P.25
PM10U
EBARA
CORPORATION
A. How to connect wires; Single phase 100V type. [EV-A03-1]
For pin connections of the power connector, refer to Fig.4.3, Table 4.3, and Table 4.4.
Table 4.3 CN1 Receptacle Pin Assign
Pin No.
Phase
X
L : Load
Y
N : Neutral
(Ground side)
G Grounding
Fig.4.3 CN1 Pump-side Receptacle
Table 4.4 CN1 Receptacle Specification
Receptacle model
NET-243RM
Connector maker
Nanaboshi Electric Mfg. Co.,Ltd.
Applicable plug
(Note 1)
NET-243PF
Applicable wire size
AWG #12 (3.5mm
2
)
Note 1) Applicable plug is standard accessory
Note 2) Do not use cord reel for power supply, as it may cause the case where pump dose not
start due to voltage drop.
B. How to connect wires; Single phase and three phase 200Vtype. [EV-A03-2,3]
For pin connections of the power connector, refer to Fig.4.4, Table 4.5, and Table 4.6.
Table 4.5 CN1 Receptacle Pin Assign
Phase
Single phase 200V
Three phase 200V
Pin
No.
EV-A03-2 EV-A03-3
X
L : Load
R
Y
N : Neutral
(Ground side)
S
Z (Not
connected)
T
G Grounding
Fig.4.4 CN1 Pump-side Receptacle
Table 4.6 CN1 Receptacle Specification
Receptacle model
NET-244RM
Connector maker
Nanaboshi Electric Mfg. Co.,Ltd.
Applicable plug
(Note)
NET-244PF
Applicable wire size
AWG #14 (2.0mm
2
)
Note) Applicable plug is standard accessory
X
Y
G
X
Y
Z
G