ebm-papst W6E500-KJ05-11 Скачать руководство пользователя страница 6

Operating instructions

W6E500-KJ05-11

Translation of the original operating instructions

3.2 Nominal data

Motor

M6E110-EF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

ml

ml

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

865

900

Power consumption / W

210

290

Current draw / A

0.95

1.3

Capacitor / µF

5

5

Capacitor voltage / VDB

400

400

Capacitor standard

S0 (CE)

S0 (CE)

Max. back pressure / Pa

60

57

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

40

40

Starting current / A

1.7

1.51

Max. safe operating
speed (rpm) /
min

-1

1920
@ 55 °C

1920
@ 55 °C

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

33.4

29.5

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

43.9

40

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen

08 Type

W6E500-KJ05-11

09 Power consumption P

e

/ kW

0.21

09 Air flow q

v

/ m³/h

3750

09 Pressure increase total p

fs

/

Pa

70

10 Speed (rpm) n / min

-1

865

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller

combination in a standardized measurement setup.

3.4 Technical description

Weight

14.3 kg

Size

500 mm

Motor size

110

Rotor surface

Painted black

Blade material

Press-fitted sheet steel blank, sprayed
with PP plastic

Fan housing material

PP plastic

Material guide vanes

PP plastic

Guard grille material

Steel, coated with black plastic (RAL
9005)

Number of blades

5

Airflow direction

V

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP54

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

H2

Ambient temperature
note

If there is a risk of ice formation, the fan
is only to be operated with a heating tape
in the fan housing. Further information
can be obtained from ebm-papst. As fan
only suitable for use with industrial
evaporators

Installation position

See fitting instructions

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing with low-temperature lubricant

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Thermal overload protector (TOP) with
basic insulation

Protection class

I (with customer connection of protective
earth)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Conformity with
standards

EN 60034-1 (2010); CE

Approval

VDE; EAC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Item no. 15832-5-9970 · ENU · Change 230069 · Approved 2021-05-27 · Page 6 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание W6E500-KJ05-11

Страница 1: ...zed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Страница 2: ...lace any objects on the guard grill There must be sufficient space around the fan to be able to get past the fan 1 6 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into...

Страница 3: ...ohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration tr...

Страница 4: ...duct drawing All dimensions in mm 1 Airflow direction V 2 Cable silicone 5G 0 5 mm 5x wire end ferrule Item no 15832 5 9970 ENU Change 230069 Approved 2021 05 27 Page 4 13 ebm papst Mulfingen GmbH Co...

Страница 5: ...ort struts only in X position as illustrated or rotor on bottom 2 For horizontal shaft installation position the cable exit must be at the bottom right Item no 15832 5 9970 ENU Change 230069 Approved...

Страница 6: ...ecific ratio 1 pfs 100 000 Pa Data obtained at optimum efficiency level The ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weig...

Страница 7: ...A heated drip pan that reliably discharges any water emerging from the outflow side is available for the AxiCool fans ebm papst recommends the use of a drip pan in conjunction with the AxiCool heating...

Страница 8: ...the fan is installed so as to prevent it from being switched back on NOTE Water ingress into wires or cables Water ingresses at the customer cable end and can damage the device Make sure the end of t...

Страница 9: ...connect the device to circuits that can be switched off with an all pole disconnection switch When working on the device secure the system machine in which the device is installed so as to prevent it...

Страница 10: ...tion diagram L U1 blue N U2 black PE green yellow TW Thermal overload protector gray 2x Item no 15832 5 9970 ENU Change 230069 Approved 2021 05 27 Page 10 13 ebm papst Mulfingen GmbH Co KG Bachm hle 2...

Страница 11: ...o disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING...

Страница 12: ...vals to the actual level of dust exposure 5 2 Safety inspection What to check How to check How often What action Contact protection cover for intactness or damage Visual inspection At least every 6 mo...

Страница 13: ...xternal rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...

Отзывы: