background image

English

Pressure 

Relief Valve

Discharge Line 

(To Suitable Drain)

Hot 

Water

Supply 

Outlet

Cold Water

Supply Line

Shut-off Valve

Manual Gas 

Appliance 

Shut-Off 

(Suplied)

       WARNING:

Never use an open flame 

to test for gas leaks as 

property damage, personal 

injury, or death could 

result.

The water heater and its gas connections must be leak tested at normal operating 

pressures before it is placed in operation.

Turn on the gas shut-off valve(s) to the water heater.

Use a commercial leak detector or soapy water solution to test for leaks at all

connections and fittings. Bubbles indicate a gas leak that must be corrected.

All connections should also be leak tested after the water heater is placed in 

operation.

Pressure Testing the Gas Supply System

        WARNING: Install a gas pressure regulator, in the gas supply line, which does not exceed the maximum 

supply pressure. DO NOT use an industrial type gas regulator.

The water heater must be isolated from the gas piping system by closing the manual gas shut-off valve during any 

pressure testing of the gas supply piping at pressures equal to or less than 1/2 psi (14’w.c.) .

High Altitude

The Eccotemp 20H and 20HI Gas Tankless Water Heaters have been tested for use at elevations up to 2,000 feet. 

Installation and use of the Eccotemp 20H and 20HI Gas Tankless Water Heaters above 2,000 feet may effect overall 

product efficiency and performance. Installation and use of the Eccotemp 20H and 20HI Gas Tankless Water Heaters 

above 5,000 feet is not recommended.

Leak Testing

A new pressure relief valve, complying with the Standard for relief Valves and Automatic Gas Shut-Off 

Devices for Hot Water Supply Systems, ANSI Z21.22, must be installed at the hot water outlet connection of 

the water heater at the time of installation. Local codes shall govern the installation of relief valves.

For safe operation of the water heater, be sure that:

The pressure rating of the relief valve must not exceed 150 psi, the maximum working pressure of the water

heater as marked on the rating plate.

The BTUH rating of the relief valve must equal or exceed the BTUH input of the water heater as marked on its

rating plate.

No valve of any type should be installed between the relief valve and the water heater.

Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage. Piping

used should be of a type approved for the distribution of hot water.

Hot and cold water lines should be insulated up to the water heater.

The discharge line must be NO SMALLER than the outlet of the valve and must pitch downward to allow

complete drainage (by gravity) of the relief valve and discharge line.

The end of the discharge line should not be threaded or concealed and should be protected from freezing. No

valve of any type, restriction or reducer coupling should be installed in discharge line.

NOTICE: The diagram below illustrates a pressure only relief valve. If local codes require a combination 

temperature and pressure relief valve be installed, an extension piece may be needed.

Relief Valve

NOTICE:

 Local codes govern the installation of relief valves. If local codes 

require that a temperature and pressure relief valve should be installed 

the manufacturer recommends a type 40XL Watts T&P relief valve or an 

equivalent model be used.

NOTICE: 

Manual operation of relief valves should be performed at least 

once a year. Turn off the electrical power and gas shutoff valve. Lift and 

release lever on the relief valve and check the manual operation of the 

relief valve. You should take precaution to avoid contact with the hot 

water coming out of the relief valve and to prevent water damage.

NOTICE:

 If the relief valve on the system discharges periodically, this 

may be due to thermal expansion in a closed water supply system. 

Contact the water supplier or local plumbing inspector on how to correct 

this situation. Do not plug the relief valve.

20HI Installation

Содержание 20H Series

Страница 1: ......

Страница 2: ...ty of this or any other appliances WHAT TO DO IF YOU SMELL GAS Do not try to light any appliances Do not touch any electrical switch do not use any phone in your building Immediately call your gas sup...

Страница 3: ...special ven ng system Refer to the installa on instruc ons for parts list and method of installa on INDOOR USE ONLY Eccotemp Systems LLC 315 A Industrial Road Summerville SC 29483 866 356 1992 AUTOMAT...

Страница 4: ...s required refer to the section on Customer Service Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indication of Important S...

Страница 5: ...lert symbol and either the word DANGER WARNING CAUTION or NOTICE These words mean DANGER An imminently hazardous situation that will result in death or serious injury WARNING A potentially hazardous s...

Страница 6: ...nd liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in...

Страница 7: ...remote control was set at 110 F before it was shipped from the factory The illustration to the bottom left illustrates the Remote Control and how to adjust the water temperature NOTICE When this wate...

Страница 8: ...se units are not certified for any other fuel type LP water heaters should not be installed below grade for example in a basement if such installation is prohibited by federal state and or local laws...

Страница 9: ...able bracing procedures SAFETY PRECAUTIONS Have the installer show you the location of the gas shut off valve and how to shut it off if necessary Turn off the manual shut off valve if the water heater...

Страница 10: ...English Installing the 20 H Outdoor Tankless Water Heater 20H Installation...

Страница 11: ...in a confined space The water heater should be installed close to the most frequently used outlet and its position chosen with safety and service in mind Make sure people particularly children disabl...

Страница 12: ...to breathe but when it passes through a gas flame corrosive elements are released that will shorten the life of any gas burning appliance Propellants from common spray cans or gas leaks from A C and r...

Страница 13: ...the instructions or diagrams provided and take precedent over these instructions Installing the 20H Outdoor Tankless Water Heater Typical Installation Some Items May Not Apply 20H Installation Expansi...

Страница 14: ...e water heater place a drain valve at the lowest point see illustration to the bottom left Gas Supply WARNING Do not attempt to convert this water heater for use with a different type of gas other tha...

Страница 15: ...the hot water coming out of the relief valve and to prevent water damage NOTICE If the relief valve on the system discharges periodically this may be due to thermal expansion in a closed water supply...

Страница 16: ...following minimum clearances and considerations see illustration Twelve 12 inches above grade level and above normal snow levels Four 4 feet below or four 4 feet horizontally from any door window soff...

Страница 17: ...onvenient locations such as the kitchen laundry room or utility room The included remote control can be placed in a convenient location in a bathroom however AVOID areas where water may come into cont...

Страница 18: ...tion site mark and screw two holes with 0 24 with 1 2 depth Insert 2 rubber screws into the holes Place the remote control against the wall align the holes of control with the holes in the wall and fa...

Страница 19: ...e water heater instructions for Hardwiring the Electrical Connections WARNING Shock hazard line voltage is present Before servicing the water heater turn off the electrical power to the water heater a...

Страница 20: ...ng to the illustrations above making sure to insulate all the way to the top Do not cover any drain or pressure valve s Pipe Installation Inlet Pipe and Outlet Pipe Installation Use pressure resistant...

Страница 21: ...Pressure 14 psi Pipe Pressure Loss Faucet and Shower Pressure Loss Safety Margin more than 5 psi Mounting the 20H Outdoor Tankless Water Heater Make sure the location of the water heater allows for e...

Страница 22: ...pressure Air purged from water heater and piping Water connections tight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated...

Страница 23: ...English Installing the 20HI Indoor Tankess Water Heater 20HI Installation...

Страница 24: ...maintained between the vent pipe and combustible material A side wall clearance of 6 inches and a top clearance of 12 inches must be maintained The vent pipe can be up to 32 ft in length with one elbo...

Страница 25: ...e direct ignition system and main burner are no less than 18 inches above the garage floor Hot and cold water lines should be insulated to conserve water and energy The water heater must be located so...

Страница 26: ...n and ventilation If the water heater is installed in a confined space provisions for combustion and ventilation air must be made NOTICE If the duct openings which supply combustion and ventilation ai...

Страница 27: ...Remote Control Gas Supply Line Control Panel Manual Gas Appliance Shut Off Supplied Installing the 20HI Indoor Tankless Water Heater Typical Installation Some Items May Not Apply 20HI Installation Re...

Страница 28: ...essure Min Operating Water Pressure 14 psi Pipe Pressure Loss Faucet and Shower Pressure Loss Safety Margin more than 5 psi To supply hot water to upper floors additional water pressure 0 44 psi ft mu...

Страница 29: ...iment trap should be installed at the bottom of the gas line The inlet gas pressure to the water heater must not exceed 10 5 w c for natural or 14 w c for LP gas For purposes of input adjustment the m...

Страница 30: ...ter be sure that The pressure rating of the relief valve must not exceed 150 psi the maximum working pressure of the water heater as marked on the rating plate The BTUH rating of the relief valve must...

Страница 31: ...heater to the outdoors as outlined in the Venting section of this manual will result in unsafe operation of the water heater causing death serious injury explosion or fire To avoid the risk of fire ex...

Страница 32: ...MUST be installed at the beginning of the horizontal run See page 33 Typical Horizontal Termination w 1 4 per foot UPWARD Slope or page 33 Standard Vertical Vent Termination for examples Number of 90...

Страница 33: ...side of opening 1 ft 300 mm above opening 6 in 15 cm for appliances 10 000 BTUH 3 kW 12 in 30 cm for appliances 10 000 BTUH 3 kW and 100 000 BTUH 30 kW 36 in 91 cm for appliance 100 000 BTUH 30 kW C...

Страница 34: ...Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m M Clearance under veranda porch deck or balcony 12 in 30 For clearances not specified in ANSI Z223 1 NFPA 54 or...

Страница 35: ...rtical Vent Kit 2SVSWTF03 Horizontal Wall Thimble 2SVEEWCF0390 90 Elbow 2SVSWTEF03 Horizontal Wide Wall Thimble 2SVSTEX0390 90 Termination Elbow 2SVEVWC03 Vertical Drain Tee 2SVSTB03 Termination Box 2...

Страница 36: ...Category III vent material only No other vent material is permitted Owner must refer to vent manufacturer s instructions and specifications CAUTION Follow the vent manufacturers installation instructi...

Страница 37: ...tions such as the kitchen laundry room or utility room The included remote control can be placed in a convenient location in a bathroom however AVOID areas where water may come into contact with the c...

Страница 38: ...site mark and screw two holes with 0 24 with 1 2 depth Insert 2 rubber screws into the holes Place the remote control against the wall align the holes of control with the holes in the wall and fasten...

Страница 39: ...ocal codes require hardwiring see instructions for Hardwiring the Electrical Connections WARNING Shock hazard line voltage is present Before servicing the water heater turn off the electrical power to...

Страница 40: ...ulate all the way to the top Do not cover any drain or pressure valve s Pipe Installation Inlet Pipe and Outlet Pipe Installation Use pressure resistant pipe to connect the inlet and outlet water pipe...

Страница 41: ...C VERTICAL INSTALLATION Please refer to local installation professional or venting manufacturer The installation hole in the wall needs to be sealed by fire retardant material or wall thimble making s...

Страница 42: ...ressure Air purged from water heater and piping Water connections tight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated C...

Страница 43: ...reach your gas supplier or fire department DO NOT return to your home until authorized by the gas supplier or fire department C Use only your hand to push in or turn the gas control knob Never use too...

Страница 44: ...you will use is same as the type on the data plate 2 Turn on the main gas valve plug in the power cord be sure the socket is well grounded and press the ON OFF button on the control panel Set temperat...

Страница 45: ...heater is in use or has water flow the display will read the actual temperature To view the set temperature in this condition press UP or DOWN and the set temperature will flash for 3 seconds The hot...

Страница 46: ...t DANGER Before manually operating the relief valve make certain no one will be exposed to the danger of the hot water released by the valve The water may be hot enough to create a scald hazard The wa...

Страница 47: ...freezing temperatures After a long shut down period the water heater s operation and controls should be checked by qualified service personnel Anti Freezing While the Anti Freezers will help to protec...

Страница 48: ...step make sure that COLD water is coming out of all hot water faucets 7 To put the water heater back into operation after draining follow the steps below 8 Reinstall the water filter Close the hot wa...

Страница 49: ...proceeding to the next step make sure that COLD water is coming out of all hot water faucets 7 To put the water heater back into operation after draining follow the steps below 8 Reinstall the water...

Страница 50: ...y or water supply is cut off Check that proper power is being supplied and or water supply is adequate Unit is not ON Turn the unit ON by the button on the remote control The temperature may be set to...

Страница 51: ...ent pipe is blocked clean the pipe If the error code remains shown Close the hot water faucet and turn off the switch on the remote control Take the proper action shown below and attempt operation of...

Страница 52: ...vary from the instructions or diagrams provided and take precedent over these instructions Service Exhaust outlet Exhaust Collector Anti Freezer Thermostat Thermostat Anti freezer Heat Exchanger Prote...

Страница 53: ...r safety DO NOT attempt to disassemble this water heater for any reason Service Exhaust Outlet Exhaust Collector Anti Freezer Thermostat Thermostat Anti Freezer Heat Exchanger Protection Device Burner...

Отзывы: