background image

Chengdu Ebyte Electronic Technology Co.,Ltd.

E104-BT09 User Manual

Copyright ©2012–2023

Chengdu Ebyte Electronic Technology Co.,Ltd.

13

6.2.3 AT+FACTPRY Restore Factory Command

Command

Respond

AT+FACTPRY

DEVICE_NAME:EBYTEBLE MAC:40050238C1A4

Instructions:
1

After resetting, it will restart automatically;

2

During the process of restoring factory settings, any kind of reset is prohibited, and power off is prohibited before the

operation is completed;
3

RESTORE pin is low for 5 seconds, then restore the factory settings

6.2.4 AT+SAVE Save command

Command

Respond

AT+SAVE

DEVICE_NAME:EBYTEBLE MAC:40050238C1A4

Description

Save the setup parameters of the module, such as: Bluetooth name/MAC address, etc. After using this

command, the system will automatically software reset and restart, so that the parameters just set up are permanently
saved.

6.2.5 AT+DISCONNECT Disconnect Command

Command

Respond

AT+DISCONNECT

OK+DISCONNECT

Description: Disconnect the module from all external Bluetooth devices, if there is no connection then return the error
OK+DISCONNECT=ERROR.

6.2.6 AT+NAME Bluetooth broadcast name

Command

Respond

Query

AT+NAME

OK+NAME=[para]

Setting

AT+NAME=[para]

OK+NAME

Parameter

para

ASCII

Refers to the Bluetooth broadcast name

Description

Set the Bluetooth broadcast name, such as the module has been connected, you need to broadcast
the next time to take effect, such as permanently save the parameter need to send AT + SAVE,
otherwise it is only temporary effect, the default Bluetooth name is EBYTEBLE.

Example

Send: AT+NAME=ABC
Return: OK+NAME
Set Bluetooth broadcast name to ABC

Содержание E104-BT09

Страница 1: ...1 E104 BT09 User Manual TLSR8208B BLE5 0 Low Power SMD Bluetooth to Serial Module...

Страница 2: ...5 4 1 GENERAL BROADCAST MESSAGES 10 5 5 CONFIGURE 11 5 6 DATA INDICATION PIN 11 5 7 UUID DESCRIPTION 11 6 AT INSTRUCTION 12 6 1 AT COMMANDSDESCRIPTION 12 6 2 COMMAND CHART 12 6 2 1 AT TEST COMMAND 12...

Страница 3: ...ORD OVER THE AIR 18 7 QUICK USE 19 7 1 CONFIGURATION MODE QUICK START GUIDE 19 7 1 1 SERIAL PORT CONFIGURATION 19 7 1 2 AIR CONFIGURATION 19 7 2 DATA TRANSMISSION 21 7 2 1 AIR CONFIGURATION 21 8 COMMO...

Страница 4: ...ction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided a...

Страница 5: ...ealth care smart home appliances accessories and remote control automotive lighting industrial internet smart data acquisition intelligent control and other fields Maximum support baud rate 1000000bps...

Страница 6: ...rns out the module Blocking power dBm 0 Low probability of burnout in close proximity Operating temperature 40 85 Industrial Grade 2 2 Operating parameters Table 2 2 Working Parameter Table Main Param...

Страница 7: ...height 2 0 meters 11 5dBm airspeed 1Mbps Bluetooth Protocol BLE5 0 RF chip TLSR8208BER FLASH 128KB SRAM 16KB Communication Interface UART Package Patch type Form factor 13 19mm RF Interface On Board...

Страница 8: ...low level low power consumption mode serial port can not communicate Pull high to enter normal working mode serial port can communicate 14 VBAT VBAT Input Battery power support 1 8 V 4 2 V power suppl...

Страница 9: ...ption 5 1 Role Description Module Support Role Slave The module slave can be connected with other models of our Bluetooth products to support transmissions 5 1 1 Pragmatic 1 The module only supports s...

Страница 10: ...e There is no Bluetooth broadcast in this mode and the serial port cannot communicate 5 2 2 Wake up call computing The so called wake up mode refers to the module in this mode the module required peri...

Страница 11: ...tion 5 5 Configure The module supports two configuration methods serial configuration and over the air configuration These two configuration modes are basically the same before the air configuration m...

Страница 12: ...T instructions return results ending in r n except return to HEX AT instructions are automatically recognized in wake up mode and error instructions are transmitted as data 6 2 Command chart 6 2 1 AT...

Страница 13: ...ss etc After using this command the system will automatically software reset and restart so that the parameters just set up are permanently saved 6 2 5 AT DISCONNECT Disconnect Command Command Respond...

Страница 14: ...of the low bit in the front Example Send AT MAC 001122334455 Return OK MAC Set Bluetooth MAC address to 001122334455 6 2 8 AT BAUD Serial Baud Rate Command Respond Query AT BAUD OK BUAD para Setting A...

Страница 15: ...10 2 2 9 0 3 8 3 4 7 0 5 5 9 6 4 7 7 4 0 8 2 9 9 2 0 10 0 6 11 1 2 12 5 0 13 9 3 14 15 0 15 18 4 16 50 0 Description If you permanently save this parameter you need to send AT SAVE otherwise it will...

Страница 16: ...PARAM para Setting AT CON_PARAM para OK CON_PARAM Parameter para ASCII Bluetooth connection interval ms 20 50 100 Description Set the Bluetooth connection interval of the module such as permanently sa...

Страница 17: ...UUID para3 Minor UUID para4 RSSI Example AT BEACON 11223344556677889900112233445566 1111 2222 c7 OK BEACON Set UUID Major UUID Minor UUID RSSI parameters are 11223344556677889900112233445566 1111 2222...

Страница 18: ...tup AT UUID para1 para2 para3 Parameter para3 ASCII Corresponding UUID parameters Para1 ASCII Specific UUID A service uuid B slave uuid C master uuid D config uuid Para2 ASCII UUID Bits 0 16 bits 1 12...

Страница 19: ...guration Mode Quick Start Guide 7 1 1 Serial Port Configuration set XCOM string related configuration default configuration 115200 8 1 none no flow control such as Figure VII 1 XCOM parameter configur...

Страница 20: ...l Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 20 turn on the service for uuid this fff0 enable configuration channel notiy sends the authentication command at auth 123456 and the mo...

Страница 21: ...Transfer Modes Test conditions Prepare to support host mode module 1 in the example we use our E104 BT08 Test software XCOM Other parameters are configured by default 7 2 1 Air configuration 1 Power u...

Страница 22: ...host receives the data ABCDEFG as shown in Figure VII 7 Passthrough Diagram 8 Common problems 8 1 Unsatisfactory transmission distance When there are linear communication barriers the communication d...

Страница 23: ...h frequency device electrostatic sensitivity Please ensure that the installation and use of the process of humidity should not be too high part of the components for humidity sensitive devices If ther...

Страница 24: ...eak temperature Tp Peak temperature 220 235 230 250 Aveage ramp down rate Tp to Tsmax Average rate of descent 6 second max 6 second max Time 25 to peak temperature Time from 25 C to peak temperature 6...

Страница 25: ...1 CC2541 2 4G 0 I O 4 0 14 22 PCB Secondary Development E104 BT02 DA14580 2 4G 0 TTL 4 2 14 22 PCB Hardware Resources E72 2G4M04 S2B CC2640 2 4G 2 TTL 4 2 14 23 PCB IPX Secondary Development E104 2G4U...

Отзывы: