4. Functional Introduction
The MESH network architecture is shown below
The biggest advantage of this module is that it can relay any data in the network. Any module can be relayed and
received at the same time. The module's data signal coverage is about 50 meters. The following is a functional schematic.
A->C 70M
C->E 70M
B->D 70M
Interpreting the simulation application scene above:
The distance from Module A to Module C is 70 meters, beyond 50 meters of our module's transmission distance, so
module A cannot send data directly to module C. If a module B is placed between module A and module C, the data will
be relayed by B and then received by module C.
Module A needs to send data to the whole thing.The network, modules B, C, D, E need to receive data from A, then
module A will send the data at the broadcast address(0XFFFF).
If module A needs to specify data issuance, All you need to do is write the address of module E at the address in the data