![Ebyte E90-DTU-V8 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ebyte/e90-dtu-v8/e90-dtu-v8_user-manual_4038418012.webp)
Chengdu Ebyte Electronic Technology Co.,Ltd.
E90-DTU (433L33)-V8_User Manual_EN
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd
9
5.3.
Frequency range and channels
Model
Default frequency
Frequency range
Channel spacing
Channels
MHz
MHz
MHz
E90-DTU
(433L33)-V8
433
410~441
1
32
,
half duplex
★
Note: In the same area when multiple data transceivers are communicating one to one at the same time, it is
recommended to set the channel spacing between each group of data transceivers at 2MHz or more.
5.4.
Transmit power level
Model
10mW
25mW
50mW
100mW
E90-DTU (433L33)-V8
√
√
√
√
★
Note: The lower the transmit power, the closer the transmission distance, but the working current won’t be declined in
exact proportion ,it is recommended to use the maximum transmit power.
5.5.
Air data rate
Model
Default air data
rate
Levels
Air data rate(bps)
bps
bps
E90-DTU
(433L33)-V8
2.4
6
0.3、1.2、2.4、4.8、9.6、19.2
★
Note: The higher the air data rate, the fast
er the transmission rate, the transmission distance is also closer; when the
rate meets the requirements, the lower air data r
ate, the better quality.
5.6.
Current parameters
Model
Transmitting current mA
Standby current mA
12V
24V
12V
24V
E90-DTU
(433L33)-V8
134
81
28
28
★
Note: It is re
commended to retain more than 50% of the current margin when selecting the power supply, which
will help the data tra
nsceiver to work steadily for a long time.
Содержание E90-DTU-V8
Страница 1: ...E90 DTU 433L33 V8...