 673 1558from8 00am to 5 00 pm Central Standard Time Monday through Friday Before calling please know the model and serial number of your unit to help your Cons...

Отзывы: