background image

PX200N_Manual_en-1.11i7 

Page 46 / 58 

 

7.11.

 

DEVICE MONITOR 

 

 

 
“Device Monitor” provides real-time information on device state. To use this function 
device must be connected to PC computer with LX-DATA cable (using DEBUG plug). 
Correct RS232 port must be chosen in “Port” field. “Device monitor” provides 
following information: 

 

AC power indication  

 

Battery power indication  

 

PSTN line indication  

 

GSM network signal level indication 

 

Bit-Error-Rate level measuring 

 

Inputs and outputs state monitoring 

 

Type or serial number of device 

 

Firmware and hardware revision 

 

Device time 

These parameters are also shown in LOG window in text style. All data can be saved 
to file. 

 

Note: Outputs OUT1 and NC-NO-C in the Device Monitor window are presented as, 
respectively, OUT1 and OUT2. 

Содержание PX200N

Страница 1: ...GPRS TRANSMITTER PX200N Installation and programming manual Firmware version 1 11 Issue 7 GPRS transmitter configurator version 1 2 0 Release date 18 03 2010 ...

Страница 2: ...oes not grant any guarantee both expressed or implied including but not limited to any understood guaranties in respect of merchantability and any warranty of fitness for a particular purpose unless required with effective legal provisions The manufacturer reserves the right to amend this document or withdraw it any time without prior notice Policy of the device manufacturer is to constantly devel...

Страница 3: ...t settings 19 6 3 13 Help About program 19 7 PROGRAMMABLE PARAMETERS 20 7 1 ACCESS 20 7 1 1 Parameters 20 7 1 1 1 Device mode 20 7 1 1 2 GPRS test time 21 7 1 1 3 SMS mode after unsuccessful attempts 21 7 1 1 4 SMS test time 21 7 1 1 5 Server phone number 21 7 1 1 6 Send events via SMS immediately 21 7 1 2 APN Parameters 21 7 1 2 1 APN 21 7 1 2 2 User ID 21 7 1 2 3 User password 22 7 1 2 4 DNS1 an...

Страница 4: ...7 5 1 SMS Authorized phones 32 7 5 2 GSM modems authorized phones 33 7 5 3 Validity period of outgoing SMS messages 33 7 5 4 SMS limits 33 7 6 SMS NOTIFICATIONS 34 7 6 1 Phone numbers 34 7 6 2 Events 35 SMS user tests 36 7 6 3 Status 36 7 6 4 SMS Forward 37 7 7 LINK CONTROL 38 7 7 1 GSM 38 7 7 2 GPRS 39 7 8 RS 232 40 7 8 1 Serial port settings 40 7 8 2 Buffer flushing 40 7 8 3 Advanced port option...

Страница 5: ...MMING 49 8 2 1 The first programming of device 50 8 2 2 Reprogramming of device 50 9 RECEIVING OF SMS MESSAGE 51 9 1 NEW PROTOCOL 51 9 2 OLD PROTOCOL 53 10 LED DIODES INDICATION 54 10 1 LOGGING TO GSM NETWORK 54 10 2 GSM RANGE 54 10 3 DATA TRANSMISSION 55 10 4 RECEIVING OF DTMF DATA 55 10 5 PROGRAMMING 56 10 6 FIRMWARE UPDATING 56 10 7 SIM CARD ERROR 57 10 8 SLEEP MODE 57 10 9 SYSTEM ERROR 57 11 C...

Страница 6: ...municator This provides for a cheap system of data transmission Communication with a monitoring station follows by GPRS SMS mode This device provides an opportunity to send text messages to private mobile phones An advanced encoding methods like a 256 bits encoding key and AES Advanced Encryption Standard provides for security of data transmission As a result reception of this transmission is poss...

Страница 7: ...S Remote CSD Locally from PC with the use of software and RS 232 link Security SMS GPRS transmission AES encoding Sabotage OUT1 OC type Additional NC NO C relay Output current Max 1A Max 100mA Voltage supply 18VAC 16 20VAC Current consumption average max 80mA 300mA 18VAC Dimension 141mm x 73mm x 35mm Charge current Max 220mA Charge voltage 13 8V Used batteries Acid leaded 12V Battery failure volta...

Страница 8: ...SEMBLY AND WIRING PROG BATTERY 12V 1 2Ah TRANSFORMER 230V AC TAMPER OUTPUT OC TYPE RELAY OUTPUT 1A 125V 8 INPUTS SIM CARD GSM MODULE RJ45 DB 9 SERVICE CABLE OR DATA CABLE PC PHONE LINE DTMF DIALER CONTROL PANEL RST ERROR DTMF STATUS OK PRG ...

Страница 9: ...ected to GND terminal NC NO C Additional output indication relay It may control external device During activation disconnects C terminal from NC and connects C to NO terminal OUT1 Type OC sabotage output It may control external device Provides ground during activation 12V Supply voltage output Provides up to 200mA RING TIP Terminals for an PSTN telephone R1 T1 Connection to alarm control panel pho...

Страница 10: ...M card number with SMS parameters related to connection of device to communication server OSM 2007 d waiting for moment when device indicates connection to server Note Connection to server is possible if the device was registered into it Registration procedure has been described in OSM 2007 Operation Manual e complete remote programming with GPRS transmitters configurator SMS text message shall pr...

Страница 11: ...00N_Manual_en 1 11i7 Page 11 58 Exemplary SMS is as follows if we use public network and provide server address as IP 1111 SERVER 89 123 115 8 PORT 6780 APN general t mobile uk UN PW Where space character ...

Страница 12: ...ted in particular to false alarms a device possesses a programmable analysis of inputs All inputs respond only to states change which means that transmitting will follow only if an active state is on input and maintains during programmed minimum time Maintenance of active state longer than a minimum time will result in single indicating Another input activation another transmitting is possible onl...

Страница 13: ...ming it is necessary to insert SIM card prior to sending configuration settings In this situation SIM card with switched off PIN code shall be used or before card inserting PIN code shall be changed with mobile phone 6 2 COMPUTER REQUIREMENTS Minimum requirements for computer system where configuration software is to be installed Hardware o Processor Pentium II 400 Mhz o 64 MB RAM o 1 GB HD o CD R...

Страница 14: ...w Opens new set of parameters Editing of configuration parameters is possible Select type of device PX200N 6 3 2 File Open If file contains saved settings they may be used to program next device Firstly a catalogue where file has been saved shall be chosen and then name of file shall be provided Obtained data collection may be modified by the user Any amendments are effective if send to device ...

Страница 15: ...tions Before programming of devices a connection type shall be defined It is possible to do it with two methods locally remotely 6 3 5 1 Local connection Local connection means that configuration software namely computer on which is installed is directly connected to proper terminal of transmitter Connection is possible owing to special wire and through RS 232 serial port To program device or make...

Страница 16: ...dow shall appear Define Name of connection e g Remote Select name of analyzer e g Primary Enter analyzer address e g 87 128 125 8 Enter port on which analyzer operates e g 7000 Click on Add button to confirm settings Connections shall be saved and inserted in table From this time on program shall enable remote connection to device and reading and saving of parameters in memory shall be possible No...

Страница 17: ...um one GSM modem is connected If device has been entered onto server list factory number and SIM card telephone number See OSM 2007 Operation Manual it is possible to use link via OSM It is possible if device is not connected to the OSM 2007 via GPRS During programming procedure with GPRS link See above a question will be displayed if user want to use a modem connected to the server After confirma...

Страница 18: ... clause 6 3 3 and use for other devices To use this function it is necessary to define type and parameters of connection E g for local connection the following view is displayed where Connection kind serial port to which module is connected Access code service code of transmitter Detailed description of connections configuration is included in clause 6 3 5 6 3 9 Operations Send This function is an...

Страница 19: ...e default settings If operation Read finishes with error message e g if access code is unknown it is possible to come back to default settings by selecting Restore default settings e Do you want to overwrite current configuration with default values After confirming the following window shall appear This operation is possible only with local connection After operation completing device parameters ...

Страница 20: ...1 Device mode Depending of user preferences a device may operate in 1 out 4 modes available from scrolled list o GPRS SMS GPRS standard transmission TCP IP Protocol and if any problems follow with this link it automatically SMS mode will follow o SMS Transmission only in SMS mode without trial to establish GPRS link o GPRS GPRS standard transmission TCP IP Protocol and in case of any problems with...

Страница 21: ...between tests time in minutes or completely interlocking of this option 7 1 1 5 Server phone number If GSM modem is connected to server application e g OSM 2007 enter in this field its number Any SMS will be sent to this number if transmitter has got problems with GPRS transmission If this field is left blank or 0 was entered the transmitter will be operating exclusively in GPRS mode Note This fie...

Страница 22: ...alled e g 89 123 115 8 This address may be provided in domain name of server e g modul gprs com In this case it is required to provide minimum one address of DNS server 7 1 3 2 Server port It determines server port that was selected in server for collection of data from transmitter 7 1 3 3 Interval between subsequent connection attempts Programmable and equipped with SIM card device will try to ma...

Страница 23: ...If device can not connect to primary server defined this after exhaustion for him number of attempts it will begin realizing the procedure of connecting to backup server We in this place define space of time in seconds after which test will connecting renewed if previous finished with failure 7 1 4 4 Number of connection attempts In this field you determine how often device will try to make connec...

Страница 24: ...de 2222 7 1 5 3 PIN of SIM card As a device operates via GSM network SIM card is indispensable and it may be received from phone operator Before the first use PIN code of SIM card shall be programmed for operation in given transmitter PIN code is indispensable for automatic system launching In case of card without PIN code it is possible to enter any value e g 0000 If you enter wrong PIN number af...

Страница 25: ...ter operates pursuant to requirements of the user All inputs of the device are 24 hour alarm inputs 7 3 1 Inputs configuration For every input the following settings shall be determined respectively 7 3 1 1 NC NO This parameter allow for setting of constant input Change of this state results in sending information on alarm Allowable NC and NO input NC input shall be shorted to ground Actuation fol...

Страница 26: ... option you can lock any input of module and as a result condition changes on this input will be ignored and will not be reported to monitoring station Lock may be persistent or temporary In case of temporary lock user can set lock time and number of input state changes after which lock occurs Lock time is counted from first input state change More detailed information about input locks is shown o...

Страница 27: ...n of power for module or remote command which switches output off o Monostable connection follows for time defined by user every 100ms 7 3 2 2 Conditions Defines conditions for activating both of outputs User can set following conditions No connection to server immediately after detection No GSM signal immediately after detection Detection of incoming call from defined telephone number Dependent o...

Страница 28: ... Advanced outputs control The user is able to determine an alternative course of action to go over basic outputs configuration function described in 7 3 2 Outputs In the Advanced outputs control you may define separately the behavior of each of the outputs depending on events taking place Advanced outputs control differs from the existing basic Outputs configuration by o it is possible not only to...

Страница 29: ...utput will be permanently turned on o Turn on output temporarily output will be turned on for an amount of time specified by parameter 7 3 3 2 Time of output activation o Turn off output output will be turned off Press the Reset button to assign the action Do Nothing for each event The output state does not change if the current state of the output coincides with the result of the action 7 3 3 2 T...

Страница 30: ...tate from action to rest normalization To transmit any signal you should only click it proper square on your right Click on Clear button to remove all marked signals Click on Invert button to change markings to contrary 7 4 2 SMS On SMS Off In this column you define signals that may be reported at monitoring station with SMS messages when there is no connection with server over GPRS There is possi...

Страница 31: ...teristics of the battery Sleep mode ensures reliable operation of the device when the battery is the only source of power at the time If the option Sleep when the battery voltage less than will remain unchecked transmitter will work as long as it allows the battery This may adversely affect the capacity of the battery for a further period of use as well as cause a generation of false alarms Transi...

Страница 32: ... that are on the list It is possible to list up to 5 phone numbers Select Allow chosen to get access to edition window Enter another numbers and click on Add button to send them to the below table Position cursor on line with number and click on Remove to remove number from table Click on Remove all to remove all numbers from table Note a authorizing of coming SMS comes through comparing number of...

Страница 33: ...nly a part of number e g 1234 As a result all numbers with this sequence will be authorized e g 600123456 or 601234567 b If modem connected to OSM 2007 server will be used to make connections CSD its number have to be entered on the list 7 5 3 Validity period of outgoing SMS messages User may limit time for the GSM operator to deliver information via SMS when recipient is unavailable due to out of...

Страница 34: ... 7 6 SMS NOTIFICATIONS User may define messages that in case of any event e g input state change will be sent to private phone numbers At the same time it is worth to remember about limitation in this respect 7 6 1 Phone numbers One way to limit amount of sent information by SMS is to define a list of 5 private phone numbers This list means that only telephones listed on it will receive messages s...

Страница 35: ...if this event follows To define use edition field on the right of events list Follow the procedure a Select event to edit from the list b Mark square next to phone number that SMS is to sent to c Enter message text of SMS when field is active d If the Copy the contents from first message will be marked then selection and text content will be automatically copied from the first message otherwise yo...

Страница 36: ... days number of hours the number of minutes No selection in the Send test every will disable SMS user tests 7 6 3 Status The device provides for remote enquiry about the status Edit in this field message text that is to be sent to the user as a reply to command regarding status checking Telephone numbers authorized to send enquiry about status are defined in option Restrictions Authorized SMS phon...

Страница 37: ...e cases a part of sender phone number may be an empty string which means that any phone number matches to the rule All rules are processed with given order It means that in some cases one SMS message may be forwarded to more than one recipients and or some of them may be forwarded more than once to the same recipient The second case may occur when there are at least two rules with the same recipie...

Страница 38: ...ermining action of device if outside GSM network Define time limit after which transmitter shall reconnect to network Enter time limit in field Reset after and provide this value in minutes Next define action that the device shall perform Select action by marking proper square next action description o Modem Reset o Device Reset o Turn on output 1 OUT1 o Turn on output 2 NC NO C In case of no conn...

Страница 39: ... network Enter time limit in field Reset after and provide this value in minutes Next define action that the device shall perform Select action by marking proper square next action description o Modem Reset o Device Reset o Turn on output 1 OUT1 o Turn on output 2 NC NO C In case of no connection with GPRS network the device after recognizing the situation shall wait during provided time limit and...

Страница 40: ...200 Data bits 5 6 7 8 Parity None even odd mark space Stop bits 1 2 Flow control None RTS CTS RTS CTS The selected parameters shall correspond to RS 232 port settings in device with which the transmitter is to cooperate 7 8 2 Buffer flushing Data received from connected device are stored in transmitter buffer Buffer capacity is 511 bytes Define criteria that meeting shall mean data transmission to...

Страница 41: ... data receiving via RTS if transmitter begin to send data to the device 7 8 3 4 Tests of device connection to port If the device connected to transmitter port generates periodical connection tests these tests may be under control To provide for that after this option activation enter text message and define frequency in Test presence every s option Additionally user may determine if text messages ...

Страница 42: ... time of decay that will be signalized with an adequate message sent via GPRS Note The transmitter is to simulate a telephone line access if o A PSTN line is not connected o A PSTN line is connected but has not been activated option from clause 7 9 1 1 o Options from clause 7 9 1 1 and clause 7 9 1 2 are active and voltage on terminals TIP RING decreased below 8V 7 9 1 3 Report off hook If a phone...

Страница 43: ...that during a receiver picking up a tone of dialling was actuated To enable cooperation with a transmitter it is possible to make a transmitter to generate such tone 7 9 2 First and Second phone number To provide for proper cooperation between a transmitter and a control panel in DTMF mode determination of some parameters is required The below described functions are analogous to the both telephon...

Страница 44: ...able then it will be used during transmission from the control panel 2 Disable CRC checking option may be used for ContactID and Ademco formats Some control panel generate improper messages regarding a control sum for transmitted data the device is not able to confirm collection of data and as a result the panel tries to send them again until execution of all determined trials Select this option t...

Страница 45: ...ith new firmware click Open button to locate where file is d Select file transmission mode local or remote Note Procedure of assigning firmware to a device is analogous to programming a device For procedure refer to chapter 8 Programming of the device e Click Start button to start software exchange f Loading course is displayed on special window g Close the window after completed saving From this ...

Страница 46: ...nitor provides following information AC power indication Battery power indication PSTN line indication GSM network signal level indication Bit Error Rate level measuring Inputs and outputs state monitoring Type or serial number of device Firmware and hardware revision Device time These parameters are also shown in LOG window in text style All data can be saved to file Note Outputs OUT1 and NC NO C...

Страница 47: ... both using a GPRS connection and RS232 In the second case data can be send to PC only via LX PROG cable the white one Correct RS232 port or GPRS connection must be chosen in Choose connection kind field After providing Service code and clicking Open button events data will be downloaded from PX200N memory After properly reading access to features such as the Filtering and Charts becomes possible ...

Страница 48: ...PX200N_Manual_en 1 11i7 Page 48 58 ...

Страница 49: ...h and red one shall flicker c Launch software and define device options description is in chapter 6 of this Manual Provide right PIN code for SIM card d Save settings into memory of device Saving course is displayed in special window e After saving disconnect power supply and disassembly service wire f Insert SIM card Connect module wiring pursuant to guidelines from chapter 3 Turn power supply on...

Страница 50: ... of OSM 2007 console position cursor on proper device in Devices tab b Click Config option and then select Set Configuration function to display lit of parameters c Enter server address server port and APN Click OK and system shall send to device provided parameters SMS d Wait till device addresses server in Devices tab it will be marked with green colour e Launch software and define options of de...

Страница 51: ...will be lost OUT outNr state Turn on or turn off outputs outNr specifies output number 0 for OUT1 1 for relay output state specifies requested output state 0 switched off 1 switched on Examples OUT 1 0 switches off relay output OUT 1 1 switches on relay output CMD timeout command Issues AT command to GSM modem and sends response back Optional timeout parameter defines time for modem response Time ...

Страница 52: ...n minutes time between SMS test messages sending to the server OLD Switch device operating in encoded protocol mode into operation in old PX device emulation mode RLIMIT Removes automatic temporary locks on all inputs RLIMIT inputs_mask Removes selected automatic temporary locks Parameter is decimal number made from 9 bit word A9 A2 A1 where A1 means TAMPER A2 INPUT 1 and A9 INPUT8 EXAMPLE RLIMIT ...

Страница 53: ...on TMP1 Switches on OUT1 output TMP0 Switches off OUT1 output AUX1 Switches on relay output AUX0 Switches off relay output INT_ON TMP sabotage input lock IN1_ON 1 input lock IN2_ON 2 input lock IN3_ON 3 input lock IN4_ON 4 input lock IN5_ON 5 input lock IN6_ON 6 input lock IN7_ON 7 input lock IN8_ON 8 input lock INA_ON All inputs lock with no impact on sabotage input INT_OFF TMP sabotage input unl...

Страница 54: ...reen Red Logging to GSM 10 2 GSM RANGE Flickering of a green diode indicates GSM signal 1 8 flickers Device operation mode is signalled with a green diode on during 2 seconds once the range was detected If after signalling range diode will not flash for 2 seconds the device is in SMS mode Range indication is interrupted during data transmission and after sending of data again GSM range is being in...

Страница 55: ...escription Green Red GPRS Transmission SMS Transmission 10 4 RECEIVING OF DTMF DATA Yellow diodes marked as DTMF and STATUS indicate actual condition during receiving data from a control panel LED Diode Signalling STATUS DTMF HandShake KissOff 6 digits of phone 16 digits ContactID DTMF ERR OK STATUS DTMF ERR OK STATUS DTMF ERR OK STATUS ...

Страница 56: ...ce wire Programming in CSD mode 10 6 FIRMWARE UPDATING During programming bootlader operating is indicated If error follows during updating there is bootloader in device and another programming of device is possible LED Diodes Description Green Red No program in device 1 sec Software updating Received firmware decoding 10 sec DTMF ERR OK STATUS DTMF ERR OK STATUS ...

Страница 57: ...DE Sleep mode see 7 4 5 Sleep when the battery voltage less than is indicated by alternating lighting and off LEDs OK and ERR LED diode Signalling OK green ERROR red 10 9 SYSTEM ERROR During operating errors may follow Any error is indicated by constant flashing of a red diode and mostly it means communication problem with modem or SIM card DTMF ERR OK STATUS DTMF ERR OK STATUS ...

Страница 58: ... 1 11i3 Firmware update and GPRS configurator update 28 01 2010 1 11i4 Added parameter of battery voltage at which the transmitter goes into Sleep mode 05 02 2010 1 11i5 User SMS tests reading history via GPRS battery voltage threshold for Sleep mode 15 03 2010 1 11i6 Amendment descriptions and screenshots for the outputs 18 03 2010 1 11i7 Amendment descriptions and screenshots for the outputs ...

Отзывы: