CD100 OWNERS MANUAL 

Drawing No.  :-  TPC112 
Issue :- 

Date :- 

20/06/03

 

TROUBLESHOOTING 

 
 
 

S

YMPTOM

 

C

AUSE

 

R

EMEDY

 

 

Little or no airflow 

1.  Loose fan on shaft 
2.  Fan motor burnt out 
3.  Dirty refrigeration coils 

4.

 

Loose electrical wiring 

5.

 

Fuse blown 

1. Tighten fan 
2.  Replace the fan motor 
3. See 

Routine Maintenance

  Section 

4.  Check the wiring diagram to find 
  fault and repair 

5.  Replace the fuse or reset the circuit   

breaker 

Little or no water extraction 

1.  Insufficient air flow 
2. Compressor fault 
3.  Loss of refrigerant gas 

1.  Check all of the above 
2.  Contact the Factory Service Center 
3.  Contact the Factory Service Center 

Little or no defrost when 
required 

1.  Faulty Timer 
2.  Faulty bypass timer 

1.  Contact the Factory Service Center 
2.  Contact the Factory Service Center 

Unit vibrates excessively 

1.  Loose compressor mounts 
2.  Damaged fan 

1.  Tighten nuts on compressor mounts 
2.  Replace with a new fan 

Water flooding inside 
machine 

1.  Faulty water pump 
2.  Sticking float switch 
3.  Drain tray blocked 

1.  Replace water pump 
2.  Remove obstruction 
3.  Remove obstruction 

 
 
 
 
 
 

 
 
 
 

 
 

Ebac Industrial Products 

704 Middle Ground Boulevard 

Newport News 

VA 23606 

Telephone (757) 873-6800   FAX  (757) 873-3632 

Website: 

www.ebacusa.com

 

Содержание CD100

Страница 1: ...ER S MANUAL Ebac Commercial Ltd St Helens Trading Estate Bishop Auckland Co Durham DL14 9AD Telephone 01388 664400 Fax 01388 662590 Website www ebacuk com Ebac Industrial Products 704 Middle Ground Bo...

Страница 2: ...ure which is collected and led away The cool air then passes the hot condenser where it is reheated With the addition of other radiated heat the air is discharged into the room at a higher temperature...

Страница 3: ...S MODEL CD100 HEIGHT 400mm WIDTH 900mm DEPTH 500mm WEIGHT 50 Kg AIRFLOW 510 M3 hr POWER SUPPLY UK 220V 240V 1 ph 50Hz 60Hz USA 110V 120V 1 ph 50Hz 60Hz POWER 1 2kW max FINISH Vinyl coated steel REFRIG...

Страница 4: ...in anyway WIRING Connect the power mains cable to a 13 Amp power supply As follows Brown Live Blue Neutral Green Yellow Earth ground DRAINAGE Connect a 15mm inside diameter hose to the water outlet pi...

Страница 5: ...ning for 20 minutes the coils located above the drain tray will be evenly coated in frost If the ambient temperature is above 25 C the coils will be covered in water 4 After the machine has been runni...

Страница 6: ...ear to be functioning correctly then refer to the repairs section Warnings Due to the high pressures within the refrigeration circuit under no circumstances must direct heat be applied to the evaporat...

Страница 7: ...he coil approx 6 to avoid damaging the fins Alternatively vacuum clean the coils WARNING DO NOT STEAM CLEAN REFRIGERATION COILS 2 Check that the fan is firmly secured to the motor shaft and that the f...

Страница 8: ...e of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak ca...

Страница 9: ...efrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty Timer 2 Faulty bypass timer 1 Contact the...

Отзывы: