Chengdu Ebyte Electronic Technology Co., Ltd.
E22-400T30S_User Manual _EN
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
17
3
WOR mode transceiver control
Only valid for mode 1;
1. In the receiving mode of wor, the module can
modify the delay time after wake-up, and the default
time is 0;
2. The receiving end needs to send the command C0
09 02 03 E8 in the configuration mode (C0 is the
write command, 09 is the address of the register
initiator, 02 is the length, 03 E8 is the set delay, the
maximum FFFF is 65535ms, set to 0 turns off the
wakeup delay.)
3. Data can be sent within the delay
0
WOR receiver (default)
Working in WOR monitoring mode, the
monitoring period is shown below (WOR
period), which can save a lot of power
consumption.
1
WOR transmitter
The transceiver of the module is turned on,
and when transmitting data, a wake-up code
for a certain period of time is added.
2
1
0
WOR cycle
Only valid for mode 1;
Period T= (1+WOR)*500ms, maximum 4000ms,
minimum 500ms;
The longer the WOR monitoring interval period, the
lower the average power consumption, but the
greater the data delay;
The sending and receiving parties must be consistent
(very important)
0
0
0
500ms
0
0
1
1000ms
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
07H
write
CRYPT
_H
key high byte (default 0)
Write only, read returns 0;
Used for encryption to avoid interception of air
wireless data by similar modules;
Inside the module, these two bytes will be used as
calculation factors to transform and encrypt the
wireless signal in the air.
08H
write
CRYPT
_L
Key low byte (default 0)
80H
~
86H
read
PID
Product information 7 bytes
Product information 7 bytes
7.3 Factory default parameters
Model
Factory default parameter values: C0 00 09 00 00 00 62 00 17 03 00 00
Module Model
Frequency
Address
Channel
Air Speed
Baud Rate
Serial Format
Transmit
Power
E22-400T30S
433.125MHz
0x0000
0x17
2.4kbps
9600
8N1
30dbm
Chapter 8 Use of Relay Networking Mode
No.