7
ECCOTEMP MOUNTING CLEARANCES
1
T
op Clearance
: For removal of heating elements and to provide room for plumbing
connections, a minimum of 12 inches is required.
2
Side Clearance
: Allow an overall minimum horizontal space for the heater of 24
inches for removal of protective cover screws and access to electrical wires
entering the heater from the side.
3
Mounting Height
: For safety, ease of installation and service, the suggested height
above the floor is 42 to 48 inches, (minimum 10 inches). Do not install electrical
disconnect or sub-panels below heater as this may interfere with access to the
clean out plates located under the heater.
4
Front Clearance
: In the absence of a door or removal access panel in front of the
heater, allow 32 to 36 inch clearance in front of the heater for protective cover
removal and ease of service.