![ECCO STOVE 730EC2 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/ecco-stove/730ec2/730ec2_manual_3845327019.webp)
730/03.05.23/V2
P a g e |
19
of 29
Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom
T
| +44 (0) 1527 857 814
E
W
| www.eccostove.com
For all patents
–
See Addendum
J*)
TOP SECTION
This section should be lowered into place and will locate the
sections beneath it with the locating pips. Add all cleaning
plugs into place.
K)
FLUEING
The stove may be connected with a 150mm stove pipe to the flue it will operate on SEE SECTION 19
(FLUE CONNECTIONS) The connecting stove pipe pushes into the flue outlet. Ensure a heat expansion
joint is used.
CAUTION ONLY A RUBBER MALLETT MUST BE USED TO SEAT OR LOCATE PARTS.
THE STOVE MAY NOW BE LIT
23.TECHNICAL
SLOW HEAT RELEASE APPLIANCE BS15250
a)
Outputs: Thermal output 120.7 MJ
Efficiency 86.5%
CO 0.07%
b)
Weight: Complete appliance = 550 kg; The Ecco Stove must be installed onto a structural hearth
capable of bearing this weight.
c)
Air Supply
–
UK 27.5 cm sq.: outside UK to those countries local requirements. Vents to be fitted
to outside and positioned such that they are not liable to block. Additional ventilation
requirement may be needed if the stove is operated simultaneously with other heating
appliances. It is important to ensure adequate supply of combustion and ventilation air.
d)
Extractor fans: No extractor fans are to be fitted in the same room as the Ecco Stove.
e)
Flue draught: Minimum cold flue draught to be .04 inches water gauge, maximum .06 inches
water gauge.
f)
Flue gas mass flow: 9.9g/s
g)
Flue gas temperature: Average 161
˚
C at nominal output.
h)
Flue outlet: 150mm top exit (Dampers may be necessary if the flue draught is in excess of 0.4”
water gauge). This pipe must include a soot door/access plate within 200 mm of the stoves top.
i)
Heat energy stored 109.9 MJ
Fit the four cast iron cleaning plugs into place.