End Suction Centrifugal
GS Series
Fault
Causes
Measures to be taken
-
Leakage in the delivery pipe.
-
Check and repair.
-
Impeller worn.
-
Check the impeller.
-
Significant head losses in the
system.
-
Review the project.
-
Liquid temperature very high. The
liquid is volatile.
-
Review the project.
-
Cavitation.
-
Seek expert advice.
-
The pump has not been primed.
-
Prime the pump correctly.
-
Air entering the system.
-
Check and repair the suction
pipe and shaft seal.
-
Air bubbles in the suction pipes.
-
Vent the pipes.
-
The suction head is too high for
the pump.
-
Review the project.
-
The voltage is low or the
imbalance between the phases is
high.
-
Check the power supply.
-
The flow rate is too high or the
head is too low.
-
Partially shut off the delivery valve.
-
Foreign bodies inside the pump.
-
Remove foreign bodies.
-
The mechanical seal was not
fitted correctly.
-
Fit it correctly.
-
Bearings damaged.
-
Replace the bearings.
-
Friction in the rotation areas. The
shaft is bent.
-
Repair in specialist workshop.
-
The direction of rotation is not
correct.
-
Check and correct the
connection.
-
The density and/or viscosity level
of the liquid is high.
-
Review the project.
-
Bearings damaged.
-
Replace the bearings.
-
In operation for a long time with
the valve closed or half-closed.
-
Avoid such a situation; close the
valve or stop the pump.
The bearings are
overheating.
Power surge
Water comes out initially
and then stops abruptly.
Low flow rate continued