Operating instructions
G1G170-AB05-81
Translation of the original operating instructions
4.4 Connection diagram
No.
Pin
Signal
Function / assignment
ST1
1, 2, 3 L, N, PE
Power supply 115 VAC, 50-60 Hz, phase, neutral, protective earth
ST2
1
10V/ max.
10mA
Voltage output 10 VAC (+/-3%), max. 10 mA, power supply for ext. devices (e.g. potentiometer), SELV
ST2
2
DUE
Speed monitoring, 3 pulses per revolution, SELV
ST2
3
0-10V
Control input 0-10 V, impedance 100k, SELV
ST2
4
PWM
Control input PWM, 1-6 kHz, SELV
ST2
5
GND
GND - Connection for control interface, SELV
Item no.: 51198-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 9 / 12