GB
8
9
•
Reception starts automatically every day.
RCC automatic reception times: (OFFSET 0) at 1:00, 2:00, 3:00, 4:00, 5:00. RCC
is received at 1:00, 2:00, 3:00, if no information is received at 3:00, the device
continues to try at 4:00 and 5:00; if the attempt was successful at 4:00, it will
not be repeated, otherwise another will take place at 5:00. If even that fails,
regardless of the reception status, further attempts are repeated the next
day. The duration of receiving RCC information is 7 minutes.
Icon status during reception:
1. When an attempt is made to receive an RCC, the tower portion of the
RCC symbol icon on the LCD flashes at a frequency of 1 Hz.
2. When an RCC signal is received, the tower part of the icon and the arched
antenna symbol of the RCC symbol flash at a frequency of 1 Hz.
3. If the signal is too weak to receive, the tower portion of the RCC symbol
icon flashes at a frequency of 1 Hz and the arched antenna symbol does
not appear.
4. After a successful signal reception, the entire RCC icon lights up and the
reception mode is exited.
•
While receiving a signal, you can cancel RCC reception by holding down
the "DOWN" button for 2 seconds; other buttons do not work.
•
If the signal is not received, another attempt will be made at 2:00 the
next day.
•
If an alarm is activated while receiving an RCC signal, the RCC reception
status is canceled and the unit switches to alarm mode.
•
If DST is available and receiving a signal, the DST symbol will appear on
the LCD display.
•
If the RCC symbols are displayed in full and the time is reset, the
corresponding RCC icon goes out.
Start
•
When switched on and reset, the device displays the entire LCD display
for 3 seconds
after a beep it returns to normal state
checks the
temperature and humidity
automatically goes to RCC reception
leaves it after 7 minutes
end.
•
The default weather icon is partly cloudy.
•
The default temperature unit is Celsius °C, the default time format is 24H,
and the default RF channel is 1.