1.

Please take good care of the warranty card of the device. The warranty card contains the factory number (and important
technical parameters) of the device, which has important reference value for the user's future maintenance and new equipment.

2.

During the warranty period, if the DTU is damaged due to the quality of the product itself rather than man-made damage or
natural disasters such as lightning strikes, it enjoys free warranty; please do not repair by yourself, and contact our company if
there is a problem. Ebyte provides first-class After-sales service.

3.

Do not operate this DTU in the vicinity of some flammable places (such as coal mines) or explosive dangerous objects (such
as detonators for detonation).

4.

A suitable DC stabilized power supply should be selected, which requires strong anti-high frequency interference, small ripple,
and sufficient load capacity; preferably, it should also have over-current, over-voltage protection and lightning protection
functions to ensure that the DTU is normal jobs.

5.

Do not use it in a working environment that exceeds the environmental characteristics of the DTU, such as high temperature,
humidity, low temperature, strong electromagnetic field or dusty environment.

6.

Don't let the DTU continuously be in full load transmitting state, otherwise the transmitter may be burnt out.

7.

The ground wire of the DTU should be well connected with the ground wire of the external equipment (such as PC, PLC, etc.)
and the ground wire of the power supply, otherwise the communication interface will be burnt easily; do not plug or unplug the
serial port with power on.

8.

When testing a DTU, you must connect a matching antenna or a 50Ω dummy load, otherwise the transmitter will be easily
damaged; if the antenna is connected, the distance between the human body and the antenna should be more than 2 meters to
avoid injury. Touch the antenna when transmitting.

9.

Wireless data transmission stations often have different communication distances in different environments. The

Содержание E90-DTU-V8

Страница 1: ...E90 DTU 433L33 V8...

Страница 2: ...definition 7 4 2 RS232 Interface definition 7 4 3 RS485 Interface definition 7 5 Technical indicators 8 5 1 Model specifications 8 5 2 General specification parameters 8 5 3 Frequency range and chann...

Страница 3: ...production use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provi...

Страница 4: ...ission time which in turn reduces the possibility of being interfered thus improves the reliability and communication efficiency 1 2 Features All core components are originally imported our transceive...

Страница 5: ...rts 1 First step is to mount antenna then battery making sure the dial switch is on its right status User gets on the power by choosing either VCC GND or power adapter 2 Using USB RS232 converter or U...

Страница 6: ...gdu Ebyte Electronic Technology Co Ltd 3 achieved 4 User needs to open the mode switch first before link DTU with computer if the user want to modify parameters Firing up to configuration Tool modify...

Страница 7: ...stallation Specifications 3 1 Structure Pin NO Name Function Description 1 DB 9 female socket RS 232 interface Standard RS 232 interface 2 3 81 terminal block RS 485 power interface Standard RS 485 in...

Страница 8: ...ectronic Technology Co Ltd 5 5 RXD LED Receive LED Yellow blinks when receiving data 6 DC power interface Power interface In line round hole outer diameter 5 5mm diameter 2 5mm 7 DIP switch DIP switch...

Страница 9: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 433L33 V8_User Manual_EN Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 6 3 2 Dimension Unit mm...

Страница 10: ...f the power supply is OK DTU can use 8 28V DC power supply but it is recommended to use 12V or 24V DC power supply 4 2 RS232 Interface definition The DTU can be connected to the device via RS 232 usin...

Страница 11: ...nce Specifications Application Hz W km E90 DTU 433L33 V8 433 0 1 3 Strong penetration anti interference To the environment with small data long distance many obstacles Note Test condition in clear and...

Страница 12: ...ower the transmit power the closer the transmission distance but the working current won t be declined in exact proportion it is recommended to use the maximum transmit power 5 5 Air data rate Model D...

Страница 13: ...6 Operating mode DTU has four operating modes if low power consumption is not required normal communication is recommended to configure the data transceiver for the normal mode mode 0 The factory def...

Страница 14: ...11 7 Program the DTU 7 1 diagrammatic drawing Mode M1 M0 Description Mode 3 Sleep Mode Off Off Only be programmed using the configuration software in the current mode Note 1 programming can only be c...

Страница 15: ...he same area it is recommended that the communication frequency be separated by 2 5MHz TX power The output power is the power radiated to the outside In order to ensure the working efficiency it is re...

Страница 16: ...S485 410 441M 20 3 LoRa spread spectrum long distance anti interference E95 DTU 433L30 485 V8 RS485 410 441M 30 8 LoRa spread spectrum long distance anti interference E96 DTU 433L20 485 V8 RS485 410 4...

Страница 17: ...interference small ripple and sufficient load capacity preferably it should also have over current over voltage protection and lightning protection functions to ensure that the DTU is normal jobs 5 Do...

Страница 18: ...measured communication distance is not ideal it is recommended to analyze and improve the communication distance from the antenna quality and antenna installation method You can also contact support c...

Страница 19: ...Issued by V1 0 2022 08 17 Initial version XXN About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us...

Отзывы: