Operating instructions
G3G200-GN18-01
Translation of the original operating instructions
You can control the blower either via the 0-10 VDC input or the
PWM input. Attention: The inputs cannot be used simultaneously.
3.2 Nominal data
Motor
M3G084-DF
Phase
1~
Nominal voltage / VAC
230
Nominal voltage
range / VAC
208 .. 240
Frequency / Hz
50/60
Method of obtaining
data
ml
Speed (rpm) / min
-1
5700
Power consumption / W
750
Current draw / A
3.6
@ 208 V
Min. ambient
temperature / °C
-20
Max. ambient
temperature / °C
60
Min. temp. of flow
medium / °C
0
Max. temp. of flow
medium / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to Commission Regulation (EU) 327/
2011
Actual
Req. 2015
01 Overall efficiency η
es
/ %
54.3
48.2
02 Measurement category
A
03 Efficiency category
Static
04 Efficiency grade N
67.1
61
05 Variable speed drive
Yes
06 Year of manufacture
The year of manufacture is specified on the
product's rating label.
07 Manufacturer
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen
08 Type
G3G200-GN18-01
09 Power consumption P
ed
/ kW
0.6
09 Air flow q
v
/ m³/h
485
09 Pressure increase total p
sf
/
Pa
2219
10 Speed (rpm) n / min
-1
5710
11 Specific ratio
*
1.02
12 Recycling/disposal
Information on recycling and disposal is
provided in the operating instructions.
13 Maintenance
Information on installation, operation and
maintenance is provided in the operating
instructions.
14 Additional components
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
3.4 Technical description
Weight
9.2 kg
Fan size
200 mm
Rotor surface
Painted black
Cover material
Polyflam RPP 374-ND CS1 (UL 97-V0)
Impeller material
Sheet aluminum
Housing material
Die-cast aluminum
Number of blades
7
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP20
Insulation class
"B"
Installation position
Any
Condensation
drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Thermal overload protection for
electronics/motor
- PFC, active
- Motor current limitation
- Undervoltage / phase failure detection
- PWM control input
- Control input 0-10 V
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Electrical hookup
With plug
Motor protection
Locked-rotor protection
Protection class
I (with customer connection of protective
earth)
Approval
UL 507; CSA C22.2 No. 113; EAC;
CCC
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.5 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
Item no. 50131-5-9970 · ENU · Change 72552 · Approved 2012-08-17 · Page 5 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com