background image

 

EBTRON • 1663 Hwy. 701 S., Loris SC 29569 • Toll Free: 800.2EBTRON (232.8766) • Fax: 843.756.1838 • Internet: EBTRON.com 

 

IG_GTM

1

1

6

B_

R1

A

 

 

  

G

OLD 

S

ERIES 

GTM116-B T

RANSMITTER

 

a measurable difference! 

EBTRON 

Table

 

of

 

Contents

 

 

1

 

GTM116

 

TRANSMITTER

 

INSTALLATION

 

.....................................................................................................................

 

4

 

1.1

 

GTM116

 

Mechanical

 

Dimensions

 

.......................................................................................................................

 

4

 

2

 

GTM116

 

TRANSMITTER

 

INTERIOR

 

VIEW/FEATURES

 

..................................................................................................

 

5

 

3

 

GTM116

 

TRANSMITTER

 

POWER

 

AND

 

SENSOR

 

CONNECTIONS..................................................................................

 

6

 

3.1

 

Power

 

Transformer

 

Selection

 

.............................................................................................................................

 

6

 

3.2

 

Connecting

 

Power

 

to

 

the

 

Transmitter

 

................................................................................................................

 

6

 

3.3

 

Connecting

 

Bleed

 

Sensors

 

to

 

the

 

Transmitter

 

......................................................................................................

 

7

 

4

 

GTM116

 

ANALOG

 

OUTPUT

 

AND

 

NETWORK

 

CONNECTIONS

 

.....................................................................................

 

8

 

4.1

 

GTM116

 ‐ 

ANALOG

 

OUTPUT

 

WIRING

 

.................................................................................................................

 

8

 

4.2

 

GTM116

 ‐ 

ETHERNET

 

NETWORK

 

WIRING

 

CONNECTIONS

 

..................................................................................

 

9

 

4.2.1

 

GTM116

 ‐ 

Connecting

 

to

 

an

 

Ethernet

 

Network

 

...........................................................................................

 

9

 

4.3

 

GTM116

 ‐ 

Transmitter

 

Setup

 

for

 

Ethernet

 

Network

 

Operation

 

.........................................................................

 

9

 

4.3.1

 

GTM116

 ‐ 

Selecting

 

Static

 

or

 

Dynamic

 

IP

 

Settings

 

.......................................................................................

 

9

 

4.3.2

 

GTM116

 ‐ 

Setting

 

Ethernet

 

Transmitter

 

IP

 

Address

 

....................................................................................

 

9

 

4.3.3

 

GTM116

 ‐ 

Setting

 

Subnet

 

Mask

 

...................................................................................................................

 

9

 

4.3.4

 

GTM116

 ‐ 

Setting

 

Gateway

 

IP

 

......................................................................................................................

 

9

 

4.3.5

 

GTM116

 ‐ 

Setting

 

BACnet

 

Protocol

 

Mode

 

...................................................................................................

 

9

 

4.3.6

 

GTM116

 ‐ 

Setting

 

Device

 

Instance

 

Number

 

.................................................................................................

 

9

 

4.3.7

 

GTM116

 ‐ 

Resetting

 

Communications

 

Options

 

to

 

Factory

 

Default

 

Values

 

................................................

 

10

 

5

 

GTM116

 

TRANSMITTER

 

START

UP,

 

INITIALIZATION

 

AND

 

SETUP

 

MENUS

 

...............................................................

 

11

 

5.1

 

Changing

 

the

 

System

 

of

 

Units

 ‐ 

IP

 

or

 

SI

 

Units

 

...................................................................................................

 

11

 

5.2

 

GTM116

 

Transmitter

 

Calibration

 

......................................................................................................................

 

11

 

5.3

 

GTM116

 

LCD

 

Display

 

Notifications

 

...................................................................................................................

 

11

 

5.4

 

Factory

 

Default

 

Menu

 

Settings

 

for

 

GB1

 

Bleed

 

Sensors

 

.....................................................................................

 

12

 

5.5

 

GTM116

 

Changing

 

Factory

 

Default

 

Setup

 

Menu

 

Settings

 

................................................................................

 

13

 

5.5.1

 

Setup

 

Menu

 

Options

 

..................................................................................................................................

 

13

 

5.5.2

 

Selecting

 

Airflow

 

or

 

Pressure

 

Measurement

 

Type

 

....................................................................................

 

13

 

5.5.3

 

Selecting

 

Actual

 

and

 

Standard

 

Output

 

Measurement

 

Type

 

......................................................................

 

13

 

5.5.4

 

Output

 

Scaling

 

...........................................................................................................................................

 

13

 

5.5.5

 

Locking

 

the

 

Configuration

 

Settings

 

............................................................................................................

 

13

 

5.6

 

GTM116

 ‐ 

Alarm

 

Features

 

.................................................................................................................................

 

14

 

5.6.1

 

Average

 

Alarm

 

(AO2

 

ASGN=ALRM)

 

............................................................................................................

 

14

 

5.6.2

 

Trouble

 

Alarm

 

(AO2

 

ASGN=TRBL)

 

..............................................................................................................

 

14

 

5.6.3

 

No

 

Fault

 

(NO

 

FAULT=HI)

 

............................................................................................................................

 

14

 

5.6.4

 

Alarm

 

Indications

 

.......................................................................................................................................

 

14

 

5.6.5

 

Low

 

Alarm

 ‐ 

“LO

 

ALRM=

 

ON”

 

.....................................................................................................................

 

14

 

5.6.6

 

High

 

Alarm

 ‐ 

“HI

 

ALRM=

 

ON”

 

.....................................................................................................................

 

14

 

5.6.7

 

Trouble

 

Alarm

 ‐ 

“AO2

 

ASGN=TRBL”

 

...........................................................................................................

 

14

 

5.7

 

GTM116

 ‐ 

Analog

 

Output

 

Type

 

Selection

 

and

 

Setup

 

........................................................................................

 

15

 

5.7.1

 

GTM116

 ‐ 

Converting

 

Analog

 

Output

 

Signal

 

Values

 

to

 

Airflow

 

and

 

Temperature

 

.....................................

 

15

 

5.7.2

 

GTM116

 ‐ 

AO1/AO2

 

OUTPUT

 

TEST

 ‐ 

Sending

 

a

 

Test

 

Output

 

Signal

 

to

 

the

 

Host

 

Control

 

System

 

.............

 

15

 

5.8

 

Viewing

 

Sensor

 

Data

 

.........................................................................................................................................

 

16

 

5.8.1

 

Viewing

 

Sensor

 

Data

 

on

 

the

 

Local

 

LCD

 

Display

 

..........................................................................................

 

16

 

5.8.2

 

Viewing

 

Sensor

 

Data

  

via

 

BACnet

 

,

 

Modbus

 

networks

 

or

 

via

 

EB

Link

 

Reader

 

.............................................

 

16

 

5.8.3

 

Sensor

 

Addressing

 

......................................................................................................................................

 

16

 

6

 

SETUP

 

MENUS

 

..........................................................................................................................................................

 

16

 

7

 

WIRING

 

DIAGRAM

 

....................................................................................................................................................

 

16

 

APPENDIX

 

A

 ‐ 

ADVANTAGE

 

3

 ‐ 

BLEED

 

SENSOR

 

SETUP

 

MENUS

 

....................................................................................

 

17

 

APPENDIX

 

B

 ‐ 

GTC116

 

WIRING

 

DIAGRAM

 

...................................................................................................................

 

17

 

 
 
 

Содержание Advantage III Gold Series

Страница 1: ...rflow Sensors Combination Ethernet Network Output and Dual Analog Output Document Name IG_GTM116 B_R1B a measurable difference EBTRON BACnet is a registered trademark of ASHRAE ASHRAE does not endorse...

Страница 2: ...TER START UP INITIALIZATION AND SETUP MENUS 11 5 1 Changing the System of Units IP or SI Units 11 5 2 GTM116 Transmitter Calibration 11 5 3 GTM116 LCD Display Notifications 11 5 4 Factory Default Menu...

Страница 3: ...re 4 Type B Transmitter Connector Panel Detail 7 Figure 5 Connector Detail 7 Figure 6 GTM116 Combination Analog Ethernet Transmitter Interior Detail 8 List of Tables Table 1 GTM116 Power Transformer S...

Страница 4: ...in 50 8 mm to each side and 3 5 in 88 9 mm below the transmitter to allow for cover removal sensor connections and heat dissipation Locate the transmitter in a location that can be reached by all conn...

Страница 5: ...ed LCD contrast Transmitter status LED Green 1 second flash normal 2 second flash for fault High accuracy A D converter Gold plated interconnects to optional output cards Positive locking cable recept...

Страница 6: ...VA Req 1 12 5 14 2 13 6 15 3 13 7 15 4 14 8 16 3 2 Connecting Power to the Transmitter Connect 24 VAC power to the large two position power input terminal labeled POWER on the upper right hand side o...

Страница 7: ...de a drip loop at the transmitter if there will be the potential for water runoff or condensation along the bleed sensor cable s Bleed sensor cable plugs are keyed as shown below Line up plug with rec...

Страница 8: ...o wire the analog outputs slide the cover plate up and off of the enclosure Ensure that the power switch is in the OFF position Connect signal wires for airflow rate or equivalent differential pressur...

Страница 9: ...digit address segment that is under change Change the blinking segment by pressing the UP or DOWN buttons to arrive at the desired segment setting Depress the ENTER key to set this segment and to mov...

Страница 10: ...nsert 1 Flow 30019 30020 Insert 4 Flow 4 30021 30028 float F Temperature Traverse 20 to 160 30021 30022 Insert 1 Temp 30027 30028 Insert 16 Temp 4 30029 30030 float Sq Ft Area 0 to 100 4 300202 word F...

Страница 11: ...s are shown in IP System Of Units When SI System of Units is selected the units of measure abbreviations used in the menus is shown in Table 5 IP System of Units Description SI System of Units Descrip...

Страница 12: ...set factor 0 000 0 000 AO2 SGNL Output 2 signal voltage or mA temperature or alarm mA see alarms mA see alarms AO2 MS Output 2 signal minimum scale 20 F 30 C AO2 FS Output 2 signal full scale 160 F 70...

Страница 13: ...desired the output can be set to provide standard airflow measurement units displayed as SCFM and SFPM which provides measurements that are corrected to standard conditions 5 5 4 Output Scaling EBTRON...

Страница 14: ...and AO2 alarm output indications User can select either or both of the two Average Alarms or the Trouble Alarm 5 6 5 Low Alarm LO ALRM ON The Low Alarm is activated when the average airflow falls belo...

Страница 15: ...ntrol system To set a fixed output signal for airflow and temperature navigate to the OUTPUT TEST submenu in the TOOLS menu OUT1 and OUT2 tests are independently accessed and the output will maintain...

Страница 16: ...odbus networks or via EB Link Reader Airflow and temperature of individual sensors can be read across BACnet or Modbus networks or downloaded directly to an EB Link Reader if the infra red EB Link opt...

Страница 17: ...cters for blank or unwanted text EXT CABLE 0 SET EXT CABLE EXT CABLE 0 LCD TRBL ON Set measurement mode to AIRFLOW MEAS PRESS LCD DSPL BOTH SETUP Instruction text USE AND ENT then NAME _ GENERAL SET O...

Страница 18: ...ate this setting is fixed and cannot be modified AO1 ASGN iWG AO1 UM FIXED The text AO1 UM FIXED flashes to indicate that this setting is fixed and cannot be modified ANALOG OUT AO1 ASGN FLOW SET AO1...

Страница 19: ...ve to right and ESC to move to left Set network device instance number Set network protocol type Enter gateway IP address use up down arrow buttons to select value and press ENT to move to right and E...

Страница 20: ...low alarm setpoint Units based on ALARM UM DELAY 2 MIN SET DELAY DELAY 2 MIN Enter alarm delay RESET AUTO SET RESET RESET AUTO Set alarm RESET AUTO will clear once the alarm is not active MANUAL requi...

Страница 21: ...Adjust Wizard will now be engaged as outlined in the following steps The GAIN and OFF values will be updated and PRESS ADJ ON will be set if the wizard is successfully completed OF PRESS 2 OUT2 TEST...

Страница 22: ...RESET ADJ NO RESET ALL NO Sets security level to MED In this mode a user defined code is specified In the event of loss of code contact EBTRON for a unique code for this transmitter to unlock and rese...

Страница 23: ...te 2 L2 L1 POWER 24VAC IN OUT 1 AIRFLOW PRESSURE OUTPUT SIGNAL 1 2 COM ANALOG OUTPUT OUT 2 TEMP OR ALARM OUTPUT SIGNAL ANALOG BAS INTERFACE OUT 2 can be set as an analog Temperature Alarm or Trouble o...

Страница 24: ...1663 Hwy 701 S Loris SC 29569 Toll Free 800 2EBTRON 232 8766 Fax 843 756 1838 Internet EBTRON com IG_GTM116 B_R1A GOLD SERIES GTM116 B TRANSMITTER a measurable difference EBTRON a measurable differen...

Отзывы: