Remove and or clean above the steel gull wing baffle plate in the top of the firebox. 
Ensure the chimney flue and stove pipe are swept early summer time or after stoves shut down 
for the summer.  
Oil the door hinges and door catch mechanism all in readiness for the new heating season. 

a)

 

Adverse flue conditions (downdraught or pressurisation) will result in poor performance; door 
glass blackening and sooting in the flue ways.  Such conditions 

must

 be rectified by improving 

flue performance immediately.  Clean any tar/deposits off the door glass. 

b)

 

Repairs or replacements must be carried out by a competent engineer. 

 

Flueways are accessed by removing the cleaning plugs at a+ b + c + d and brushing vertically with the 
flue brush provided. 
 
Horizontal flue ways should be cleaned via the cleaning plugs at a + b + c + d and debris swept down in 
to the vertical flue ways. 
After cleaning vertically and horizontally the cleaning plugs at c and b should be removed and cleaned 
out with a vacuum cleaner or suction hose. 
 
Lastly remove the gull wing baffle at g and brush off 

 remove the 2 retaining pins in the door frames 

body and drop down 

 turn sideways and remove through the front door.  Reinstate in reverse order but 

ensure the rear air box seats against the back of the stove with the back aerated bricks supporting it.   
 
Always check the flue is clear after a prolonged period of shutdown or non use. 
 
Vertical side flueways are cleaned through the top cleaning plugs along with the flue channels under the 
head of the stove through those self-same plugs and soot / deposits should be vacuumed out through 
the face lower cleaning plugs to remove the debris cleaned down.  These plugs must always be re-fitted 
firmly in place before lighting or whilst running the Ecco Stove.  The firebox door and ash pit door should 
remain closed at all times other than re-fuelling (fire box door) and ash pit door after following the 
lighting and re-fuelling procedures stated in these instructions. 
 
The grate should be de-ashed by raking through the fire box door to ensure combustion air can flow 
through the grate bars (only carry out these works when the stove is not alight). 
 
The stove is now ready for re-use after all cleaning plugs have been re-fitted. 
 
The door glass may be cleaned free of either grey transparent fly ash deposits or tar deposits from its 
inner surface with a proprietary glass cleaner available from your retailer.  
 

20. PAINT FINISHES 
 

Paint finishes on your Ecco Stove may produce a heavy chemical smell for a number of initial firings from 
being newly painted.  This is normal and will only last for a few high firings.  Ventilate the room well until 
the smell has cleared.  

 
 
 
 

Содержание 730EC2

Страница 1: ...the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt applian...

Страница 2: ...11 AIR CONTROLS a TERTIARY CONTROL b PRIMARY AIR c AIR WASH 12 FIRING THE STOVE a INITIAL FIRING b SUBSEQUENT FIRING c RE FUELLING AFTER STARTING 13 CONTINUOUS RUNNING 14 EXTRA CONTROLS 15 FUELS 16 RE FUELLING 17 TAR DEPOSITS 18 FLUE CONNECTION AND FLUE LININGS 19 CLEANING AND MAINTENANCE 20 PAINT FINISHES 21 ASSEMBLY A HEARTH LOAD BEARING B HEARTH DECCORATIVE 22 APPLIANCE ASSEMBLY 23 TECHNICAL A ...

Страница 3: ...s eccostove com W www eccostove com For all patents See Addendum I HEAT ENERGY STORED J CO CONCENTRATION 24 DUCTED WARM AIR 25 GENERAL A SAFE OPERATION DISTANCES COMBUSTABLE AND NON COMBUSTABLE B MODIFICATIONS C PARTS D CHIMNEY FIRES E SLOW HEAT RELEASE F CONTINUOUS BURNING G FAULT FINDING H WOOD DIMENSIONS 26 ECCO STOVE WARRANTY ...

Страница 4: ...e referring to National and European standards need to be complied with when installing this appliance Not every stove can be connected to every existing chimney Your installer must check the efficiency and performance of the chimney to ensure its suitability for us If the two are not compatible this can lead to poor burning and blackening of the glass and smoke leakage from the appliance The loca...

Страница 5: ...himney serving another unit Access must be provided for cleaning the chimney and stove connector pipe 5 GLASS Glass panel provided with your stove is deemed a consumable and may need to be replaced during the life of the stove Consumables are not covered by the manufacturers guarantee In the event of having to replace the glass in the stove please note that any fixtures should not be more than han...

Страница 6: ...sections must be replaced with like for like diameter rope or flat tape as fitted to the stove at the time of its construction Door ash pit cleaning plug and hob cleaning plug seals should be replaced when showing signs of wear or every two years whichever comes first Rope seals are not covered by the manufacturer s warranty 10 FINISHES On initial firing and perhaps three to five firings after the...

Страница 7: ...on air when the stove is started from cold or re fuelled with its body temperature below 150 C on the top plate The ash pit door must be drawn out to 1mm for 30 seconds then shut until the top plate has reached 150 C to 200 C and then closed see 11C ashpit drawer 11C SECCONDARY AIR AIRWASH After Stoves top plate has reached 150 C to 200 C the preset fixed Secondary air airwash control will continu...

Страница 8: ...f 1 8kg batches of wood for total 5 4kg The stove may be started with a firelighter or paper twists and kindling Start with 5kg kindling After kindling has begun thorough combustion about 5 minutes the stove should be loaded with 2 small split logs 70mm diameter to 300mm long stacked in the fire box see page 18 approximately 1 5kg The primary air ash pit front should be pulled out 1mm maximum for ...

Страница 9: ... tar build up will occur and subsequent blocking of the flue ways 13 CATALYSER The 730EC2 is fitted with a Catalyser in the head of the stove above the tube baffle system To install or replace reinstall the catalyser prior to fitting the tube baffle system lift the catalyser up into place followed by the stainless support frame Drop the stainless steel support frame down flat and the catalyser dro...

Страница 10: ...smoke The appliance must not be operated with air controls appliance dampers or door left open except as directed in the instructions ASH REMOVAL Ash removal must only be carried out when the stove is not alight as by removing the ash drawer would overfire the appliance To remove ash collected in the ash drawer simply pull out the ash drawer which may be fully extracted for emptying Always re fit ...

Страница 11: ...over Follow initial lighting procedures Smoke may escape the door if re fuelling is carried out on a bright or lively fire Open the door to the fire box slowly when re fuelling to minimise smoke spillage into the room as the door will create a vacuum drawing the smoke out of the fire box unless the flue ways are below 150 C UNDER NO CIRCUMSTANCES MUST THE STOVE BE OPERATED WITH THE DOOR OR AIR CON...

Страница 12: ...ctly to clay linings within chimneys unless those clay liners have a hot face lining fitted within in order to reduce condensation within the chimney flue 19 CLEANING AND MAINTENANCE Flue ways within the Ecco Stove should be cleaned two monthly in continuous combustion for which the stove should be let out not burning Cleaning access points are located on the stoves top sides 4 discs which must be...

Страница 13: ...deways and remove through the front door Reinstate in reverse order but ensure the rear air box seats against the back of the stove with the back aerated bricks supporting it Always check the flue is clear after a prolonged period of shutdown or non use Vertical side flueways are cleaned through the top cleaning plugs along with the flue channels under the head of the stove through those self same...

Страница 14: ...ool gloves and one thermometer are included HEARTH LOAD BEARING The Ecco Stove Model 730EC2 must stand on a load bearing hearth capable of carrying 550kg with an overall width of 730mm and depth of 575mm allowing 75mm gap behind the stove or to suit in country requirements if different from the above HEARTH DECCORATIVE Must extend 150mm either side or 300mm in front of the Ecco Stove as a minimum ...

Страница 15: ...are fitted to this part Ensure it is located on its domed carbide locating pips by shuffling to bed into place Ba Fit the cast iron grate into the recess within the Silicon Carbide grate section with the upstand to the back of the stove to retain the back baffle board C RIGHT SIDE This section to be stood firmly onto Part A using the cone shaped diablos to position accurately Ensure this section n...

Страница 16: ...stoves chosen location until held in position by the top section D LEFT AND RIGHT SIDES This section to be stood firmly onto Part A using the locating pips to position accurately Ensure this section neatly holds the joint seal into place Shuffle it to bed onto its carbide locating pips NOTE The tertiary air intake hole should be at the bottom and not the top of the back section This hole is to be ...

Страница 17: ...osition the vermiculite spacer blocks for 730EC Model flat against the back section such that the pre drilled vermiculite back baffle is spaced off the back section to allow an air flow behind them but are held at their front by the rear upstand on the cast iron grate Seal over with the white gunable mastic provided G DOOR SECTION Door section should now be lowered over the sides until it sits fir...

Страница 18: ... BAFFLE ASSEMBLY Position the steel baffle assembly with the shaped curve pointing down and as close to the glass of the door as possible No fixings should be used to ensure it can be replaced without dismantling the stove The assembly must sit over the vermiculite back boards The front of the baffle assembly curved front sits on the 2 pins which are inserted into the pre drilled 6mm holes in the ...

Страница 19: ...nce 550 kg The Ecco Stove must be installed onto a structural hearth capable of bearing this weight c Air Supply UK 27 5 cm sq outside UK to those countries local requirements Vents to be fitted to outside and positioned such that they are not liable to block Additional ventilation requirement may be needed if the stove is operated simultaneously with other heating appliances It is important to en...

Страница 20: ...in position for appearances only 25 GENERAL a Safe Operation The outside surface of the Ecco Stove will reach temperatures above 200 C on full firing and must not be touched as burning will occur Care must be taken In the event of overheating above 230 C ensure the fire door and ash pit door are fully closed in order to reduce the rate of combustion and slowly cool the stove a i Any combustible ma...

Страница 21: ...release heat slowly on a falling heat Should it be required this method of heating be continued a fresh fuelling may be undertaken and initial firing procedures followed and the method then repeated with two fills of fuel or more before the appliance is left to release its heat slowly f Continuous burning The Ecco stove may be run as a continuous heat producing appliance and after which may then b...

Страница 22: ...5 23 V2 P a g e 22 of 29 Ecco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com For all patents See Addendum i Tested technical data ...

Страница 23: ...on form must be completed and returned to the Company within 21 days of installation see last page This warranty is void if the appliance is stripped and re assembled 3 Warranty Period Silicon Carbide parts are warranted for 10 years from the date of purchase the date purchased from the Company Surface hairline cracks in the appliance provided component parts remain intact are deemed acceptable wi...

Страница 24: ... the use of wood logs on your Ecco Stove Coals or processed petro chemical fuels void the warranty as their use may produce blockage in flueways Wood logs must be seasoned dried up to 20 humidity to prevent premature blocking of the flueways Any signs of tarring within the Ecco Stove will identify the use of sub standard fuel 9 Rights This warranty does not affect your statutory consumer rights wh...

Страница 25: ...O STOVE MODEL E730EC2 ECCO STOVE SERIAL NUMBER INSTALLED BY ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER INSTALLERS REGISTERED BODY AND NUMBER DATE THE ECCO STOVE WAS INSTALLED SELLING AGENT DEALER COMPANY NAME ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER EMAIL ADDRESS DATE SOLD INSTALLATION DETAILS DISTANCE TO COMBUSTIBLES SIDES TOP FRONT REAR DISTANCE TO NON COMBUSTIBLES SIDES TOP FRONT REAR HEA...

Страница 26: ...ings or within the flue it can cause paint to bubble or flake on the stoves outer body This typically occurs after re firing when the stove has periods without use during the colder weather or when building works such as fresh plaster have taken place in and around the area the stove is situated In this event simply rub down the affected area with a light sandpaper or wire brush to remove loose ma...

Отзывы: