background image

Light Head Group Flash Patterns - 

Unsynchronized

Order Group Flash Rate

1

Quad 75 FPM

2

Single 150 FPM

3

Double 75 FPM

4

Triple Pop 75 FPM

5

Variable Rate - Single

6

NFPA Quad 77 FPM

7

Cycle Flash

8

Off

TABLE 6

To restore the Factory Default Flash Rate to a module group, apply +power to the level you wish to change (see Table 2), then hold the ap

-

propriate rate selection wire and the BLK/RED wire to +power for more than four seconds. The four corner light heads will flash once, and 

then stay on to indicate that the Factory Default setting has been restored. 

For instructions related to the California Title 13 steady burning red warning lamp requirement during level mode operation, please contact 

ECCO directly.

Emergency Mode Flash Pattern Selection – Synchronized

The seven customizable emergency flash pattern modes in Table 3 each have the option to be synchronized. This condenses the module 

groups from TABLE 5 to front and rear. 

To synchronize a set of module groups:

1. Power-up the Lightbar and apply +power to the appropriate level mode wires (see Table 3) and the BLK/RED Pattern select wire in

the 16 conductor cable.

2. Momentarily touch the RED wire to +power set the level mode to synchronized. The four corner modules will turn on each time the

lightbar is toggled between unsynchronized and synchronized.

Once synchronized, the module group in each mode flash sequence defaults to OFF. To change a light head group flash sequence 

selection:

1. Power-up the Lightbar and apply +power to the appropriate level mode wires (see Table 3) and the BLK/RED Pattern select wire in

the 16 conductor cable.

2. Momentarily touch the appropriate light head group wire, shown in Table 7, to +power to cycle through the sequences shown in shown

in Table 7.

Light Head Group Wires - Synchronized

Function Wire 

Color

Light Head Sequence 

Group

GRN/WHT

Front

BLU/BLK

Rear

TABLE 7

Light Head Group 

Flash Sequence - 

Synchronized

Order

Sequence

1

Off

2

Left/Right

3

Even/Odd

TABLE 8

After the module groups have a sequence selected, a flash pattern rate can be chosen. The default rates are as follows in TABLE 9.

Содержание 21 Series

Страница 1: ...ent flashing and CC centrally controlled IF Independent Flashing indicates the lightbars modules have individual electronic circuits that control their operation each module a group or a pair of modul...

Страница 2: ...other obstructions 6 The use of this or any other warning device does not ensure all drivers can or will observe or react to an emergency warning signal Never take the right of way for granted It is y...

Страница 3: ...s on the roof of the vehicle Remove the lightbar and drill the mounting holes as marked Note The center distance between the mounting holes in an adjustable mounting foot is 11 1 or 281 94 mm 4 Attach...

Страница 4: ...possible as shown in FIGURE 4 3 With the mounting hardware positioned mark the location of the mounting hole centers on the roof of the vehicle Remove the lightbar and drill the mounting holes as mar...

Страница 5: ...shers and nuts as shown in FIGURE 5 4 With the mounting brackets positioned mark the locations of the mounting hole centers on the roof of the vehicle Remove the bar and drill the mounting holes as ma...

Страница 6: ...ip when mounted in hot environments or operated close to their capacity Important This unit is a safety device and it must be connected to its own separate fused power point to assure its continued op...

Страница 7: ...h individual module by momentarily short ing together the JP1 pins with a wire or the blade of a screwdriver shown below The light head will reset to the default flash pattern when the JP1 pins are sh...

Страница 8: ...on section below for details Lightbars equipped with a DOT strip assembly are wired in conjunction with the STT tail light function All STT functions are powered independent of the central driver PCA...

Страница 9: ...ont Corner Off Quad 75 FPM Cycle Flash Rear Outboard Quad 75 FPM Off Cycle Flash Rear Inboard Quad 75 FPM Off Cycle Flash Rear Center Quad 75 FPM Off Cycle Flash Rear Corner Quad 75 FPM Off Cycle Flas...

Страница 10: ...onize a set of module groups 1 Power up the Lightbar and apply power to the appropriate level mode wires see Table 3 and the BLK RED Pattern select wire in the 16 conductor cable 2 Momentarily touch t...

Страница 11: ...in Table 11 Light Head Group Flash Rate Wires Synchronized Function Wire Color Light Head Group BLK Front BLU WHT Rear TABLE 10 Light Head Group Flash Rates Synchronized Order Flash Pattern 1 Double...

Страница 12: ...er Flash Pattern 1 Building 2 Building 3 Flash 3 Traveling Ball 3 Flash 4 Build Collapse TABLE 12 Arrowstik Flash Patterns Order Flash Pattern 1 Drivers Side Cut Front corner alley 2 Drivers Side Cut...

Страница 13: ...nitions Function Wire Color Function Description BLU L1 Level 1 Emergency Mode ORG L2 Level 2 Emergency Mode YEL L3 Level 3 Emergency Mode GRN Pattern Select WHT Lightbar Dim Sets LEDs to DIM mode TAB...

Страница 14: ...16 Picket Fence Quad Rear 17 Picket Fence Six Rear 18 Slow In Out Quad Rear 19 Slow In Out Six Rear 20 Fast In Out Six Rear 21 Variable Rate Picket Fence Single Rear 22 In Out Quad Rear 23 Cycle Rear...

Страница 15: ...ips by hooking into the bottom lens slot and pressing the upper portion into the clip pocket LED Module Removal and or Replacement 1 Remove screw s securing the light head assembly to the mounting pla...

Страница 16: ...Kit 22 EZ2122MG Accessories Controller integrated Safety Director for use with centrally controlled modules EZ2127ASCC Controller integrated Safety Director for use with independent flashing modules E...

Страница 17: ...is document PROBLEM POSSIBLE CAUSE SOLUTION Does not function Poor power or ground connection In CC Lightbars a green light on the central control board should flash when power is first applied to the...