Operating instructions
A3G910-AO84-21
Translation of the original operating instructions
Mounting of
protective
earth connection
Visual inspection At least every
6 months
Fasten
Check the
insulation of
the wires for
damage
Visual inspection At least every
6 months
Replace wires
Condensate
discharge
holes for
clogging, as
necessary
Visual inspection At least every
6 months
Open bore holes
Weld seams
for crack
formation
Visual inspection At least every
6 months
Replace unit
Check the ball
bearings to
ensure they
are quiet, can
move easily
and are free of
play
Manual check
by turning the
rotor in shut-off
state
At least every
6 months
Replace
device in case
of noise,
difficulty of
movement or
clearance of
the bearings
Item no.: 50437-5-9970 · Revision: 73097 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 11 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com