Operating instructions

W6E500-KJ05-11

Translation of the original operating instructions

For operation with variable frequency drives, install sinusoidal
filters that work on all poles (phase-phase and phase-ground)
between the drive and the motor.
During operation with variable frequency drives, an all-pole
sine filter protects the motor against high-voltage transients that
can destroy the coil insulation system, and against harmful
bearing currents.

Heating-up of the motor when using a variable frequency drive must be
checked by the customer following installation in the end device.

4.3 Connecting the cables

The device has external leads.

;

First connect the "PE" (protective earth).

Connect the cables according to your application. When doing so,
observe Chapter 4.4 Connection diagram.

Fig. 1: Recommended stripped lengths in mm

4.3.1 Motor protection

CAUTION
Voltage

The device is a built-in component and has no disconnecting
switch.
→ Connect the device to a suitable tripping unit.
→ Only connect the device to circuits that can be switched

off with an all-pole disconnection switch.

→ When working on the device, secure the system/

machine in which the device is installed so as to prevent it
from being switched back on.

NOTE
Lack of motor protection

Without motor protection, the motor can overheat and suffer
damage.
→ Connect the thermal overload protector installed in the

winding.

The motor is provided with a thermal overload protector (TOP). Always
check that the thermal overload protector (TOP) is properly connected
before start-up. Failure to connect the thermal overload protector correctly
will invalidate your warranty claim.
Externally wired thermal overload protectors must be integrated in the
control circuit of a tripping unit. The fan’s power supply is passed through
the main circuit of the tripping unit. In the event of a fault, an automatic
restart after cooling must be prevented.
The following contact ratings must not be exceeded:

U

I

AC

250 V

2.3 A

Item no. 15832-5-9970 · ENU · Change 230069 · Approved 2021-05-27 · Page 9 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W6E500-KJ05-11

Страница 1: ...zed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Страница 2: ...lace any objects on the guard grill There must be sufficient space around the fan to be able to get past the fan 1 6 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into...

Страница 3: ...ohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration tr...

Страница 4: ...duct drawing All dimensions in mm 1 Airflow direction V 2 Cable silicone 5G 0 5 mm 5x wire end ferrule Item no 15832 5 9970 ENU Change 230069 Approved 2021 05 27 Page 4 13 ebm papst Mulfingen GmbH Co...

Страница 5: ...ort struts only in X position as illustrated or rotor on bottom 2 For horizontal shaft installation position the cable exit must be at the bottom right Item no 15832 5 9970 ENU Change 230069 Approved...

Страница 6: ...ecific ratio 1 pfs 100 000 Pa Data obtained at optimum efficiency level The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weig...

Страница 7: ...A heated drip pan that reliably discharges any water emerging from the outflow side is available for the AxiCool fans ebm papst recommends the use of a drip pan in conjunction with the AxiCool heating...

Страница 8: ...the fan is installed so as to prevent it from being switched back on NOTE Water ingress into wires or cables Water ingresses at the customer cable end and can damage the device Make sure the end of t...

Страница 9: ...connect the device to circuits that can be switched off with an all pole disconnection switch When working on the device secure the system machine in which the device is installed so as to prevent it...

Страница 10: ...tion diagram L U1 blue N U2 black PE green yellow TW Thermal overload protector gray 2x Item no 15832 5 9970 ENU Change 230069 Approved 2021 05 27 Page 10 13 ebm papst Mulfingen GmbH Co KG Bachm hle 2...

Страница 11: ...o disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING...

Страница 12: ...vals to the actual level of dust exposure 5 2 Safety inspection What to check How to check How often What action Contact protection cover for intactness or damage Visual inspection At least every 6 mo...

Страница 13: ...xternal rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...

Отзывы: