background image

Copyright ©2012–2019 , Chengdu Yibaite Electronic
Technology Co., Ltd

Chengdu Yibaite Electronic

Technology Co., Ltd.

Household manual

E 831-RTU (6060-

ETH).

Содержание 6060-ETH

Страница 1: ...Copyright 2012 2019 Chengdu Yibaite Electronic Technology Co Ltd Chengdu Yibaite Electronic Technology Co Ltd Household manual E 831 RTU 6060 ETH ...

Страница 2: ... switch DI input 24 4 3 IO Features 25 4 3 1 Pulse counting and counting zeroing 25 4 3 2 Automatic reporting of switch input DI 27 4 3 3 Switching output DO time setting 27 4 3 4 Restart the switching output status setting 29 4 4 Network related functions 29 4 4 1 Device MAC address reading 29 4 4 2 Device S N code reading 29 4 4 3 Network related functional parameters take effect command Etherne...

Страница 3: ...ave mode slave can cascade multiple devices via RS485 Support Reload touch button long press 5s Modbus device address RS485 serial port baud rate and check bit to restore factory settings Hardware watchdog with high reliability Multiple indicators show the working status The power supply has good overcurrent overvoltage anti reverse and other functions Note Customers can customize features such as...

Страница 4: ...chapter and follow the instructions to operate again will have a systematic understanding of the module product users can also choose the chapters you are interested in reading according to their needs For specific details and instructions please refer to the following sections 1 1 Port connection 1 1 1 RS485 connection 1 1 2 Switch input connection Copyright 2012 2019 Chengdu Ebyte Electronic Tec...

Страница 5: ...TU 6060 ETH via USB to RS485 The computer is connected to the E831 RTU 6060 ETH via a network cable Power supply E831 RTU 6060 ETH operates from DC 8 to 28V 1 2 1 RS485 Bus Control Select the appropriate port click Search and search for the device When you have searched for the device click Stop Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 5 ...

Страница 6: ... 6060 ETH User Manual At this time you can see the device address of the current device processing of the auto refresh and you can control the switching output and read the switching input Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 6 ...

Страница 7: ...2 168 4 101 and the subnet mask is 255 255 255 0 TCP server port number 8666 Right click the local connection settings THE IP of the computer 192 168 4 10 the subnet mask 255 255 255 0 Open the network port host computer set the port number and other parameters click Connect you can find that the device LINK light is lit Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 ...

Страница 8: ...lectronic Technology Co Ltd E831 RTU 6060 ETH User Manual Control DO 1 via the Modbus command 01 0 F 00 10 00 06 01 3F 1E 85 DO2 DO3 DO4 DO5 DO 6 Closed Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 8 ...

Страница 9: ...Chengdu Ebyte Electronic Technology Co Ltd E831 RTU 6060 ETH User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 9 ...

Страница 10: ...hernet port specifications RJ45 10 100Mbps Network Protocol IP TCP UDP ARP ICMP IPV4 IP acquisition equation Static IP DHCP Domain name resolution backing Hardware parameters Product size H W D 172 107 29mm Product weight 473 1 5g Working temperature 20 70 Storage temperature 40 85 Humidity at work 5 95 Storage humidity 1 95 Working voltage 8V 28V Data connector RS485 1200 115200bps Software param...

Страница 11: ...Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 11 Chengdu Ebyte Electronic Technology Co Ltd E831 RTU 6060 ETH User Manual 2 2 Dimensions interface description ...

Страница 12: ...etworkport Connect to the computer the computer side 1 NO 5 Relay 5 normally open pins Works with relay 5 common ends 2 COM 5 Relay 5 common end Uses with relay 5 NO NO pins 3 NC 5 Relay 5 normally closed pins Works with relay 5 common ends 4 NO 6 Relay 6 normally open pins Works with relay 6 common end 5 COM 6 Relay 6 common end Uses with relay 6 NO NO pins 6 NC 6 Relay 6 normally closed pins Wor...

Страница 13: ...ion with DIG 18 DIG The amount of on off is entered into the locality Can be used in pairs with DI 6 19 NC 1 Relay 1 normally closed pin Works with Relay 1 Common Terminal 20 COM 1 Relay 1 common end Uses with relay 1 NORMAL NORMALLY CLOSED pin 21 NO 1 Relay 1 normally open pin Works with Relay 1 Common Terminal 22 NC 2 Relay 2 normally closed pins Works with Relay 2 Common End 23 COM 2 Relay 2 co...

Страница 14: ...ted Green LED DI 4 DIG shorts lit up 7 DI 5 Switch input channel 5 is indicated Green LEDs DI 5 DIG shorts lit up 8 DI 6 Switch input channel 6 is indicated Green LED DI 6 DIG shorts lit up 9 DO 1 Relay 1 output indication Green LEDs NO 1 COM 1 closed lit 10 DO 2 Relay 2 output indication Green LED NO 2 COM 2 closed lit 11 DO 3 Relay 3 output indication Green LED NO 3 COM 3 closed lit 12 DO 4 Rela...

Страница 15: ... 1 0x02 10018 0x0011 1 DI2 switch input read only 10019 0x0012 1 DI3 switch input read only 10020 0x0013 1 DI4 switch input read only 10021 0x0014 1 DI5 switch input read only 10022 0x0015 1 DI6 switch input read only retain 40049 0x0030 1 DI1 pulse count value read only 0 65535 0x03 40050 0x0031 1 DI2 pulse count value read only 0 65535 40051 0x0032 1 DI3 pulse count value read only 0 65535 40052...

Страница 16: ... the network protocol parameters Read writ e TCPS 192 168 4 10 8886 40146 0x0091 2 Set up a registration package mode Read writ e 0 4 Close the enrollment package 0x00 40150 0x0095 42 Set up the registration package content Read writ e regist msg 40234 0x00E9 42 Set the heartbeat pack contents Read writ e heartbeat msg 40318 0x013D 2 Set the heartbeat packet mode Read writ e 0 1 Mesh heartbeat pac...

Страница 17: ...3 2 Modbus address table 1 default 1 2 2 Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 15 ...

Страница 18: ...00 4 19200 5 38400 6 57600 7 115200 3 4 RS485 Serial Port Check Digit Value Table 0 default No validation 1 Parity 2 Odd check 3 5 Configure parameters via host computer Select the Parameter Settings column to read parameters write parameters and implement specific functions see the product function introduction below Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 16 ...

Страница 19: ...Chengdu Ebyte Electronic Technology Co Ltd E831 RTU 6060 ETH User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 17 ...

Страница 20: ...the sending end will be discarded In slave mode the device can directly connect to the device in master mode through the 485 bus so that if the slave is not networked the network side can also access the slave data through the host 4 1 2 Host Mode In host mode register value is 0x00 network side or 485 bus side send side The data sent to the device meets the Modbus RTU Modbus TCP protocol and the ...

Страница 21: ...00 0011 and the six bits in the lower six bits represent the switching output state in order of DO6 DO5 DO4 DO3 DO2 DO 1 Modbus RTU protocol reads the switching output Send 01 01 00 10 00 06 BD CD Provision the ModBus address Functional codes The address where the switch starts The number of read switches CRC check digits Receivin g 01 01 01 03 11 89 Provision the ModBus address Functional codes T...

Страница 22: ...Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 19 ...

Страница 23: ...e logo Protocol identity length Unit identificatio n Functional codes The on off volume address Write a value Receivin g 00 01 00 00 00 06 01 05 00 11 FF 00 Transmit the logo Protocol identity length Unit identificatio n Functional codes The on off volume address Write a value Function code 0x0F Write DO2 DO3 switch output make NC2 COM2 Disconnected NO2 COM2 closed Disconnect NC3 COM3 NO3 COM3 clo...

Страница 24: ...4 2 2 Read the switch DI input Function code 02 read switch input state Address range 10017 0x0010 10022 0x0015 Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 20 ...

Страница 25: ... of read switches Receivin g 00 01 00 00 00 04 01 02 01 05 Transmit the logo Protocol identity length Unit identificatio n Functiona l codes The number of bytes returned Enter a value for the on off quantity 4 3 IO Features 4 3 1 Pulse counting and counting zeroing Pulse counts are not saved after a power outage and the pulse level hold time must be greater than 10ms to be valid The switching inpu...

Страница 26: ...Receivi ng 00 01 00 00 00 07 01 03 04 00 10 00 03 Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 21 ...

Страница 27: ...0a Transmit the logo Protocol identity length Unit identificatio n Functiona l codes address Write a value 4 3 2 Automatic reporting of switch input DI The automatic reporting function of the switching input is to transmit the changed value when the switching volume changes You can choose to transfer via RS485 or ETH also You can turn off the automatic escalation feature The modbus register corres...

Страница 28: ...ime corresponding to the Modbus register 40083 0x0052 with a value range of 300 65535ms if the value is lower than 300ms the default switching output is closed to a hold state that is the switching output remains held after it is closed Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 22 ...

Страница 29: ...k related functions 4 4 1 Device MAC address reading Modbus RTU protocol write register Send 01 03 00 61 00 03 54 15 Provision the ModBus address Functional codes The start address The number of read registers CRC check digits Receivin g 01 03 06 1C C0 BB FF 16 53 Provision the ModBus address Functional codes The number of word sections Read the value CRC check digits Modbus TCP protocol write reg...

Страница 30: ...0 0B 01 03 08 21 Transmit the logo Protocol identity length Unit identificatio n Functiona l codes The number of word sections Read the value Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 23 55 50 05 00 13 19 14 ...

Страница 31: ...Unit identificatio n Functiona l codes address Write a value In particular the Ethernet component can be restarted by writing a value of ox00 01 to the address ox 00 67 and the restart must be performed after configuring the Ethernet related parameters order otherwise the configured parameters do not take effect 4 4 4 WAN port IP information configuration Modbus RTU protocol write WAN port IP regi...

Страница 32: ... ing 00 01 00 00 00 15 01 10 00 6B 00 07 Transmit the logo Protocol identity length Unit identificatio n Functional codes address Register length Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 24 ...

Страница 33: ...TCP protocol write register S e n d 00 01 00 00 00 0F 01 10 00 79 00 04 08 3D 8B 02 45 C0 A8 04 02 transm it logoty pe agree ment logoty pe length Unit identificati on functio n yard address Register length The number of word sections Write a value Receiv ing 00 01 00 00 00 0F 01 10 00 79 00 04 Transmit the logo Protocol identity length Unit identification Functional codes address Register length ...

Страница 34: ...smit the logo Protocol identity length Unit identificati on Functio nal codes addres s Register length The number of word sections Write a value Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 25 ...

Страница 35: ...0 Transmit the logo Protocol identity length Unit identification Functional codes address Write a value Description 00 00 disables the enrollment package mechanism and a value of 00 01 indicates that only one user defined enrollment package is sent the first time the server is linked 00 02 Indicates that there is only a 6 byte MAC registration packet sent when first linked to the server and 00 03 ...

Страница 36: ...Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 26 ...

Страница 37: ...e heartbeat packet mode Modbus RTU protocol write register Send 01 06 01 3D 00 00 19 FA Provision the ModBus address Functional codes address Write a value CRC check digits Receivin g 01 06 01 3D 00 00 19 FA Provision the ModBus address Functional codes address Write a value CRC check digits Modbus TCP protocol write register Send 00 01 00 00 00 06 01 06 01 3D 00 00 Transmit the logo Protocol iden...

Страница 38: ...es address Register length CRC check digits Modbus TCP protocol write register S e n d 00 01 00 00 00 31 01 10 00 E9 00 15 2A 00 28 41 42 43 68 23 67 AA 00 2A 00 30 00 00 00 00 00 00 00 00 00 00 00 00 11 00 22 00 33 Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 27 ...

Страница 39: ... 00 00 00 00 00 00 00 00 4 4 11 Set the heartbeat packet time Modbus RTU protocol write register Send 01 06 01 41 01 AA 59 CD Provision the ModBus address Functional codes address Write a value CRC check digits Receivin g 01 06 01 41 01 AA 59 CD Provision the ModBus address Functional codes address Write a value CRC check digits Modbus TCP protocol write register Send 00 01 00 00 00 06 01 06 01 41...

Страница 40: ...Send 00 01 00 00 00 06 01 06 01 49 00 00 Transmit the logo Protocol identity length Unit identificati on Function al codes address Write a value Receivin g 00 01 00 00 00 06 01 06 01 49 00 00 Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 28 ...

Страница 41: ...number of word sections Write a value Receiv ing 00 01 00 00 00 0D 01 10 01 4F 00 03 Transmit the logo Protocol identity length Unit identification Functional codes address Register length Description 02 D1 indicates how many seconds after the TCP link has no data packet transmission initiated probe packets and 00 00 indicates that the KeepAlive feature is turned off with a value of 2 7200 seconds...

Страница 42: ...n g 00 01 00 00 00 06 01 06 01 5D 11 A1 Transmit the logo Protocol identity length Unit identificati on Function al codes address Write a value Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 29 ...

Страница 43: ...ength Unit identificati on Function al codes address Write a value Descrip tion 00 00 Indicates cloud pass through off and a value of 00 01 indicates on 4 4 16 Set a timeout during the restart Modbus RTU protocol write register Send 01 06 01 63 FF A0 39 A0 Provision the ModBus address Functional codes address Write a value CRC check digits Receivin g 01 06 01 63 FF A0 39 A0 Provision the ModBus ad...

Страница 44: ...ctronic documents if necessary please come to download from our company official website I addition if it is not a special request of the user when the user orders in batches we only provide product manuals according to a certain propo nrtion of the order quantity and not every digital transmission station is equipped one by one please understand 1 0 Initial version 1 1 2019 8 14 Format revision l...

Отзывы: