scan response is a broadcast message that replies after receiving a scan request from a host.
dvertising
fixed field
Len
Manufacturer field
Manufa data
020106
N
0xFF
Configurable, up to 26 bytes
For example
:
020106< Len >FF< Manufa data >
Figure V4 Broadcast data formats
Users can only configure Manufa data field data.
Scan response
Len
fixed
UUID
Len
fixed
Device name
0x03
0x03
FFF0
N
0x09
Configurable, up to 25 bytes
For example: 0303FFF0<len>09< Device name >
Figure V5 Scanning Response Data Format Table
Note: This data does not require user configuration.
5.5
Configure
The module supports two configuration methods: serial configuration and over-the-air configuration. These two
configuration modes are basically the same, before the air configuration must be through the AT + AUTH = 123456
authentication password, i.e., to the remote configuration service UUID input 123456, the module is allowed to use the
air configuration after the authentication is passed. The authentication period for over-the-air configuration is the current
connection, and if the device is disconnected and reconnected, it needs to be re-authenticated.
After the module is in the wake-up state, it is in the configuration mode by default, and can be configured directly
through the AT command.
5.6
Data Indication Pin
LINK pin, where a high level on the LINK pin indicates a connection and a low level indicates a disconnection;
5.7
UUID Description
Service UUID
FFF0