P.33
PM10U
EBARA
CORPORATION
B. Driving by MAIN POWER Switch ON/OFF
START
1) Supply power to the pump.
2) Turn on the MAIN POWER switch on the pump. At the time, the pump will be started.
(The POWER Lamp, RUN Lamp on the operation panel will come on.)
3) Make sure that abnormality (unusual noise and/or vibration) is not found after the pump starts.
STOP
1) When the MAIN POWER switch (CP) is turned off, the pump will be stopped.
CONFIRMATION
Pump starts operation as soon as power is supplied if pump run command is present. Take
safety precautions and make sure that the pump inlet and outlet port are plumbed properly
before supplying power.
Pump stops in emergency off state if STOP/RESET switch on the controller is pressed during
pump operation with driving connector under direct power input. To restart the pump, turn
power off (wait until LED light goes off) then turn it back on.
6.2.2 Operation by operation-panel.
<
Please confirm the driving connector is not placed to I/O connector (CN2) >
START
1) Supply power to the pump.
Turn on the MAIN POWER switch on the pump.
(The POWER, LOCAL/REMOTE lamp on the
operation panel will come on.)
2) Press the RUN switch on the operation panel.
At the time the pump will be started.
(The RUN Lamp, on the operation panel will
come on.)
3) Make sure that abnormality (unusual noise and/or vibration) is not found after the pump starts.
STOP
1) Press the STOP/RESET switch on the operation panel, the pump will be stopped.
(The RUN Lamp on the operation panel will go out.)
STOP/RESET Switch
RUN Switch
LOCAL/REMOTE Lamp
I/O Connector
CN2
POWER Lamp
RUN Lamp