Operating instructions

G3G200-GN18-01

Translation of the original operating instructions

3.6 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

3.7 Electromagnetic compatibility

EMC immunity to
interference

According to EN 61000-6-2 (industrial
environment)

EMC circuit feedback

According to EN 61000-3-2/3

EMC interference
emission

According to EN 61000-6-4 (industrial
environment)

4. CONNECTION AND STARTUP

4.1 Mechanical connection

DANGER
Gas leaking from poorly sealed housing

Risk of fatal injury
→ Prior to startup, verify whether the gas blower's housing is

pressure-tight.
When doing so, seal off the intake and outlet openings as
well as the shaft opening.

→ In addition, verify that no rotating parts scrape against

stationary parts.

DANGER
Leaks may occur.

Due to its design, the gas blower is not tightly sealed, e.g. at
the shaft opening. This may result in leaks during operation.
Deflagrations may also cause long-term damage or deformation
of the housing, which can result in leaks. An air/gas mixture
may accumulate outside of the gas blower. The blower can
explode. Severe injuries can result.
→ Check which hazards arise from installing, operating,

servicing or disposing of the gas blower in conjunction with
your device.
Avoid any such hazards.
Carry out all necessary measures.

CAUTION
Cutting and crushing hazard when removing blower
from packaging

→ Carefully remove the blower from its packaging, touching

only the housing. Strictly avoid shocks.

→ Wear safety shoes and cut-resistant safety gloves.

NOTE
Damage to the device from vibration

Bearing damage, shorter service life
→ The fan must not be subjected to force or excessive vibration

from sections of the installation. #If the fan is connected to air
ducts, the connection should be isolated from vibration, e.g.
using compensators or similar elements. #Ensure stress-free
attachment of the fan to the substructure.

;

Check the device for transport damage. Damaged devices are not to
be installed.

;

Install the undamaged device in accordance with your application.

CAUTION
Possible damage to the device

If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of

installation until all fastening screws have been tightened.

4.2 Electrical connection

DANGER
Voltage on the device

Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.

DANGER
Faulty insulation

Risk of fatal injury from electric shock
→ Use only cables that meet the specified installation

regulations for voltage, current, insulation material, capacity,
etc.

→ Route cables so that they cannot be touched by any

rotating parts.

DANGER
Electrical charge (>50 µC) between phase conductor and
protective earth connection after switching off supply
with multiple devices connected in parallel.

Electric shock, risk of injury
→ Ensure sufficient protection against accidental contact.

Before working on the electrical hookup, short the supply
and PE connections.

CAUTION
Voltage

The device is a built-in component and has no disconnecting
switch.
→ Only connect the device to circuits that can be switched off

with an all-pole disconnection switch.

→ When working on the device, secure the system/

machine in which the device is installed so as to prevent it
from being switched back on.

NOTE
Water ingress into wires or cables

Water ingress at the customer end of the cable can damage the
device.
→ Make sure the end of the cable is connected in a dry

environment.

The control voltage circuit is not electrically isolated. Only
connect the device to circuits that can be switched off with an
all-pole disconnection switch.

Item no. 50131-5-9970 · ENU · Change 72552 · Approved 2012-08-17 · Page 6 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Содержание G3G200-GN18-01

Страница 1: ...qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic s...

Страница 2: ...is EMC compliant 1 7 Mechanical movement DANGER Danger of injury from open blower Escaping gas When the blower is open you come into contact with rotating and electrically live parts Escaping gas can...

Страница 3: ...storage conditions and Chapter 3 2 Nominal data Using the device only in stationary systems Installing the device in an integrated system for conveying air Commissioning the built in component only a...

Страница 4: ...6 1 socket tyco no 926884 1 1 1 L 1 2 N 1 3 PE 2 5 pole header fits mating connector not included in scope of delivery Molex no 39 01 4050 socket Molex no 39 00 0059 2 1 2 2 Speed monitoring 2 3 0 10...

Страница 5: ...rent from the measurement category are detailed in the CE declaration Specific ratio 1 pfs 100 000 Pa Data obtained at optimum efficiency level The ErP data is determined using a motor impeller combin...

Страница 6: ...should be isolated from vibration e g using compensators or similar elements Ensure stress free attachment of the fan to the substructure Check the device for transport damage Damaged devices are not...

Страница 7: ...wed As with variable frequency drives residual current devices cannot provide personal safety while operating the device When the device s power supply is switched on pulsed charging currents from the...

Страница 8: ...B external voltage 16 45 VDC maximum ripple 3 5 SELV ST2 2 Tach Speed monitoring 3 pulses per revolution SELV ST2 3 0 10 V Control input 0 10 V impedance 100k SELV ST2 4 PWM Control input PWM 1 6 kHz...

Страница 9: ...via the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connec...

Страница 10: ...tion At least every 6 months Replace cables Condensation drainage holes for clogging where necessary Visual inspection At least every 6 months Open holes Abnormal bearing noise acoustic At least every...

Страница 11: ...wires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for...