Chengdu Ebyte Electronic Technology Co.,Ltd.
E104-BT12LSP User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
18
Column: Reading values 8813, 8813 is small-end mode. Actual value is 1388, converted to
decimal value of 5000
4.2.1.14 Setting up LPN polling friend time
Operation
al code
Parameter
Request
0x0D
None
Respond
0x0D
Set time-out sleepout.
Example
Request
:
04 C0 0D TIME
Respond
:
05 40 0D TIME
Note
:
Default 2000
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: Set 5000 ms, convert 5000 to 16-digit value 1388. When you set it, you need to write
8813.
04 C0 0D 8813
4.2.1.15 Reading LPN polling friend time
Operation
al code
Parameter
Request
0x0E
None
Respond
0x0E
Set time-out sleepout.
Example
Request
:
04 C0 0E
Respond
:
05 40 0E TIME
Note
:
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: If the reading value is 8813, 8813 is small-end mode, the actual value is 1388,
converted to decimal value is 5000
4.2.1.16 Set LPN to Sleep Time without Networking
Operation
al code
Parameter
Request
0x0F
None
Respond
0x0F
Set time-out sleepout.
Example
Request
:
04 C0 0F TIME
Respond
:
05 40 0F TIME