![ebm-papst G1G170-AB05-81 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ebm-papst/g1g170-ab05-81/g1g170-ab05-81_operating-instructions-manual_4210071006.webp)
Operating instructions
G1G170-AB05-81
Translation of the original operating instructions
You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.
3.2 Nominal data
Motor
M1G074-CF
Phase
1~
Nominal voltage in VAC
115
Frequency in Hz
50/60
Type of data definition
fa
Speed in min
-1
5730
Power input in W
345
Current draw in A
4.0
Min. ambient
temperature in °C
- 25
Max. ambient
temperature in °C
+ 55
Min. temp. of flow
medium in °C
-25
Max. temp. of flow
medium in °C
+80
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical description
Mass
4.4 kg
Size
170 mm
Surface of rotor
Coated in black
Material of protective
cover
Polyflam RPP 374-ND CS1 (UL 97-V0)
Material of impeller
Aluminium sheet
Housing material
Die-cast aluminium
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Cooling bore / aperture
Rotor-side
Operation mode
S1
Premix
If gas is premixed in the blower, a
special blower must be used. Contact us
for details.
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 10 mA
- Tach output
- Motor current limit
- Control input 0-10 VDC / PWM
- Over-temperature protected motor
Leakage current
<= 3.5 mA
Electrical leads
With plug
Motor protection
Thermal overload protector (TOP) wired
internally
Approval
UL 507; CSA C22.2 Nr.113
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Graphic rendition of products
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
3.6 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2
EMC interference
emission
Acc. to EN 61000-6-3 (household
environment)
Item no.: 51198-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 6 / 12