ebm-papst W6E500-KJ05-11 Скачать руководство пользователя страница 7

Operating instructions

W6E500-KJ05-11

Translation of the original operating instructions

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.5 Mounting data

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

3.6 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+70 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

3.7 Accessories

3.7.1 AxiCool heating tape

A heating tape that can be integrated into the fan housing is available for
the AxiCool fans. To prevent ice formation, ebm-papst recommends the
use of a heating tape for all applications below 0°C. The heating tape
designed for the AxiCool fan housing is available from ebm-papst under
the following item number.

Size

Item no.

500 mm

00500-2-7680

During assembly, comply with the installation instructions included with
each ebm-papst heating tape. ebm-papst assumes no liability when
heating tapes from other manufacturers are used. Note the maximum
permitted temperature of +80 ± 5 °C for the heating tape to prevent
damage to the fan housing.

NOTE
The heating tape has only basic insulation.

→ The heating tape may only be used with a closed fan

housing cover to prevent heat losses and contact with live
parts.

3.7.2 AxiCool drip pan

A heated drip pan that reliably discharges any water emerging from the
outflow side is available for the AxiCool fans. ebm-papst recommends
the use of a drip pan in conjunction with the AxiCool heating tape. The
drip pan designed for the AxiCool fan housing is available from ebm-
papst under the following item number.

Size

Item no.

500 mm

41200-1-4050

Installation instructions are included with every ebm-papst drip pan and
must be heeded on assembly.

3.7.3 AxiCool terminal box

A terminal box kit for attachment to the fan housing is available for
AxiCool fans. This terminal box kit provides an ideal means of
connecting the electrical connections of the motor, heating tape and drip
pan. The terminal box kit to suit the AxiCool fan housing and motor is
available from ebm-papst under the following item number.

Motor/connection

Item no.

M__110, M__138 / AC

50015-1-7612

Installation instructions are included with every ebm-papst terminal box
kit and must be heeded on assembly.

4. CONNECTION AND STARTUP

4.1 Mechanical connection

CAUTION
Cutting and crushing hazard when removing device
from packaging

Blades can bend
→ Carefully remove the device from its packaging, by the fan

housing. Strictly avoid shocks.

→ Wear safety shoes and cut-resistant safety gloves.

CAUTION
Heavy load when unpacking device

Risk of physical injury, such as back injuries.
→ Two people should work together to remove the device from

its packaging.

CAUTION
The blades of the impeller could be damaged.

→ Carefully set down the fan on a soft surface. Make sure the

blades are not subjected to load.

→ Following installation, make sure the impeller moves

easily and that the blades of the impeller are not deformed or
bent and do not catch at any point.

NOTE
Damage to the device from vibration

Bearing damage, shorter service life
→ The fan must not be subjected to force or excessive vibration

from sections of the installation.

→ If the fan is connected to air ducts, the connection should

be isolated from vibration, e.g. using compensators or similar
elements.

→ Ensure stress-free attachment of the fan to the

substructure.

Item no. 15832-5-9970 · ENU · Change 230069 · Approved 2021-05-27 · Page 7 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W6E500-KJ05-11

Страница 1: ...zed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Страница 2: ...lace any objects on the guard grill There must be sufficient space around the fan to be able to get past the fan 1 6 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into...

Страница 3: ...ohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration tr...

Страница 4: ...duct drawing All dimensions in mm 1 Airflow direction V 2 Cable silicone 5G 0 5 mm 5x wire end ferrule Item no 15832 5 9970 ENU Change 230069 Approved 2021 05 27 Page 4 13 ebm papst Mulfingen GmbH Co...

Страница 5: ...ort struts only in X position as illustrated or rotor on bottom 2 For horizontal shaft installation position the cable exit must be at the bottom right Item no 15832 5 9970 ENU Change 230069 Approved...

Страница 6: ...ecific ratio 1 pfs 100 000 Pa Data obtained at optimum efficiency level The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weig...

Страница 7: ...A heated drip pan that reliably discharges any water emerging from the outflow side is available for the AxiCool fans ebm papst recommends the use of a drip pan in conjunction with the AxiCool heating...

Страница 8: ...the fan is installed so as to prevent it from being switched back on NOTE Water ingress into wires or cables Water ingresses at the customer cable end and can damage the device Make sure the end of t...

Страница 9: ...connect the device to circuits that can be switched off with an all pole disconnection switch When working on the device secure the system machine in which the device is installed so as to prevent it...

Страница 10: ...tion diagram L U1 blue N U2 black PE green yellow TW Thermal overload protector gray 2x Item no 15832 5 9970 ENU Change 230069 Approved 2021 05 27 Page 10 13 ebm papst Mulfingen GmbH Co KG Bachm hle 2...

Страница 11: ...o disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING...

Страница 12: ...vals to the actual level of dust exposure 5 2 Safety inspection What to check How to check How often What action Contact protection cover for intactness or damage Visual inspection At least every 6 mo...

Страница 13: ...xternal rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...

Отзывы: