background image

 

 

 

REQU+ / REQU R+ REMOTE CONTROL USER INSTRUCTIONS

 

COMMANDS LIST

 

Surveillance Function 

 

Automatic Mode 

Speed Selection 

Humidity Limit selection 

Air Flow Direction 

Intake Air Function 

Extract Air Function 

COMMANDS INSTRUCTIONS 
 
S – Surveillance Function (sleep mode) 
Pressing the button “SURVEILLANCE” the product remains in sleep mode with the damper closed, but keeps the 
sensors activated. In case some environment parameters like humidity or CO2 exceed the set value, the product 
automatically runs in extraction mode at the maximum speed until reset values, then it returns in sleep mode. This 
function is very useful in case of long absence.  
 
Response: 

Light pulse on activation of the modality 

Red 

Light pulse modality activated (every 1 min.)  

White/Red 

Light pulse steady, value over set 

Red 

 
A – Automatic mode 
By using the automatic mode the product runs 70 seconds in extraction and 70 seconds intake at the medium 
speed. Pressing the button “AUTO” the product performs routing check of the active sensors (night function, 
humidistat and CO2 if present), in case values are over the set parameters, the product extracts air from the 
environment at the maximum speed until restoring the threshold value. Product is equipped with twilight sensor 
(night function) . On the decrease of the intensity of the light, the product reduces the speed at the minimum to 
lower the noise generated by the air. 
 
Response: 

Light pulse on activation of the modality 

White/Red 

Light pulse modality activated (every 1 min.)  

None 

Light pulse steady, value over set 

Red 

 
 
 
 

V5 

V4 

V3 

V2 

V1 

F1 

H3 

H2 

H1 

F2 