7.2 Wireless remote configuration function
The module supports remote configuration function, use the ZCL protocol to configure the Attribute under cluster 0xFC08 (need
to cooperate with Manufacture Code 0x2000), which can be modified.
AttrID
Descriptor
name
type of
data
operation
initial value
0x0000
Baud
baud rate
uint32
R
115200 (decimal)
0x0001
Target Addr
Transparent
transmission target
short address
uint16
RW
0xFFFF
0x0002
Target EP
Transparent
transmission target
port
uint8
RW
0xFF or 255
0x0003
Send Mode
Transparent mode
bool
RWP
0
0x0004
LP Level
low power mode
enum8
RP
0
0x0006
Modbus ID
Modbus number
uint8
RWP
0xFF
0x0010
User Attr 0
user-defined variable
0
uint32
RW
0x00000000
0x0011
User Attr 1
User-defined variable
1
uint16
RW
0x0000
0x0012
User Attr 2
User-defined variable
2
uint8
RW
0x00
0x0013
User Attr 3
User-defined variable
3
uint8
RW
0x00