Part Number
Operating Instructions
Item no. LS-105.
Revision 003
Release 30/06/2017
Page 3 of 12
ebm-papst A&NZ Pty Ltd
10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464
ABN 33 115 927 556
NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246
[email protected] · www.ebmpapst.com.au
W3G500GN3307-LA1
1.11
Storage
Store the device, partially or fully assembled, in a dry and
weatherproof manner in the original packing in a clean
environment.
Protect the device from environmental impacts and dirt
until the final installation.
We recommend storing the device for no longer than one
year in order to guarantee trouble-free operation and
longest possible service life.
Even devices explicitly intended for outdoor use are to be
stored as described prior to being commissioned.
Maintain the storage temperature; see chapter 3.5
Transport and storage conditions .
Make sure that all screwed cable glands are fitted with
dummy plugs.
2.
INTENDED USE
The device is exclusively designed as a built-in device for
moving air according to its technical data.
Any other or secondary use is deemed improper and constitutes
a misuse of the device.
Installations on the customer's side must meet the mechanical,
thermal and service life-related stresses that can occur.
Intended use also includes:
Use the device in power systems with earthed neutral
(TN/TT power systems only).
Using the device only in stationary systems.
Performing all maintenance work.
Moving air with a density of 1.2 kg/m
3
.
Using the device range within the permitted ambient
temperature range, see chapter 3.5 Transport and
storage conditions and chapter 3.2 Nominal data.
Operate the device with all protective features.
Following the operating instructions.
Improper use
Using the device in the following ways is particularly prohibited
and may cause hazards:
Operating the device in an imbalance state, e.g. due
to dirt deposits or ice formation.
Operating in medical equipment with a life-sustaining
or lifesaving function.
Operating with external vibrations.
Moving solids content in flow medium.
Painting the device.
Connections (e.g. screws) coming loose during
operation.
Opening the terminal box during operation.
Moving air that contains abrasive particles.
Moving highly corrosive air, e.g. salt spray.
Exceptions are devices that are designed for salt
spray and protected accordingly.
Moving air with dust content, e.g. suctioning off saw
dust.
Operating the device close to flammable materials or
components.
Operating the device in an explosive atmosphere.
Using the device as a safety component or for taking
on safety-related functions.
Operation with completely or partially disassembled
or modified protective features.
In addition, all applications not listed among the
intended uses.