Introduction 

The AIO (All-In-One) Test Interface is a USB audio interface compatible with Macintosh 

and Windows computers.  Along with a computer running test software, it provides a 

platform for acoustic testing of cell phones, tablets, computers and their components.  

The AIO combines the functionality of multiple pieces of test equipment into a single, 

integrated device for increased reliability at a reduced cost.  It is ideally suited for a 

high-volume production environment where testing occurs on a continual basis. 

The test computer and AIO communicate using a USB 2.0 Hi-Speed connection.  The 

AIO contains data converters along with input and output amplifiers needed for 

connecting speakers, microphones, and other test equipment.  Audio test tones are 

played out through the AIO and the responses of the unit under test are then recorded 

for analysis. 

The AIO is a modular design consisting of a chassis, a USB Interface Module, and one 

or two audio I/O modules.  The Interface Module is included with every AIO and 

provides the USB connection and power to the unit.  To support different types of test 

stations there are several types of audio I/O modules available for the AIO.  These 

differ in both the type and number of inputs and outputs available on the module.  

Module types may be mixed within a single chassis, allowing for many different AIO 

configurations.  An AIO-S is shown below: 

 

 

 

When a test station needs more inputs and outputs than a single AIO can provide, 

multiple AIOs can be used together as a group.  The audio clocks may be 

synchronized, allowing them to act as if they were a single, integrated unit. 

 

Содержание AIO-2

Страница 1: ...ECHO AIO TEST INTERFACE Product Manual June 2017 2017 Echo Digital Audio...

Страница 2: ...SUPPLY 9 AIO A MODULE 10 MICROPHONE LINE INPUTS 10 CLASS D AMPLIFIED OUTPUTS 11 AIO L MODULE 12 MICROPHONE LINE INPUTS 12 LINE LEVEL HEADPHONE OUTPUTS 13 AIO S MODULE 14 MICROPHONE LINE INPUTS 14 SPK...

Страница 3: ...microphones and other test equipment Audio test tones are played out through the AIO and the responses of the unit under test are then recorded for analysis The AIO is a modular design consisting of...

Страница 4: ...utputs Line HP Outputs Imped Haptic Digital Sample Rates AIO 1 AIO A 4 2 48 96 192 kHz AIO 2 AIO A AIO A 8 4 48 96 192 kHz AIO AT AIO A AIO T 4 2 TDM 10 10 48 kHz AIO L1 AIO L 4 2 48 96 192 kHz AIO L2...

Страница 5: ...tions cont AIO AT AIO Test Interface with 1 AIO A Module and 1 AIO T Module AIO L1 AIO Test Interface with 1 AIO L Module AIO L2 AIO Test Interface with 2 AIO L Modules AIO LT AIO Test Interface with...

Страница 6: ...AIO S and 1 AIO A Modules AIO Dimensions and Weight all models AIO alone 17 5 44 4 cm x 8 75 22 2 cm x 1 75 4 4 cm 7 2 lbs 3 3 kg AIO in box with cables 21 53 cm x 10 25 4 cm x 5 12 7 cm 8 75 lbs 4 k...

Страница 7: ...A surge protector is recommended in areas that are subject to lightning or noise from industrial equipment such as that found on a factory floor 8 Grounding Precautions should be taken so that the gro...

Страница 8: ...O are all powered from the same AC power strip source which includes surge protection To improve reliability and eliminate the possibility of broken switches the AIO doesn t contain a power switch Pow...

Страница 9: ...s have tabs with gold fingers that are inserted into the backplane connectors when installed Signal traces on the backplane connect the Interface Module to the analog I O modules allowing data and com...

Страница 10: ...or passes the commands on to any processors on the modules themselves 4 Downloads software from the host computer onto any modules that require it 5 Stores calibration data for modules that need it in...

Страница 11: ...S interfacing are software controlled Full Scale Input Voltage and Dynamic Range Gain Setting Full Scale Input Voltage Dynamic Range A weighted x1 8 75V 110dB x10 875mV 105dB x100 87 5mV 95dB THDN A w...

Страница 12: ...the speaker should be connected directly across them Both the and outputs are biased at 7 5V Note Connecting a speaker or other low impedance path from one of the outputs to ground will cause the amp...

Страница 13: ...S interfacing are software controlled Full Scale Input Voltage and Dynamic Range Gain Setting Full Scale Input Voltage Dynamic Range A weighted x1 8 75V 110dB x10 875mV 105dB x100 87 5mV 95dB THDN A w...

Страница 14: ...ts are differential with and ground connections For headphones or other low power speakers the ground connection may be ignored Both the and outputs are biased at ground Note Driving loads smaller tha...

Страница 15: ...interfacing are software controlled Full Scale Input Voltage and Dynamic Range Gain Setting Full Scale Input Voltage Dynamic Range A weighted x1 8 75V 110dB x10 875mV 105dB x100 87 5mV 95dB THDN A we...

Страница 16: ...t and Dynamic Range Gain Setting Full Scale SPKR Voltage Full Scale SPKR Current Dynamic Range A weighted x1 8 75V 4 375A 110dB x10 875mV 437 5mA 105dB x100 87 5mV 43 75mA 95dB THDN A weighted 95dB 20...

Страница 17: ...rs The module functions as a TDM master sourcing the clocks and synchronization signals Logic voltage levels are hardware selectable between 1 8V and 3 3V using a jumper on the PCB The TDM interface m...

Страница 18: ...udio APIs Most professional audio and test applications support ASIO which Echo recommends for use with the AIO Multi AIO Synchronization Every AIO has its own internal crystal for generating the audi...