6. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES

Do not perform any repairs on your device. Return the device to ebm-

papst for repair or replacement.

WARNING

Terminals and connections have voltage even with a

unit that is shut off

Electric shock
→ Wait five minutes after disconnecting the voltage at all poles

before opening the device.

CAUTION

If control voltage is applied or a speed setpoint is stored,

the motor automatically restarts, e.g. after a power failure.

Danger of injury
→ Keep out of the danger zone of the device.
→ When working on the device, switch off the mains

supply voltage and secure the latter from being switched on

again.

→ Wait until the device stops.
→ After working on the device, remove any used tools or

other objects from the device.

If the device remains out of use for over four months, we

recommend switching the device on for at least three hours at

full speed to allow any condensate to evaporate and to move

the bearings.

Malfunction/error

Possible cause

Possible remedy

Impeller running

roughly

Imbalance in rotating

parts

Clean the device; if

imbalance is still

evident after

cleaning, replace the

device.

If you have

attached any weight

clips during cleaning,

make sure to

remove them

afterwards.

Motor does not turn

Mechanical blockage Switch off, de-

energise, and

remove mechanical

blockage.

Mains supply

voltage faulty

Check mains supply

voltage,

restore power

supply.

Important! The error

message resets

automatically.

The device starts

up again

automatically without

advance warning.

Faulty connection

De-energise, correct

connection, see

connection diagram.

Motor winding broken Replace device

Insufficient cooling

Improve cooling. Let

the device cool

down.

To reset the error

message, switch off

the mains supply

voltage for a min. of

25 s and switch it on

again.

Alternatively, reset

the error message

by applying a control

signal of <0.5 V to

DIN1 or by short

circuiting Din1 to

GND.

Ambient temperature

too high

Reduce the ambient

temperature. Let the

device cool down.

To reset the error

message, switch off

the mains supply

voltage for a min. of

25 s and switch it on

again.

Alternatively, reset

the error message

by applying a control

signal of <0.5 V to

DIN1 or by short

circuiting Din1 to

GND.

Unacceptable

operating point (e.g.

counterpressure is

too high)

Correct the operating

point. Let the device

cool down.

To reset the error

message, switch off

the mains supply

voltage for a min. of

25 s and switch it on

again.

Alternatively, reset

the error message

by applying a control

signal of <0.5 V to

DIN1 or by short

circuiting Din1 to

GND.

If you have any other problems, contact ebm-papst.

Item no. 50647-5-9970 · ENG · Revision 82549 · Release 2014-05-08 · Page 11 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание K3G400-AQ23-01

Страница 1: ......

Страница 2: ...to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is...

Страница 3: ...on the system machine wait until all parts have come to a standstill DANGER Flying parts Missing safety devices may cause balancing weights or broken fan blades to be ejected at high speeds causing bo...

Страница 4: ...ce in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Operation in medical equipment with a life sustain...

Страница 5: ...ameter min 4 mm max 10 mm tightening torque 4 0 6 Nm 3 Tightening torque 3 5 0 5 Nm 4 Mounting position shaft horizontal install the support struts only vertically as shown in the view or rotor on bot...

Страница 6: ...fer to product drawing Condensate discharge holes Rotor side Operation mode S1 Motor bearing Ball bearing Technical features Output 10 VDC max 10 mA Output 20 VDC max 50 mA Output for slave 0 10 V Inp...

Страница 7: ...er be installed Install the undamaged device according to your application 4 2 Connecting the electrical system DANGER Electric voltage on the device Electric shock Always install a protective earth f...

Страница 8: ...AC 16 A 15 A C16A 1 5 16 3 PE AC 380 480 VAC 20 A 20 A C20A 2 5 14 3 PE AC 380 480 VAC 25 A 25 A C25A 4 0 12 3 PE AC 380 480 VAC 32 A 30 A C32A 6 0 10 AWG American Wire Gauge 4 2 3 Idle current Becaus...

Страница 9: ...e corresponding terminals Use a screwdriver to do so During the connection work ensure that no cables splice off Fig 2 Connecting the wires to terminals Seal the terminal box 4 3 3 Cable routing No wa...

Страница 10: ...n pin or applied voltage 5 50 VDC disabling bridge to GND or applied voltage 1 VDC reset function triggers software reset after a level change to 1 VDC SELV KL 3 8 Din2 Digital input 2 parameter set s...

Страница 11: ...fan for foreign objects and remove any that are found Apply the nominal voltage to the voltage supply Start the device by changing the input signal 4 8 Switching off the device Switching off the devi...

Страница 12: ...Switch off de energise and remove mechanical blockage Mains supply voltage faulty Check mains supply voltage restore power supply Important The error message resets automatically The device starts up...

Страница 13: ...nst accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual...

Отзывы: