Flash Pattern Selection:

The flash pattern can be selected by powering the individual flash pattern mode and holding the blue wire to the black wire.

- A quick tap will increment by one pattern.

- 1-3 seconds to go to the previous pattern

- 3-5 seconds to return to the factory default pattern

- 5+ seconds to set to the last flash pattern

Synchronization:

The directional is capable of syncing with other compatible ECCO products by setting the desired flash pattern on each unit individually.  It is also 

strongly recommended that the same rate and style of flash pattern be used on all synced units to produce the most effective warning pattern. 

NOTE: To operate sumultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units must be set to have the 

opposite phase (A + B or B + A).  Then, connect the yellow sync wires together and check that the units are flashing in a synchronized manner as 

expected.  If a pattern on one unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until 

the correct pattern is selected. 

NOTE: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.

CA T13

ECE R65

AMBER, BLUE, RED WHITE

AMBER

CLASS 1S

BLUE

CLASS 1S

RED

CLASS 1S

WHITE

CLASS 1S AMBER, BLUE, RED AMBER, BLUE, RED

1-Default  Single Flash 75FPM sim. Phase1 

yes 

Class 1 

Class 1 

140°

140°

160°

80°

Class B 

N/C

2

Single Flash 75FPM sim. Phase2 

yes 

Class 1 

Class 1 

140°

140°

160°

80°

Class B 

N/C

3

Single Flash 75FPM Alt. 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

4

Single Flash 120FPM sim. Phase1 

yes 

Class 1 

Class 1 

120°

120°

140°

N/C 

N/C 

Class 1

5

Single Flash 120FPM sim. phase2 

yes 

Class 1 

Class 1 

120°

120°

140°

N/C 

N/C 

Class 1

6

Single Flash 120FPM Alt. 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

7

Double Flash 75FPM sim. Phase1 

yes 

Class 1 

Class 1 

140°

140°

160°

80°

Class B 

N/C

8

Double Flash 75FPM sim. phase2 

yes 

Class 1 

Class 1 

140°

140°

160°

80°

Class B 

N/C

9

Double Flash 75FPM Alt. 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

10

Double Flash 120FPM sim. Phase1 

yes 

Class 1 

Class 1 

120°

120°

140°

60°

N/C 

Class 1

11

Double Flash 120FPM sim. phase2 

yes 

Class 1 

Class 1 

120°

120°

140°

60°

N/C 

Class 1

12

Double Flash 120FPM Alt. 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

13

Quad Flash 75FPM sim. Phase1 

yes 

Class 1 

Class 2 

N/C 

N/C 

60°

N/C N/C 

N/C

14

Quad Flash 75FPM sim. Phase2 

yes 

Class 1 

Class 2 

N/C 

N/C 

60°

N/C N/C 

N/C

15

Quad Flash 75FPM Alt. 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

16

Quad Flash 150FPM sim. Phase1 

yes 

Class 1 

Class 2 

N/C 

N/C 

60°

N/C N/C 

N/C

17

Quad Flash 150FPM sim. Phase2 

yes 

Class 1 

Class 2 

N/C 

N/C 

60°

N/C N/C 

N/C

18

Quad Flash 150FPM Alt 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

19

Triple 75FPM sim. Phase1 

yes 

Class 1 

Class 1 

140°

120°

160°

80°

N/C N/C

20

Triple 75FPM sim. Phase2 

yes 

Class 1 

Class 1 

140°

120°

160°

80°

N/C N/C

21

TripleAlter 

75FPM 

Alt. 

yes  N/C 

N/C 

N/C N/C N/C N/C 

N/C 

N/C

22

Quint Flash 150FPM sim. Phase1 

yes 

Class 1 

Class 2 

N/C 

N/C 

60°

N/C N/C 

N/C

23

Quint Flash 150FPM sim. Phase2 

yes 

Class 1 

Class 2 

N/C 

N/C 

60°

N/C N/C 

N/C

24

Quint Flash 150FPM Alt. 

yes 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

9

25

Steady 

Single 

NO  N/C 

N/C 

N/C N/C N/C N/C 

N/C 

N/C

10

26

Steady 

Burn 

NO  N/C 

N/C 

N/C N/C N/C N/C 

N/C 

N/C

11

27

Modulation 

NO  N/C 

N/C 

N/C N/C N/C N/C 

N/C 

N/C

12

28

2 Double Flash,2 Triple Alt. 

NO 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

13

29

4 Single Flash ,2 Quad Flash Alt. 

NO 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C 

N/C

7

8

SINGLE COLOR Flash Pattern Chart/DE UN SOLO COLOR Tabla de patrones de destello/COULEUR UNIQUE Tableau des effets clignotants

1

2

3

4

5

6

PATTERN MODE

DESCRIPTION

SYNC

SAE J595

SAE J845

Содержание ED3777 Series

Страница 1: ...yment area It is the responsibility of the user operator to determine a suitable mounting location ensuring the safety of all passengers inside the vehicle particularly avoiding areas of potential hea...

Страница 2: ...Surface Mount 1 Select a flat mounting surface with the visibility of the flash and ease of wiring access taken into consideration 2 Using the unit or bracket as a template mark the two mounting hole...

Страница 3: ...Routing the ground wire directly back to negative battery terminal is recommended Pack dielectric grease such as Dow Corning 4 around each electric connection exposed to moisture or the ambient enviro...

Страница 4: ...ase2 yes Class 1 Class 1 120 120 140 N C N C Class 1 6 Single Flash 120FPM Alt yes N C N C N C N C N C N C N C N C 7 Double Flash 75FPM sim Phase1 yes Class 1 Class 1 140 140 160 80 Class B N C 8 Doub...

Страница 5: ...ely Color 2 Synchronous Color 4 yes N C N C N C N C N C N C N C 20 20 36 Double 60FPM Color 1 Alternately Color 2 Alternately Color 3 Alternately Color 4 yes N C N C N C N C N C N C N C 21 37 Triple 7...

Страница 6: ...CTURER REGARDING THE PRODUCT AND ITS USE SHALL BE AT MANUFACTURER S DISCRETION THE REPLACEMENT OR REPAIR OF THE PRODUCT OR THE REFUND OF THE PURCHASE PRICE PAID BY BUYER FOR NON CONFORMING PRODUCT IN...

Страница 7: ...salir despedido lo cual puede causar lesiones graves o incluso mortales Consulte el manual del propietario del veh culo para conocer la zona de despliegue de los airbags El usuario u operador son resp...

Страница 8: ...reducci n de la luz se necesita a adir un fusible 2A VERDE Operaci n de luz de suelo se necesita a adir un fusible 2A ROJO BLANCO PRODUCTO 1 Y 3 COLORES 2 Y 4 COLORES ED3777AW MBAR BLANCO ED3777BW AZU...

Страница 9: ...REPRESENTANTE AUTORIZADO DEL FABRICANTE QUE HAGA REFERENCIA EN FORMA EXPRESA A ELLA Exclusi n de otras garant as EL FABRICANTE NO OTORGA NINGUNA OTRA GARANT A EXPRESA O IMPL CITA MEDIANTE LA PRESENTE...

Страница 10: ...ou situ dans la zone de d ploiement d un airbag est susceptible de r duire l efficacit de cet airbag ou de devenir un projectile pouvant causer des blessures graves voire mortelles Reportez vous au ma...

Страница 11: ...ec Pour la configuration pr c dente Entre 3 et 5 sec pour configuration d usine par d faut Plus de 5 sec valeur par d faut au motif no 13 ED3777 et motif no 12 ED3777XX MOUNTING SURFACE Surface de mon...

Страница 12: ...SENTANT AUTORIS DU FABRICANT QUI FAIT EXPRESS MENT R F RENCE LA PR SENTE GARANTIE Exclusion d autres garanties LE FABRICANT N ACCORDE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE LES GARANTIES IMPLICITES...

Отзывы: