background image

 

 

 

BD-150 OWNERS MANUAL 

                                                                             Page 2 of 12 

Drawing No.  :-  TPC161 
Issue :- 

Date :- 

23/06/03

 

 

INTRODUCTION 

 
 
 

Designed for a wide range of applications, the BD-150 dehumidifier is a super high capacity 
industrial unit which provides fast and efficient drying. 
 
 
The BD-150 has a number of special features: 
 
 

 

Super high efficiency rotary compressor 

 

Temperature-sensitive microprocessor controlled defrost system 

 

Exterior epoxy powder-coated finish 

 

Rugged trolley for portability 

 

Extra long power cord 

 
 
 
The fan draws the moist air through the inlet grille on the back of the unit, then through the cold 
evaporator coil, which cools the air below its dew point.  Moisture forms on the evaporator coil 
and is collected in the condensate tray, which is equipped with a permanent drain.  The cooled 
air then passes through the hot condenser coil where it is reheated using the same energy 
removed during the cooling phase, plus the additional heat generated by the compressor.  The air 
is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower 
absolute humidity than that which entered.  Continuous circulation of air through the 
dehumidifier gradually reduces the relative humidity within the area. 
 
 
The BD-150 dehumidifier is a rugged, reliable drying unit designed to operate effectively over a 
broad range of temperature and humidity conditions.   
 
 
The unit incorporates a welded and galvanized steel chassis and is finished in an epoxy coating 
for resilience to damage caused by rough handling. 

 

 
 
 
 
 
 
 
 

Содержание BD-150

Страница 1: ...BD 150 OWNERS MANUAL Page 1 of 12 Drawing No TPC161 Issue 2 Date 23 06 03 EBAC MODEL BD 150 1024500 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Страница 2: ...s on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same...

Страница 3: ...Drawing No TPC161 Issue 2 Date 23 06 03 SPECIFICATIONS MODEL BD 150 HEIGHT 36 WIDTH 24 DEPTH 25 WEIGHT 165 lb AIRFLOW 1114 CFM POWER SUPPLY 115V 60Hz 1 ph FINISH Powder coated Epoxy OPERATING RANGE 4...

Страница 4: ...e B Press the start button DO NOT hold in this button for more than 1 second The unit will run C Check that air is being delivered through the front outlet grille and the compressor is running D After...

Страница 5: ...vely vacuum clean the coils WARNING DO NOT STEAM CLEAN REFRIGERATION COILS 2 Check that the fan is firmly secured to the motor shaft and that the fan rotates freely The fan motor is sealed for life an...

Страница 6: ...he side of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may l...

Страница 7: ...3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1...

Страница 8: ...020727 1 5 Evaporator Coil 3020732 1 6 Filter Dryer 3020904 1 7 Fan Motor Assembly 3035774 1 8 By pass Valve 3020810 1 9 Electronic Timer 1600500 1 10 Rotary Switch 3030555 1 11 Terminal Block 3031460...

Страница 9: ...EACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THI...

Отзывы: