Ecco 27 Series Скачать руководство пользователя страница 11

Page 11 of 18

Light Head Group 

Flash Sequence - 

Synchronized

Order

Sequence

1

Off

2

Left/Right

3

Even/Odd

TABLE 8

After the module groups have a sequence selected, a flash pattern rate can be chosen. The default rates are as follows in TABLE 9.

Level Mode Default Patterns by Group - Synchronized
Light Head Group 

Flash Rate

L1

L2

L3

Front

Quad 75 FPM Quad 75 FPM

Cycle

Rear

Quad 75 FPM Quad 75 FPM

Cycle

L1 + L2

L1 + L3

L2 + L3

L1 + L2 + L3

Front

Quad 75 FPM Cycle

Cycle

Cycle

Rear

Quad 75 FPM Cycle

Cycle

Cycle

TABLE 9

To change a light head group flash pattern rate selection:

1. Power-up the Lightbar and apply +power to the appropriate level mode wires (see Table 3) and the BLK/RED Pattern select wire in the

16 conductor cable.

2. Momentarily touch the appropriate light head group wire, shown in Table 10, to +power to cycle through the flash pattern rates shown in

shown in Table 11.

Light Head Group Flash Rate Wires - 

Synchronized

Function Wire Color Light Head Group

BLK

Front

BLU/WHT

Rear

TABLE 10

Light Head Group Flash 

Rates - Synchronized

Order Flash Pattern

1

Double 75 FPM

2

Triple 75 FPM

3

Quad 75 FPM

4

Quint 75 FPM

5

Triple Pop 75 FPM

6

Quad Pop 75 FPM

7

Single 150 FPM

8

Double 150 FPM

9

Triple 150 FPM

10

Quad 150 FPM

11

Quint 150 FPM

12

Triple Pop 150 FPM

13

Quad Pop 150 FPM

14

Single 375 FPM

15

NFPA Qud 77 FPM

16

Cycle Flash

TABLE 11

To restore the Factory Default Emergency Warning Flash Rate to module group in a level mode, hold the appropriate rate selection wire 

and the BLK/RED wire to +power for more than four seconds. The four corner light heads will flash once, and then stay on to indicate that 

the Factory Default Emergency Warning Flash Rate has been restored. 

Содержание 27 Series

Страница 1: ...nate lenses Available in seven standard configurations the 27 Series can be configured with either centrally controlled or independent flashing warning modules offering a choice of either 3 8 12 or 22...

Страница 2: ...The use of this or any other warning device does not ensure all drivers can or will observe or react to an emergency warning signal Never take the right of way for granted It is your responsibility to...

Страница 3: ...feet in location on the lightbar by tightening the four nuts on each foot 3 With the feet positioned remove the adjustable foot cover and mark the location of the mounting hole centers on the roof of...

Страница 4: ...the light bar 2 Place the lightbar over the center of the vehicle and slide the mounting hardware into position near the curved edge when possible as shown in FIGURE 4 3 With the mounting hardware pos...

Страница 5: ...mounting brackets 2 Place the lightbar on the vehicle and slide the mounting brackets into position 3 Secure the brackets to the lightbar with the supplied washers and nuts as shown in FIGURE 5 4 With...

Страница 6: ...lse trip when mounted in hot environments or operated close to their capacity Important This unit is a safety device and it must be connected to its own separate fused power point to assure its contin...

Страница 7: ...rectional and Corner Module Flash Patterns Order Flash Pattern 1 Cycle Flash Default 2 NFPA Quad Flash 80 FPM 3 Steady burn 4 Single Flash 75 FPM 5 Single Flash 150 FPM 6 Single Flash 300 FPM 7 Double...

Страница 8: ...for the con figuration specific functions of each wire Use appropriate high temperature wiring if it passes through the engine compartment Use cable ties and grommets to secure and protect all cables...

Страница 9: ...Flash Rear Inboard Quad 75 FPM Off Cycle Flash Rear Center Quad 75 FPM Off Cycle Flash Rear Corner Quad 75 FPM Off Cycle Flash Rear End Quad 75 FPM Off Cycle Flash L1 L2 L1 L3 L2 L3 L1 L2 L3 Front Ou...

Страница 10: ...ntact ECCO directly Emergency Mode Flash Pattern Selection Synchronized The seven customizable emergency flash pattern modes in Table 3 each have the option to be synchronized This condenses the modul...

Страница 11: ...the appropriate light head group wire shown in Table 10 to power to cycle through the flash pattern rates shown in shown in Table 11 Light Head Group Flash Rate Wires Synchronized Function Wire Color...

Страница 12: ...ad Flash Even Odd 10 Left Right Flash 11 Quad Flash Left Right 12 Travelling Ball Flash TABLE 13 To restore the Factory Default ArrowStik Flash Patterns hold the BLK RED and desired function wire to p...

Страница 13: ...5 L3 YEL Cycle Front Rear 11 L1 L2 BLU ORG Fast In Out Quad Front Rear 1 L1 L3 BLU YEL Cycle Front Rear 11 L2 L3 ORG YEL Cycle Front Rear 11 L1 L2 L3 BLU ORG YEL Cycle Front Rear 11 TABLE 15 To change...

Страница 14: ...e Rear 16 Picket Fence Quad Rear 17 PIcet Fence Six Rear 18 Slow In Out Quad Rear 19 Slow In Out Six Rear 20 Fast In Out Six Rear 21 Variable Rate Picket Fence Single Rear 22 In Out Quad Rear 23 Cycle...

Страница 15: ...1 Uninstall the lens clips 4 per lens as shown in FIGURE 8 using a flat blade screwdriver 2 Insert the screwdriver into the gap along the lens edge and twist the screwdriver to lift the lens 3 When f...

Страница 16: ...d Safety Director for use with centrally controlled modules EZ2127ASCC Controller integrated Safety Director for use with independent flashing modules EZ2127ASIF Driver Board for use with centrally co...

Страница 17: ...USE SOLUTION Does not function Poor power or ground connection In CC Lightbars a green light on the central control board should flash when power is first applied to the bar and during flash pat tern...

Отзывы: